The flexible rubber electrosurgical plate (Reference 30562) is the reusable return electrode that your monopolar electrosurgical unit needs to work with complete safety. Measuring 15 x 8 cm with a built-in 4.5 m cable, it offers a ready-to-use solution: it connects directly to the generator without the need for additional cables and is reused between patients after proper cleaning and sterilisation. Its compact, flexible format makes it the usual choice for minor surgery practices, operating theatres, ambulatory surgery centres and veterinary clinics looking to reduce the cost per procedure and medical waste compared with disposable plates.
2. Technical explanation
In any monopolar electrosurgical procedure, the high-frequency current that leaves the active electrode (handle or pencil) must return to the generator via a low current-density path. The neutral plate or dispersive electrode collects this return current in a controlled manner: if the skin-plate contact is incorrect or the surface is insufficient, the current density at the return point increases, and with it the risk of thermal burn to the patient. This flexible conductive rubber plate ensures a uniform contact surface, adapting to the body contour and reducing the likelihood of energy concentrations. Being autoclavable, it can be sterilised after each use following the manufacturer’s instructions, making it especially suitable for environments where material reuse is prioritised. It is recommended to always apply it to dry, intact, hair-free skin, on a well-perfused muscular area away from the surgical site, verifying proper contact before activating the equipment.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 30562 |
| Product type | Reusable flexible rubber electrosurgical plate (return electrode) |
| Plate dimensions | 15 x 8 cm |
| Cable | Integrated, 4.5 m |
| Sterilisation | Autoclavable |
| Use | Reusable |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | II B |
| CND | Z12010980 |
| EAN | 8023279305623 |
4. Equivalences and Cross-References
Reference 30562 (SKU Cahnos GM30562) uniquely identifies this flexible rubber plate with cable. No reliable sources have been found for an official equivalence table validated by the manufacturer that cross-references this reference with 1:1 codes from other brands; any substitution with neutral plates from other manufacturers must be validated field by field (measurements, active surface, connector type and compatibility with the generator’s monitoring system) with the technical department of Cahnos. Within the return electrode range itself, the following complementary or functionally comparable references are listed:
| Reference | Product | Related items |
|---|---|---|
| 30565 (GM30565) | Flexible rubber plate 25 x 15 cm with 4.5 m cable | Larger surface variant, same family |
| 30564 (GM30564) | Flat neutral plate 16 x 12 cm with cable | Flat alternative with cable from the same range |
| 30566 (GM30566) | Reusable metal neutral plate without cable (requires cable 30560) | Non-flexible reusable alternative |
| 30560 (GM30560) | Cable for reusable plates (30555, 30556, 30566) | Complementary accessory |
| 30574 | Two-part rubber REM plate 20 x 15 cm without cable (requires cable 30575) | Comparable by function, with REM system |
This plate is listed as a standard accessory in the documentation for the Diatermo MB series electrosurgical units (e.g. Diatermo MB 120F, Ref. 30631, and MB 200F, Ref. 30633), so it is advisable to always verify connector compatibility with the generator installed at your facility.
5. Selection tips and variants of interest
Check compatibility with your electrosurgical unit: this plate with built-in 4.5 m cable is designed for the electrosurgical range, so it is advisable to verify the connector on your generator before purchase. If you prefer a larger plate for adult patients or prolonged procedures, consider Ref. 30565 (25 x 15 cm); for equipment with a REM-type return monitoring system, consider the bipartite plate Ref. 30574; if you are looking for a more rigid option, the metal plate Ref. 30566 (with cable 30560) is a reusable alternative from the same family. Maintenance: after each use, clean the conductive surface according to the manufacturer’s instructions, sterilise it in an autoclave and visually inspect it before each procedure, replacing it if there are any cracks, cuts or loss of conductivity. For volume orders or B2B hospital supply conditions, consult the technical-commercial team at Cahnos.