Description
1. Product Presentation
The disposable electrosurgical pencil Ref. F4390/A is the consumable your operating theatre team needs for open surgery: clean cutting, reliable haemostasis and the peace of mind of a sterile, single-use product, ready to use in every procedure. Foot pedal activation frees the surgeon’s hands, allowing full control of cutting and coagulation with the foot, without releasing the instrument or diverting attention from the operative field.
Presented in a box of 50 sterile units with a factory-mounted F4048 needle, it is the ideal option for hospitals, private clinics, ambulatory surgery centres and purchasing groups seeking the best balance between cost per procedure, safety, constant supply and performance in every intervention.
2. Technical explanation of the equipment and procedure
The foot-control electrosurgical pencil is a monopolar electrosurgery pencil: the radiofrequency current generated by the generator (ESU) travels through the cable to the active electrode (the F4048 needle) and concentrates at the point of contact with the tissue, producing the desired surgical effect — cut, coagulation or blend — and returning through the patient’s neutral (dispersive) plate.
- Foot pedal activation: cutting and coagulation control with the foot, without manual buttons on the handle, ideal for prolonged manoeuvres and precision dissections.
- F4048 needle: stainless steel needle electrode, ideal for precision cutting and fine dissection with minimal lateral thermal damage; shaft of 2.38 mm (3/32″), standard diameter for pencil electrodes, compatible with the receptacle of most pencils in the sector and with the replaceable electrodes of the F404x family.
- 320 cm cable: wide reach over the surgical field without tension, designed to position the table and move the pencil freely.
- 3.2 mm connector: standard monopolar plug for quick and secure connection to the generator outlet (adapters F4835–F4838 for other standards).
- Sterile single-use: eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
| Product type | Disposable single-use electrosurgical pencil (electrosurgical unit) |
| System | Monopolar, cutting and coagulation |
| Activation | Foot pedal control (hands-free) |
| Electrode | Stainless steel needle F4048 (removable) |
| Shaft diameter | 2.38 mm (3/32″) |
| Cable length | 320 cm |
| Connector | 3.2 mm monopolar plug |
| Sterility | Sterile, single-use disposable |
| Presentation | Box of 50 units |
| Reference | F4390/A |
Compatibility: the 3.2 mm connector fits the standard monopolar outlet of most electrosurgical generators on the market. For generators with a different connection standard (Valleylab, 4 mm, Erbe), please refer to the variants with specific connector (e.g. F4390/4M) or the reusable adapters from the F4835–F4838 range.
4. Equivalences and Cross-References
The reference F4390/A is a distribution code proprietary to Cahnos. There is no equivalence table validated by the manufacturer covering this reference; the following rows are functional comparisons verified against official catalogues and regulatory databases (GUDID/FDA), not 1:1 equivalents.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Bovie (Aspen Surgical) | Electrosurgical Foot Control Pencil with Needle (disposable foot-control pencil with needle electrode, box of 50 units) | ESP7N | Comparable by category (not interchangeable 1:1) | Same product type: disposable foot-control pencil, monopolar, sterile, single-use, with needle electrode and presented in a box of 50 units. Differs: the connector standard (1-pin / 3-pin Valleylab type vs. 3.2 mm plug), cable length and electrode designation. Code and attributes verified in GUDID/FDA (model ESP7N, Aspen Surgical Products, Inc.). |
| Medline (Medline Industries) | Pencil, Cautery, Foot Switch, PTFE Blade (foot switch cauterisation pencil) | ESFS3002 | Comparable by category (not interchangeable 1:1) | Disposable cauterisation pencil with foot pedal activation and mounted electrode, box of 50 units. Differs: blade electrode with PTFE coating vs. the F4048 stainless steel needle, in addition to cable length and connector standard. Code and attributes verified in GUDID/FDA (model ESFS3002, Medline Industries, Inc.). |
There is no equivalence table validated by the manufacturer; consult with the technical department before using in a tender. For a 1:1 replacement, always verify field by field: electrode type (needle vs. blade or sphere), shaft diameter (2.38 mm / 3/32″), cable length, type of installed generator connector (3.2 mm vs. 4 mm or Valleylab), sterility and presentation.
5. Selection tips and variants of interest
Verify your generator connector: this pencil features a 3.2 mm monopolar connector; if your ESU is of a different standard (Valleylab, 4 mm, Erbe), choose the variant with specific connector F4390/4M (4 mm plug) or use the reusable adapters from the F4835–F4838 range.
Choose the electrode geometry according to the technique: the F4048 needle is ideal for precision cutting and fine dissection; the same family is completed with the blade F4046 (F4390), the sphere F4044 (F4390/P), the blade F4050 (F4390/L), the needle F4052 (F4390/AL) and the sphere F4067 (F4390/PL), all with 2.38 mm shaft and 320 cm cable; the F4390/5 variant incorporates a 500 cm cable for maximum reach.
Recommended kits and accessories: F4390/H and F4390/5H (with sterile sleeve F4545) and F4390/75 and F4390/5-75 (with tip cleaner F7520); the F4545 sleeve allows fixing the pencil to the field and the F7520 cleaner maintains electrode performance by removing eschar during the procedure.
Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.





Reviews