Description
Neonatal return plate for safe electrosurgery
The neonatal electrosurgical foam plate Ref. F7805N is the essential neutral return electrode to complete the monopolar circuit of any high-frequency electrosurgery equipment when operating on neonatal or very low birth weight patients. With a compact backing of 88 x 74 mm and 36 cm² of active surface, it offers the optimal balance between contact area and adaptation to the newborn’s anatomy, minimising current density in the return zone and, with it, the risk of thermal burn.
It is presented in a box of 25 units with individual heat-sealed packaging that protects the conductive hydrogel until the moment of use: the consumption format chosen by hospitals, clinics and neonatology units that need permanent stock, batch traceability and predictable cost per procedure.
How the return plate works and why it is important
In any procedure with a monopolar electrosurgical unit, the high-frequency current leaves through the active electrode (handle or pencil), passes through the patient’s tissue and must return to the generator through a low current density path. The neutral plate collects that current in a controlled manner: if the contact is not correct or the surface is insufficient, the current density at the return point increases and with it the risk of burn to the patient.
This plate is constructed with a polyethylene foam backing (PE foam) and conductive hydrogel adhesive, which favours adaptation to the neonate’s body contour and uniform contact on the skin. It belongs to the series without REM system: it does not activate the return monitoring control (REM) of the generator, so it must be used with conventional equipment without the requirement of a split plate, always selecting the lowest possible energy level. As it is a plate without cable with TAB (tabs) connection, the professional must use a reusable plate cable (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for Erbe), a configuration that reduces the cost per procedure and facilitates warehouse management.
Technical specifications
| Reference / SKU | F7805N |
| Product type | Disposable return plate (electrode) for monopolar electrosurgery |
| Population | Neonatal |
| Backing measurements | 88 x 74 mm |
| Active surface | 36 cm² |
| Support | Polyethylene foam |
| Conductive adhesive | Hydrogel |
| Safety system | Without REM (does not activate the generator’s REM control) |
| Cable | Not included (tab connection) |
| Connection | TAB (tabs) |
| Use | Single-use (disposable, non-sterile) |
| Latex-free | Yes |
| Presentation | Box of 25 units with individual packaging |
| Regulatory classification | Medical device with CE marking |
Neonatal range of the foam family (88 x 74 mm): the references share the same foam backing and hydrogel adhesive; the difference is in the REM system and the mode of connection to the generator.
| Reference | Measurements | Active surface | REM | Cable | Connection |
| F7805N | 88 x 74 mm | 36 cm² | No | No | TAB (tabs) |
| F7820N | 88 x 74 mm | 36 cm² | Yes | No | TAB (tabs) |
| F7820NW/V | 88 x 74 mm | 36 cm² | Yes | 300 cm | Valleylab |
Equivalences and cross-references
There is no official equivalence table validated by the manufacturer that cross-references this reference with codes from other brands. The comparisons shown below are functional comparisons verified against public documentation from each cited manufacturer (GUDID/FDA regulatory databases and official catalogues) and should not be treated as 1:1 interchangeable without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Nissha Medical Technologies (Graphic Controls) | SWAROPLATE Non-Split Diathermy Pad Infant/Premature (no REM) | 1263H / 6001259N | Comparable by category (not interchangeable 1:1) | Very similar option: non-split return plate without REM control, polyethylene foam backing (PE foam) and conductive hydrogel adhesive, for infants and premature babies < 5 kg and single-use. They differ in measurements (165 x 74 mm vs 88 x 74 mm), conductive surface (35 cm² vs 36 cm²) and connection (Valleylab-NONREM plug with 3 m cable vs TAB without cable). Code and attributes verified in the manufacturer’s official catalogue. |
| Medtronic / Covidien (Valleylab) | Valleylab™ REM PolyHesive™ II Infant Patient Return Electrode | E7510-25 (UDI 10884524001043) | Comparable by category (not interchangeable 1:1) | Same single-use return function for infant patients from 2.7 to 13.6 kg. They differ in substrate (PolyHesive™ II hydrogel vs foam backing), safety system (split REM plate vs without REM), exact measurements and connection (integrated 2.7 m cable vs TAB without cable). Code and attributes verified in GUDID/FDA. |
The cited references have been cross-checked against regulatory databases (GUDID/FDA) and official catalogues of each cited manufacturer. Although they coincide in function (return without REM control, neonatal/infant low-weight population and single-use), they differ in substrate, exact measurements, active surface or connection system, so they are not 1:1 interchangeable. Other homologous families in the sector that should be evaluated with the technical data sheet in hand before any substitution: paediatric/neonatal neutral plates from B. Braun / Aesculap, PolyHesive series from Medtronic-Covidien / Valleylab, BOENMED infant grounding pads, Skintact from Leonhard Lang, disposable plates from GIMA, Promed and UpSpring Medical. In all cases, it must be checked field by field: exact dimensions, active surface in cm², backing and type of hydrogel, REM system, physical connector (TAB tabs) and compatibility with the installed electrosurgical generator. Do not assume equivalence based only on the generic product name.
There is no equivalence table validated by the manufacturer; consult with the technical department before using in a tender.
Selection tips and variants of interest
- Check your generator’s connection: the F7805N plate without cable with TAB connection needs a reusable plate cable (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for Erbe). Choose the cable according to the plug of your electrosurgical unit.
- Does your generator have REM control? The homologous alternative in the same size (88 x 74 mm) with REM system and TAB connection is the F7820N; if you prefer a plate with integrated 300 cm cable and Valleylab-type connection, choose the F7820NW/V.
- Other populations of the same family without REM: paediatric F7805P (148 x 90 mm, 78 cm², TAB) and adult F7805 (202 x 101 mm, 132 cm², TAB), as well as the cable versions F7805PW/V and F7805W/V.
- Extended compatibility: adapters F4828 (Valleylab-type connection to 4 mm plug) and F4829 (to 6.3 mm plug) for other generators.
- Application: always place on dry, intact, hair-free skin, on a well-vascularised muscle area and away from bony prominences. In neonatal patients, especially check the available contact surface and do not cut or reuse the plate. Check the integrity of the individual packaging and the expiry date before each use: it is a single-use and non-sterile product.