Description
Versatile neutral plate FIAB without cable with tab connection (Ref. F7320)
We present the versatile disposable neutral plate FIAB Ref. F7320, the single-use return electrode from the versatile range of the Italian manufacturer FIAB SpA (Vicchio, Florence). Designed to close the electrical circuit in monopolar electrosurgery in adults, it combines a conductive hydrogel adhesive on a foam backing with tab connection and no integrated cable, a configuration that reduces the cost per procedure and simplifies warehouse management. It is the usual choice in operating theatres, ambulatory major surgery units and minor surgery clinics that work with generators with REM control and reusable plate cable.
How this return plate with REM system works
In any procedure using a monopolar electrosurgical unit, the high-frequency current leaves through the active electrode (handle or pencil), passes through the patient’s tissue and must return to the generator via a low current density pathway: the neutral plate or dispersive electrode placed on the patient. If the skin-plate contact is poor or the return surface is insufficient, the current density at the return point increases and, with it, the risk of thermal burn.
This plate incorporates a REM system (Return Electrode Monitoring): the conductive surface is divided into two sectors, allowing the electrosurgical generator to continuously measure contact impedance. In the event of partial detachment, gel drying or any failure in contact quality, the equipment interrupts energy emission before injury occurs. The conductive hydrogel on a foam backing ensures anatomical adaptation, low contact impedance and uniform distribution of the return current. As it is supplied without a cable, it must be used with the appropriate reusable plate cable for your electrosurgical unit’s connector (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for Erbe), which connects to the plate’s tab.
Technical specifications
| Characteristic | Value |
|---|---|
| Product type | Versatile disposable neutral plate (return dispersive electrode) for monopolar electrosurgery |
| Brand / Manufacturer | FIAB / FIAB SpA (Vicchio, Florence, Italy) |
| Use | Disposable, single-use |
| Conductive gel | Hydrogel |
| Support | Foam |
| Cable | Not included (without cable) |
| Connection | Tab |
| Monitoring | REM (Return Electrode Monitoring) |
| Catalogue category FIAB | Electrosurgery > Neutral Electrodes > Disposable > Versatile |
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7320 |
| Packaging | Box of 100 individual units |
| Units per box (web) | 100 |
Equivalences and cross-references
Reference F7320 corresponds to the official catalogue of the manufacturer FIAB (versatile disposable neutral electrode with hydrogel, foam backing, without cable, tab connection and REM system) and Cahnos markets it without altering any characters. No reliable sources have been found for a manufacturer-validated equivalence table cross-referencing this code with codes from other brands; 1:1 substitutions should not be made without technical validation.
Within the same FIAB family, reference F7320W/V is the variant with integrated 300 cm cable, Valleylab-type connector and non-woven backing (TNT), presented in a box of 25 units. At category level, with technical data sheet in hand, homologous families in the sector can be evaluated, such as the PolyHesive cordless REM series from Medtronic/Covidien (Valleylab), the Skintact range from Leonhard Lang, SWAROPLATE plates from Nissha Medical Technologies and the split plates from B. Braun/Aesculap. Before any comparison in tenders, check field by field: gel type, backing, active surface, REM system, physical connector (TAB tab) and compatibility with the installed generator.
Selection tips and variants of interest
Check your generator’s connection: as this is a cableless plate with tab connection, it requires a reusable plate cable. Choose F7902 (universal, 6.3 mm mono jack), F7903 (Valleylab type with REM) or F7904 (6.3 mm jack for Erbe ACC/ICC/VIO/T) according to your electrosurgical unit’s plug; the cable is reused between patients and reduces the cost per procedure.
If you prefer a plate with integrated cable, reference F7320W/V from the same versatile range offers hydrogel on non-woven backing with 300 cm cable and Valleylab-type connector. For other configurations in the foam family with REM and tab connection, please refer to references F7820 (adult, 202 x 101 mm), F7820P (paediatric) and F7820N (neonatal); to extend compatibility with other generators, adapters F4828 and F4829 can be used.
Single-use product: do not reuse or re-sterilise. Always apply to dry, intact, hair-free skin, on a well-irrigated muscle area away from bony prominences, pacemakers and metal implants; check the integrity of the individual packaging before each use. For B2B volume conditions, hospital supply agreements or tenders, contact the technical-commercial team at Cahnos.





Reviews