Description
1. Product Presentation
The disposable electrosurgery pencil FIAB Ref. F4390/4M is the consumable that your operating theatre team needs for open surgery: clean cutting, reliable haemostasis and the peace of mind of a sterile single-use product, ready to use in every procedure. Pedal activation frees the surgeon’s hands, who maintains full control of cutting and coagulation with the foot, without releasing the instrument or distracting attention from the operative field.
Presented in a box of 50 sterile units with F4046 blade electrode mounted, it is the ideal option for hospitals, private clinics, ambulatory surgery centres and purchasing centres seeking the best balance between cost per procedure, safety, constant supply and performance in each intervention. This model features a 4 mm monopolar PLUG connector, designed for generators with a standard 4 mm socket.
2. Technical explanation of the equipment and procedure
The pedal-controlled electrosurgical unit is a monopolar electrosurgery pencil: the radiofrequency current generated by the generator (ESU) travels through the cable to the active electrode (the F4046 blade) and concentrates at the point of contact with the tissue, producing the desired surgical effect —cutting, coagulation or mixed— and returning through the patient’s neutral (dispersive) plate.
- Pedal activation: control of cutting and coagulation with the foot, without manual buttons on the handle; ideal for prolonged procedures and precision dissections.
- F4046 (BLADE) electrode: stainless steel blade of removable type, with a stable edge for repeated dissection and coagulation; shaft of 2.38 mm (3/32″), standard diameter compatible with the F404x family of replaceable electrodes.
- 320 cm cable: wide reach over the surgical field without tension, designed to allow the table to be laid out and the pencil to be moved freely.
- 4 mm PLUG connector: quick and secure monopolar connection for generators with a standard 4 mm socket.
- Sterile single-use: eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Product type | Disposable electrosurgery pencil (electrosurgical unit), single-use |
| System | Monopolar, cut and coagulation |
| Activation | Foot pedal control (hands-free) |
| Electrode | F4046 (BLADE) stainless steel blade, removable |
| Shaft diameter | 2.38 mm (3/32″) |
| Cable length | 320 cm |
| Connector | 4 mm monopolar plug |
| Sterility | Sterile, single-use disposable |
| Reference FIAB | F4390/4M |
|---|---|
| Packaging | Box of 50 individual units |
| Units per box (web) | 50 |
Compatibility: the 4 mm connector fits the monopolar socket of electrosurgical generators with a 4 mm standard. For generators with another connection standard (3.2 mm, Valleylab, Erbe), consult the variants with a specific connector or the reusable adapters from the manufacturer’s range.
F4390 family · disposable pedal-controlled pencils (shaft Ø 2.38 mm):
| Reference | Cable | Connector | Electrode |
|---|---|---|---|
| F4390 | 320 cm | 3.2 mm | Blade F4046 |
| F4390/5 | 500 cm | 3.2 mm | Blade F4046 |
| F4390/A | 320 cm | 3.2 mm | Needle F4048 |
| F4390/P | 320 cm | 3.2 mm | F4044 ball electrode (Ø 4 mm) |
| F4390/L | 320 cm | 3.2 mm | Blade F4050 |
| F4390/AL | 320 cm | 3.2 mm | F4052 needle electrode |
| F4390/PL | 320 cm | 3.2 mm | Sphere F4067 |
| F4390/4M (this product) | 320 cm | 4 mm plug | Blade F4046 |
4. Equivalences and Cross-References
The reference F4390/4M corresponds to the manufacturer’s code FIAB for the disposable pedal-controlled pencil with 4 mm connector, 320 cm cable and F4046 blade electrode. There is no 1:1 equivalence table validated by the manufacturer covering this reference; the following references are functional comparisons by product category, verified against official catalogues and regulatory databases (GUDID/FDA), not interchangeable 1:1 equivalents.
| Manufacturer / Brand | Family / Model | Code / SKU |
|---|---|---|
| Aspen Surgical (Bovie) | Disposable pedal-controlled pencil with blade electrode (box of 50 units) | ESP7 |
| Medline Industries | Cauterisation pencil with pedal activation and mounted electrode | ESFS3002 |
Note: these references are comparable by category (disposable monopolar pedal-controlled pencil, sterile, single-use, with blade electrode and presentation of 50 units), but they differ in the connector standard (1 pin or Valleylab type versus the 4 mm plug), cable length and electrode designation. For a 1:1 substitution, always verify electrode type, shaft diameter, cable length, connector standard of the installed generator and presentation.
5. Selection tips and variants of interest
Check your generator’s connector: this pencil features a 4 mm monopolar connector; if your ESU is of another standard (3.2 mm, Valleylab, Erbe), choose the variant from the same family with the appropriate connector (e.g. F4390 with 3.2 mm plug) or use the reusable adapters from the FIAB range.
Choose the electrode geometry according to the technique: the F4046 blade is ideal for general cutting and dissection in open surgery; the same family is completed with the F4048 needle (F4390/A), the F4044 sphere (F4390/P), the F4050 blade (F4390/L), the F4052 needle (F4390/AL) and the F4067 sphere (F4390/PL), all with a 2.38 mm shaft and 320 cm cable; the F4390/5 variant incorporates a 500 cm cable for maximum reach.
As complementary accessories from the electrosurgery catalogue, the sterile sheath F4545 is recommended to secure the pencil to the surgical field, and the tip cleaner F7520 to maintain electrode performance by removing eschar during the procedure. Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.





Reviews