Description
Foot-controlled electrosurgical unit with F4044 ball: hands-free precision in open surgery
The disposable electrosurgical unit Ref. F4390/P is the consumable your operating theatre team needs for open surgery: clean cutting, reliable haemostasis and the peace of mind of a sterile single-use product, ready to use in every procedure. Foot pedal activation frees the surgeon’s hands, who maintains full control of cutting and coagulation with the foot, without letting go of the instrument or diverting attention from the field.
Presented in a box of 50 sterile units with factory-mounted F4044 ball, it is the ideal option for hospitals, private clinics, ambulatory surgery centres and purchasing groups seeking the best balance between cost per procedure, safety, constant supply and performance in every intervention.
Technical explanation: monopolar electrosurgery pencil
The foot-controlled electrosurgical unit is a monopolar electrosurgery pencil: the radiofrequency current generated by the generator (ESU) travels through the cable to the active electrode (the F4044 ball) and concentrates at the point of contact with the tissue, producing the desired surgical effect —cutting, coagulation or mixed— and returning through the patient’s neutral (dispersive) plate.
- Foot pedal activation: control of cutting and coagulation with the foot, without manual buttons on the handle, ideal for prolonged procedures and precise dissections.
- F4044 ball: Ø 4 mm ball electrode in stainless steel (length 70 mm), suitable for contact coagulation and controlled fulguration on delicate surfaces.
- 2.38 mm shaft: standard diameter in pencil electrodes (3/32″), compatible with the housing of most pencils in the sector and with the F404x replaceable electrode family.
- 320 cm cable: wide reach over the surgical field without tension, designed to distribute the table and move the pencil with freedom.
- 3.2 mm connector: standard monopolar plug for quick and secure connection to the generator socket (F4835–F4838 adapters for other standards).
- Sterile single-use: eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
Technical specifications
| Product type | Disposable electrosurgery pencil (electrosurgical unit), single-use |
| System | Monopolar, cut and coagulation |
| Activation | Foot pedal control (hands-free) |
| Electrode | Stainless steel F4044 ball, Ø 4 mm ball, length 70 mm |
| Shaft diameter | 2.38 mm (3/32″) |
| Cable length | 320 cm |
| Connector | 3.2 mm monopolar plug |
| Sterility | Sterile, single-use disposable |
| Presentation | Box of 50 units |
| Reference | F4390/P |
Compatibility: the 3.2 mm connector fits the standard monopolar socket of most electrosurgical generators on the market. For generators with another connection standard (Valleylab, 4 mm, Erbe), consult the variants with specific connector (e.g. F4390/4M) or the reusable adapters from the F4835–F4838 range.
Equivalences and cross-references
The reference F4390/P is a distribution code proprietary to Cahnos. There is no equivalence table validated by the manufacturer covering this reference; the following rows are functional comparisons verified against official catalogues and regulatory databases (GUDID/FDA), not 1:1 equivalences.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Bovie (Aspen Surgical) | Electrosurgical Foot Control Pencil (disposable monopolar pencil, box of 50 units) | ESP7 | Comparable by category (not interchangeable 1:1) | Same product type: disposable foot-controlled monopolar pencil, single-use and presented in a box of 50 units. Differs: the mounted electrode (stainless steel blade versus the Ø 4 mm F4044 ball), cable length and connector standard (3-pin Valleylab type versus 3.2 mm plug). Code and attributes verified in GUDID/FDA (model ESP7, Aspen Surgical Products, Inc.). |
| Medline (Medline Industries) | Pencil, Cautery, Foot Switch, PTFE Blade | ESFS3002 | Comparable by category (not interchangeable 1:1) | Disposable cauterisation pencil with foot switch and mounted electrode, box of 50 units. Differs: blade electrode with PTFE coating versus the stainless steel F4044 ball, in addition to cable length and connector. Code and attributes verified in GUDID/FDA (model ESFS3002, Medline Industries, Inc.). |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. For a 1:1 substitution, always verify field by field: electrode type (Ø 4 mm ball versus blade or needle), shaft diameter (2.38 mm / 3/32″), cable length, connector type of the installed generator (3.2 mm versus 4 mm or Valleylab), sterility and presentation.
Selection tips and variants of interest
Check your generator connector: this pencil has a 3.2 mm monopolar connector; if your ESU is of another standard (Valleylab, 4 mm, Erbe), choose the variant with specific connector F4390/4M (4 mm plug) or use the reusable adapters from the range (F4835–F4838).
Choose the electrode geometry according to the technique: the F4044 ball is ideal for contact coagulation and fulguration; for cutting and dissection, the same family is completed with the F4046 blade (F4390), the F4048 needle (F4390/A), the F4050 blade (F4390/L), the F4052 needle (F4390/AL) and the F4067 ball (F4390/PL), all with 2.38 mm shaft and 320 cm cable; the F4390/5 variant incorporates a 500 cm cable for maximum reach.
Recommended kits and accessories: F4390/H and F4390/5H (with sterile sheath F4545) and F4390/75 and F4390/5-75 (with tip cleaner F7520); the F4545 sheath allows fixing the pencil to the field and the F7520 cleaner maintains electrode performance by removing eschar during the procedure.
Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.





Reviews