The disposable electrosurgery electrode Ref. F4053S/TEF is the reference active tip when precise cut and coagulation with maximum protection of healthy tissue is required. Its 100 mm blade is coated with non-stick PTFE (Teflon) and features a 95 mm insulating sleeve that limits the active area to the tip, ideal for working in deep surgical fields, cavities and areas with restricted visibility. It is supplied in a box of 24 units single-use, the most hygienic and cost-effective solution for hospitals, clinics and major ambulatory surgery centres, with stock available for immediate B2B supply.
2. Technical explanation and operation
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil to the active electrode —this F4053S/TEF blade—, which concentrates the energy at the point of contact with the tissue; the circuit is closed via the neutral (dispersive) pad placed on the patient. Depending on the selected waveform, the predominant effect is cut, coagulation or blended.
- PTFE (Teflon) coating: non-stick effect that prevents tissue from sticking to the tip, reduces carbonisation and eschar formation, maintains conductivity and avoids interruptions to clean the tip during the procedure.
- 95 mm insulating sleeve: insulates virtually the entire blade shaft, concentrating energy at the active end and protecting adjacent tissues from accidental contact in deep access sites.
- 2.38 mm (3/32″) shaft: universal standard fitting, compatible with virtually all pencils and electrosurgical units on the market (Valleylab-type connector and compatible), without the need for adapters.
- Disposable and sterile: single-use, eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
3. Technical Specifications
| Reference / SKU | F4053S/TEF |
| Product type | Disposable monopolar electrosurgery electrode, blade tip with insulating sleeve |
| Blade length | 100 mm |
| Insulating sleeve | 95 mm |
| Coating | Non-stick Teflon (PTFE) on the active zone |
| Material | Surgical-grade stainless steel with Teflon coating |
| Tip shape | Blade (blade) |
| Shaft diameter | 2.38 mm (3/32″) — universal standard |
| Compatibility | Pencils and electrosurgical units with 2.38 mm (3/32″) Valleylab-type receptacle and compatible (ConMed, Bovie, Erbe via adapter) |
| Type of use | Disposable, single-use |
| Sterility | Individual sterile packaging |
| Latex | Latex-free |
| Presentation | Box of 24 units |
Variants of the same family (Teflon coating, 2.38 mm shaft, box of 24 units):
| Reference | Length | Shape |
| F4044/TEF | 70 mm | Sphere Ø 4 mm |
| F4046/TEF | 70 mm | Blade |
| F4046S/TEF | 70 mm (65 mm sleeve) | Blade |
| F4048/TEF | 70 mm | Needle |
| F4050/TEF | 150 mm | Blade |
| F4050S/TEF | 150 mm (sleeve 145 mm) | Blade with sleeve |
| F4052/TEF | 150 mm | Needle |
| F4053/TEF | 100 mm | Blade without sleeve |
| F4053S/TEF (this product) | 100 mm (95 mm sleeve) | Blade with sleeve |
| F4067/TEF | 150 mm | Sphere Ø 4 mm |
4. Equivalences and Cross-References
No official cross-reference table from the manufacturer validating an exact 1:1 equivalence of this electrode with those of other brands has been found in public sources. The following rows are functional comparisons verified against official manufacturer catalogues and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not 1:1 interchangeable without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Prima Medical (United Kingdom) | NonStick™ blade electrode, 100 mm, shielded tip (PTFE-coated) | PMS 2926 (pack of 10) | Comparable by category (not interchangeable 1:1) | Same blade length (100 mm) and non-stick PTFE coating with shielded tip, function equivalent to the insulating sleeve; differ in presentation (pack of 10 vs 24) and manufacturer. Code verified in the brand’s official distribution catalogue (Eurosurgical). |
| Prima Medical (United Kingdom) | NonStick™ blade electrode, 100 mm (PTFE-coated, without shielded tip) | PMS 2925 (pack of 10) | Comparable by category (not interchangeable 1:1) | Same length (100 mm) and PTFE coating; differ in the absence of sleeve/shielded tip and presentation (pack of 10). Code verified in the brand’s official catalogue. |
| Aspen Surgical / Bovie (USA) | Resistick II™ Coated Extended Blade Electrode 4″ (10.16 cm) | ES55T (box of 12) | Comparable by category (not interchangeable 1:1) | Sterile disposable electrode with PTFE coating and extended shaft insulation (function equivalent to the sleeve); very similar length (101.6 mm vs 100 mm) and 3/32″ shaft (≈2.3 mm). Differ in presentation (12 vs 24). Code and attributes verified in GUDID/FDA (class II, sterile). |
| Aspen Surgical / Bovie (USA) | Resistick II™ Coated Standard Blade Electrode 2.75″ (6.98 cm) | ES01T (box of 12) | Comparable by category (not interchangeable 1:1) | Same non-stick PTFE concept for pencils with 3/32″ receptacle; substantially different length (≈70 mm vs 100 mm) and does not include an insulating sleeve. Code and attributes verified in GUDID/FDA and manufacturer’s catalogue. |
There is no equivalence table validated by the manufacturer that cross-references the F4053S/TEF reference with codes from other brands; consult the technical department before use in tenders. Before any substitution, check field by field: blade length (100 mm), insulating sleeve (95 mm), shaft diameter (2.38 mm / 3/32″), coating (Teflon/PTFE), sterility and presentation. The third-party codes cited have been verified in public sources and correspond to electrodes of the same category, not certified 1:1 equivalents.
5. Selection tips and variants of interest
Choose the tip geometry according to the surgical technique: the 100 mm blade with 95 mm sleeve of the F4053S/TEF is ideal for electrosection in medium access sites with protection of adjacent tissues. If you need more reach, the reference F4050S/TEF offers the same configuration with a 150 mm blade and 145 mm sleeve; to work without insulation, the F4053/TEF maintains the 100 mm blade without sleeve at a lower cost. For contact coagulation, the Teflon family is completed with the spheres F4044/TEF (70 mm) and F4067/TEF (150 mm), and for precise point haemostasis, with the needles F4048/TEF (70 mm) and F4052/TEF (150 mm). Always verify that your pencil accepts a 2.38 mm (3/32″) shaft: virtually all electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible) accept it. This is a single-use product: do not re-sterilise or reuse. For institutional volumes, supply agreements or tenders, consult our technical-commercial department.