Description
1. Product Presentation
The disposable electrosurgical unit Ref. F4797/AS from FIAB is a single-use monopolar electrosurgical pencil with dual push-button manual control, designed for procedures requiring precision, hygiene and safety in every intervention. It incorporates the F4048/S needle electrode with insulating sleeve, 320 cm cable, 2.38 mm shaft and 3-pin Valleylab-type connector, ensuring compatibility with the vast majority of electrosurgical generators found in operating theatres, hospitals, clinics and ambulatory surgery centres. Its presentation in a box of 50 units with individual sterile packaging optimises logistics, stock control and cost per procedure for institutional purchasing.
2. Technical explanation of the equipment and procedure
The electrosurgical unit acts as the active electrode of a monopolar electrosurgery system: the pencil connects to the generator (ESU) via the three-pin Valleylab-type connector and the circuit is completed through the dispersive (neutral) plate placed on the patient. The two push buttons on the handle allow activation of the cut (CUT) and coagulation (COAG) functions without the need for a foot pedal, giving the surgeon ergonomic, precise and direct control during dissection and haemostasis.
The F4048/S needle electrode concentrates high-frequency energy into a fine tip, making it particularly effective for pinpoint incisions and precise dissection with minimal carbonisation of adjacent tissue; its insulating sleeve protects collateral tissues during the procedure. The 2.38 mm shaft ensures rigidity and stability in the handle, while the 320 cm cable provides ample freedom of movement around the operating table. Being a sterile single-use device, the risk of cross-contamination and the costs of cleaning and re-sterilisation are eliminated.
3. Technical Specifications
Technical features of the FIAB F4797/AS electrosurgical unit:
| Characteristic | Value |
|---|---|
| Reference FIAB | F4797/AS |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Disposable electrosurgical pencil (electrosurgical unit) with push buttons |
| Control | Double push button: cut (CUT) and coagulation (COAG) |
| Included electrode | Needle F4048/S with insulating sleeve |
| Electrode size | Ø 2.38 mm |
| Cable length | 320 cm |
| Connector | Valleylab (3 pins) |
| Sterility | Sterile, single-use |
| Packaging | Box of 50 individual units |
| Units per box (web) | 50 |
Variants of the same family of FIAB pencils with push button, 2.38 mm shaft and Valleylab connector:
| Reference | Electrode | Cable | Connector |
|---|---|---|---|
| F4797 | Blade F4046 | 320 cm | Valleylab |
| F4797/A | Needle F4048 | 320 cm | Valleylab |
| F4797/5A | Needle F4048 | 500 cm | Valleylab |
| F4797/AL | F4052 needle electrode | 320 cm | Valleylab |
| F4797/L | Blade F4050 | 320 cm | Valleylab |
| F4797/P | Sphere F4044 | 320 cm | Valleylab |
| F4797/PL | Sphere F4067 | 320 cm | Valleylab |
| F4797/5 | Blade F4046 | 500 cm | Valleylab |
| F4797/SE | Blade F4046/F4050 with smoke evacuator | 300 cm | Valleylab (box of 10 units) |
4. Equivalences and Cross-References
No official cross-reference table from the manufacturer has been found in public sources to validate an exact 1:1 equivalence of this pencil with those of other brands. The following references are functional comparisons verified against each manufacturer’s public documentation (official catalogues and authorised distribution) and should be treated as comparable at category level, not interchangeable 1:1 without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level |
|---|---|---|---|
| Medtronic / Valleylab | Disposable push-button pencil with needle, cable ≈3 m | E2516H-DA | Comparable by category (not interchangeable 1:1) |
| Medtronic / Valleylab | Disposable push-button pencil with blade | E2516 | Comparable by category (not interchangeable 1:1) |
| Erbe | Disposable 2-button pencil, cable 3 m | 20190-107 | Comparable by category (not interchangeable 1:1) |
| ConMed | GoldLine Push Button, blade, cable 10 ft | 130309A | Comparable by category (not interchangeable 1:1) |
| Bovie | Disposable push-button pencil with needle | ESP1N | Comparable by category (not interchangeable 1:1) |
Before any substitution, check field by field: electrode geometry and length, type of insulating sleeve, shaft diameter (3/32″ ≈ 2.4 mm), connector type (3-pin Valleylab), cable length, presentation and regulatory classification of the actual product.
5. Selection tips and variants of interest
The choice of electrode determines the effect on tissue: the F4048/S needle of this pencil, with insulating sleeve, provides maximum precision in pinpoint incisions and haemostasis of small bleeding points while protecting adjacent tissues; the F4046 blade (F4797) is the versatile option for cutting; the F4050 blade (F4797/L) offers very similar behaviour; and the F4044/F4067 spheres (F4797/P, F4797/PL) are indicated for coagulation of large surfaces. If more reach around the operating table is needed, request the F4797/5A variant (F4048 needle with 500 cm cable); and for procedures with surgical smoke generation, the F4797/SE version incorporates a smoke evacuator.
Always verify that your electrosurgical generator has a 3-pin Valleylab socket: if you use an Erbe generator, request the direct connection variant (/ERB) or the F4831, F4832 and F4833 adapters for Berchtold, Martin and Erbe generators. As complementary accessories from the electrosurgery catalogue, the sterile sheath F4545 and the sterile tip cleaner F7520 are recommended to maintain electrode performance during the procedure. Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.




Reviews