Description
Connection cable for reusable neutral plate FIAB F7924
We present the original FIAB connection cable for reusable neutral plates, an essential reference to complete the monopolar circuit of your electrosurgery with maximum reliability. With a length of 500 cm and a 6.3 mm mono jack connector, this cable is specifically indicated for ERBE electrosurgical generators of the ACC, ICC, VIO and T series, and allows the return plate to be reused in multiple procedures after cleaning.
It is the usual choice in operating theatres, minor surgery clinics, dermatology, dentistry and veterinary clinics that work with ERBE equipment and wish to reduce medical waste and the recurring cost of single-use electrodes, while maintaining a safe and stable return contact.
Technical explanation
In monopolar electrosurgery, the high-frequency current exits through the active electrode (pencil), passes through the patient’s tissue and must return to the generator via a low current density path: the neutral plate or return electrode. The quality of that return path depends both on the plate and on the cable that connects it to the electrosurgical unit.
This FIAB F7924 cable guarantees that connection with a 6.3 mm mono jack connector, the configuration used by ERBE equipment of the ACC, ICC, VIO and T series. When working with reusable neutral plates equipped with a 4 mm socket, the plate-cable assembly ensures a low and stable contact impedance, an essential condition to avoid current density concentrations that could lead to patient burns. It is a reusable accessory: it must be cleaned after each use, visually inspected (for cuts, cracks or deterioration of the insulation) and its continuity periodically verified before each procedure.
Technical specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7924 |
| Brand | FIAB (FIAB SpA, Vicchio, Florence, Italy) |
| Product type | Connection cable for reusable neutral plate |
| Length | 500 cm |
| Connector | 6.3 mm mono jack |
| Compatibility | ERBE electrosurgical unit: series ACC, ICC, VIO and T |
| Type of use | Reusable |
| Packaging | Single unit |
| Units per box (web) | 1 |
Available references
| Reference | Description | Length |
|---|---|---|
| F7924 | Special 6.3 mm mono jack cable for ERBE (ACC, ICC, VIO, T) | 500 cm |
Equivalences and cross-references
This cable belongs to the FIAB range of connection cables for reusable neutral plates. Complete with these references from the same commercial family, depending on the generator connector installed at your facility:
| Reference | Description |
|---|---|
| F7922 | Universal cable, 6.3 mm mono jack connector, 500 cm |
| F7922/4 | Cable with 4 mm plug, 500 cm |
| F7922/24 | Cable with double 4 mm plug, 500 cm |
| F7923 | Valleylab type cable (ESU with REM), 500 cm |
| F7923/F | Valleylab type cable (ESU without REM), 500 cm |
| F7924 | Special 6.3 mm mono jack cable for ERBE (ACC, ICC, VIO, T), 500 cm |
This cable is intended for use with the reusable silicone neutral plates of the same range: the F7930 plate (200 x 150 mm, 250 cm², with REM system and 4 mm socket) and the F7915 plate (without REM system, same 4 mm socket). There is no official equivalence table validated by the manufacturer with cables from other brands; before any replacement, confirm with the technical department the compatibility of the connector with your generator.
Selection tips and variants of interest
- Check your equipment connector: the F7924 reference is valid exclusively for ERBE generators with a 6.3 mm socket of the ACC, ICC, VIO and T series. If your equipment uses a Valleylab-type connector, consider refs. F7923 (with REM) or F7923/F (without REM); if it uses a single or double 4 mm plug, refs. F7922/4 and F7922/24.
- Compatible plate: use it with reusable FIAB plates with a 4 mm socket (F7930 with REM or F7915 without REM) to ensure a stable return contact.
- Maintenance: clean the cable after each use with the products indicated by the manufacturer, dry it completely and avoid sharp bends; check the insulation and continuity before each procedure and replace it at any sign of degradation.
- Institutional purchases: for operating theatre fittings or volume orders with special B2B conditions, consult our technical-commercial department.