Description
Disposable return plate with 3 m cable
The disposable electrosurgical plate (Ref. 30478) is the neutral return electrode that completes the monopolar circuit of your electrosurgical unit when operating on adult patients. It incorporates an integrated 3 m cable with Valleylab-type connection, making it directly usable with generators that use this plug standard, without the need for an additional cable. It is presented in a box of 25 units, each individually packed, the consumption format chosen by hospitals, clinics, ambulatory surgery centres and veterinary clinics that need a reliable supply with permanent stock for their surgical scheduling.
Why the return plate is important
In any monopolar electrosurgery procedure, the high-frequency current emitted by the active electrode (handle or pencil) passes through the patient’s tissue and must return to the generator via a low current density path. The neutral plate collects this current in a controlled manner: if the skin-plate contact is poor or the conductive surface is insufficient, the current density at the return point increases and, with it, the risk of thermal burn to the patient.
This single-use plate ensures uniform and stable contact on the skin of the adult patient. The integrated 3 m cable with Valleylab-type connection offers direct compatibility with the standard return socket of equipment with Valleylab plug and guarantees freedom of placement of the plate during the procedure. Being a plate with built-in cable, it is the ideal direct-use solution for the operating theatre and ambulatory surgery. Single-use product, non-reusable; check the integrity of the individual packaging and the expiry date before each use.
Technical specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 30478 |
| SKU Cahnos | GM30478 |
| Sales unit | Box of 25 units |
| Device type | Medical device |
| Device class | II B |
| CND | K02010202 |
| GMDN | 58494 |
| EAN | 8033003260203 |
Technical features
| Characteristic | Specification |
|---|---|
| Plate type | Disposable single-use return electrode (neutral plate) |
| Population | Adult |
| Cable | Integrated, 3 m |
| Connection | Valleylab type |
| Use | Single-use (disposable, non-reusable) |
| Packaging | Individual: all plates and cables are packed separately |
| Presentation | Box of 25 units |
Equivalences and cross-references
Reference 30478 (SKU Cahnos GM30478) is the manufacturer’s original catalogue designation for this disposable return plate with 3 m cable and Valleylab-type connection for adults. No 1:1 equivalence table validated by the manufacturer has been found in reliable sources that cross-references this reference with codes from other brands; any substitution must be validated field by field (electrode configuration, conductive surface, gel type and connector compatibility with the installed generator) with the technical department of Cahnos.
Within the catalogue itself, reference 30479 (SKU GM30479) corresponds to the disposable REM plate made of non-woven fabric with solid gel, 3 m cable and Valleylab-type connection for adults (same family of plates with integrated cable, with REM monitoring system). Ref. 30476 is another disposable plate with integrated cable for other generator configurations. As equivalent families in the sector that should be evaluated with the technical data sheet in hand, the return electrodes from Medtronic-Covidien (Valleylab PolyHesive series), Nissha Medical Technologies (SWAROPLATE), Aesculap (B. Braun) and Erbe are cited. Do not assume 1:1 interchangeability without prior technical validation.
Selection tips and variants of interest
Always check that the Valleylab-type plug of this plate is compatible with the connection of your electrosurgical generator. As it is a plate with integrated cable, it does not require an additional cable and is an ideal direct-use solution for operating theatres, major ambulatory surgery, minor surgery consultations and veterinary clinics. The box of 25 units with individual packaging facilitates stock management and traceability in surgical scheduling.
If your electrosurgical unit requires a split plate with contact control (REM system), consider reference 30479 (REM plate of non-woven fabric with solid gel, 3 m cable, Valleylab type, adult). If your generator has a clamp for plates with a tab and you prefer to reuse the cable between patients, consult the cableless versions of the same family (for example, Ref. 30495 with cable Ref. 30563) to optimise the cost per procedure.
Always apply the plate on dry, intact, hairless skin, in a well-irrigated muscular area and away from bony prominences, pacemakers or metallic implants; check the integrity of the individual packaging before each use. Disposable single-use product, non-reusable. For large orders you can request a quote: ask our technical-commercial team for B2B conditions and supply times.





Reviews
There are no reviews yet.