Description
1. Commercial Introduction
The flexible steel-rubber neutral plate Ref. 30556 is the reusable return electrode that your monopolar electrosurgical unit needs to work with full safety. With dimensions of 120 x 210 mm and a bipartite configuration of 2 parts, it offers a large contact surface that adapts to the patient’s contour and evenly distributes the high-frequency return current. Manufactured (Italy), it is reused between patients after sterilisation in an autoclave, which reduces the cost per procedure and medical waste compared with disposable plates. It is the standard plate for the Diatermo MB series and is supplied without a cable: it must be combined with the plate cable Ref. 30560, purchased separately.
2. Technical Explanation
In any procedure with a monopolar electrosurgical unit, the high-frequency current that leaves the active electrode (handle or pencil) must return to the generator through a controlled path of low current density. The neutral plate or dispersive electrode fulfils this function: placed on a well-irrigated muscular area away from the surgical field, it collects the return current uniformly and avoids energy concentrations that could damage tissue. This flexible steel-rubber plate of 2 parts adapts to the patient’s anatomy, ensuring broad and homogeneous contact. Being autoclavable, it can be sterilised after each use following the manufacturer’s indications, which makes it especially suitable for environments where material reuse is prioritised. It is recommended to always apply it on dry, intact, hairless skin, verifying correct skin-plate contact before activating the equipment.
3. Technical Specifications
The plate is presented as a metallic return electrode of flexible steel-rubber, reusable and autoclavable, with a bipartite configuration (2 parts), without connection cable. For its use, the plate cable Ref. 30560 is required (not included).
| Characteristic | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 30556 |
| Measurements | 120 x 210 mm |
| Plate type | Flexible steel-rubber, bipartite (2 parts) |
| Cable | Without cable; requires the plate cable Ref. 30560 (not included) |
| Sterilisation | Autoclavable |
| Use | Reusable |
| Compatibility | All diatermo except Refs. 30516 and 30625 |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | II B |
| EAN | 8033638324660 |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| 30556 | Reusable steel-rubber plate 120 x 210 mm, 2 parts, autoclavable (uses cable 30560) | 1 pc |
| 30555 | Reusable steel-rubber plate (uses cable 30560) | 1 pc |
| 30560 | Cable for reusable plates (30555, 30556, 30566) | 1 pc |
4. Equivalences and Cross-References
No official equivalence table validated by the manufacturer has been found in reliable sources that cross-references reference 30556 with identical codes from other brands; any substitution with neutral plates from other manufacturers must be validated field by field (measurements, active surface, plate type and connector compatibility with the generator’s monitoring system) with the technical department of Cahnos. Within the range itself, Ref. 30555 is the flexible steel-rubber plate of the same family (120 x 210 mm, requires cable 30560), and cable Ref. 30560 serves plates 30555, 30556 and 30566. As complementary alternatives of the ecosystem, the reusable metallic plate Ref. 30566 (requires cable 30560), the bipartite rubber REM plate Ref. 30574 (requires cable 30575) and the flat plate with cable Ref. 30564 are listed.
5. Selection tips and variants of interest
Verify that your electrosurgical unit is compatible with this plate: it is indicated for all its diatermo except Refs. 30516 and 30625, and appears as a standard accessory in equipment of the Diatermo MB series (for example, models with touch screen). To connect it to the generator you will need the reusable plate cable Ref. 30560, which must be purchased separately. If you prefer a plate with the cable already incorporated, consider the flat plate Ref. 30564 (16 x 12 cm); if your generator has a REM-type return monitoring system and you are looking for a bipartite rubber option, consider Ref. 30574; for a more rigid return, the metallic plate Ref. 30566 is an alternative from the same reusable family. After each use, clean the conductive surface according to the manufacturer’s indications, sterilise it in an autoclave and visually inspect it before each procedure, replacing it in the event of any crack, deformation or loss of conductivity. For volume orders or B2B hospital supply conditions, consult the technical-commercial team of Cahnos.