We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable foam electrosurgical plate for adults, 202 x 101 mm (132 cm²), without REM, with 300 cm cable and bipolar connection Ø6.3 mm — box of 25 units (Ref. F7805W6.3)

58,05 €

Disposable foam electrosurgical plate for adults, reference F7805W6.3, with an active surface of 132 cm² (202 x 101 mm), integrated 300 cm cable and bipolar jack connection of Ø6.3 mm. Without REM system, intended for electrosurgical units with a 6.3 mm bipolar socket. The hydrogel adhesive on a foam backing ensures anatomical adaptation, low impedance and uniform current distribution at the return point. Presentation in a box of 25 units with individual packaging, for operating theatre, ambulatory major surgery and sterilisation centre. Single-use, non-sterile product, with immediate supply for hospital consumption contracts.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7805W6.3

Description

Foam electrosurgical plate, bipolar connection Ø6.3 mm

The foam electrosurgical plate (neutral return electrode) is the essential consumable for completing the monopolar circuit of any high-frequency electrosurgery unit. This adult reference, with dimensions 202 x 101 mm and 132 cm² of active surface, incorporates an integrated 300 cm cable with bipolar jack connection of Ø6.3 mm, making it directly usable with generators that use this plug standard.

It is presented in a box of 25 units with individual packaging, the option chosen by hospitals, clinics and ambulatory surgery centres that need reliable, homogeneous consumption with permanent stock for their surgical scheduling.

How the return plate works and why it is important

In any procedure with a monopolar electrosurgical unit, the high-frequency current leaves through the active electrode (handle/pencil), passes through the patient’s tissue and must return to the generator via a low current density path. The neutral plate is responsible for collecting that current in a controlled manner: if the contact is not correct or the surface is insufficient, the current density at the return point increases and, with it, the risk of thermal burn.

This plate is constructed with a foam support and conductive hydrogel adhesive, which favours adaptation to the patient’s contour and uniform contact on the skin. The bipolar jack connection of Ø6.3 mm with 300 cm cable offers freedom of placement of the plate during the procedure. This reference belongs to the series without REM system: it does not activate the return monitoring control (REM) of the generator, so it must be used with conventional equipment without the requirement of a split plate, always selecting the lowest possible energy level.

Technical specifications

Characteristic Value
Reference / SKU F7805W6.3
Product type Disposable return plate (electrode) for monopolar electrosurgery
Measurements 202 x 101 mm
Active surface 132 cm²
Support Polyethylene foam
Conductive adhesive Hydrogel
Safety system Without REM (does not activate the generator’s REM control)
Cable length 300 cm
Connection Bipolar jack Ø 6.3 mm
Population Adult
Use Single-use (disposable, non-sterile)
Presentation Box of 25 units with individual packaging
Regulatory classification CE medical device

Adult range of the foam family without REM (same base of 132 cm²):

Reference Dimensions Support Active surface REM Cable Connection
F7805 202 x 101 mm Foam 132 cm² No No TAB (tab)
F7805W/V 202 x 101 mm Foam 132 cm² No 300 cm Valleylab
F7805W6.3 202 x 101 mm Foam 132 cm² No 300 cm Bipolar Ø 6.3 mm

The three references share the same hydrogel and foam base and the same active surface; the difference lies exclusively in the connection system to the generator.

Equivalences and cross-references

There is no official equivalence table validated by the manufacturer that cross-references this product with codes from other brands. The comparisons shown below are functional comparisons verified against public documentation from each cited manufacturer and should not be treated as 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
BOENMED ESU Plate with Cable, Bipolar, 6.3mm, Adult 512416 Comparable by category (not interchangeable 1:1) Disposable adult return plate with integrated cable and bipolar plug 6.3 mm, hydrogel adhesive. It differs in dimensions (not officially published), presentation (box of 500 units) and absence of active surface data in cm². Code and attributes verified in the manufacturer’s official catalogue.
BOENMED Diathermy Pad with Cable, Monopole, HIFI 6.3 Connector, Adult 512413 Comparable by category (not interchangeable 1:1) Same 6.3 mm plug and adult single-use with hydrogel adhesive. It differs in configuration (HIFI/monopolar type versus bipolar) and in presentation (box of 500 units). Code and attributes verified in the manufacturer’s official catalogue.
Erbe Elektromedizin NESSY Plate 170, split, with 3 m connection cable (for non-Erbe units, International) 20193-075 Comparable by category (not interchangeable 1:1) Disposable plate with integrated 3 m cable and active surface of 168 cm². It differs in the connector (specific NESSY/Erbe, not bipolar 6.3 mm plug), in the monitoring system (NESSY with split plate) and in the active surface. Code and attributes verified in Erbe’s official catalogue.

Equivalent brands and families that must be evaluated with their technical data sheet in hand before any substitution: AESCULAP (B. Braun) Patient Plates; Medtronic-Covidien / Valleylab PolyHesive corded series; Nissha Medical Technologies (Graphic Controls) Swaroplate; BOWA Medical return plates; EMED neutral electrodes; GIMA disposable plates for electrosurgical units; Taktvoll Patient Return Electrode. In all cases, it must be checked field by field: exact dimensions, active surface in cm², support and type of hydrogel, REM system, physical connector (6.3 mm plug) and compatibility with the installed electrosurgical generator. Do not assume equivalence based only on the generic product name.

There is no equivalence table validated by the manufacturer; consult with the technical department before using in tender.

Selection tips and variants of interest

Check the connector of your electrosurgical unit: this reference F7805W6.3 requires a bipolar jack socket of Ø6.3 mm and does not activate the REM control of the generator.

If your equipment uses a Valleylab-type connection, the equivalent option in the same plate body is the F7805W/V (202 x 101 mm, 132 cm², 300 cm cable).

If you prefer a cableless plate with tab connection (TAB), choose the F7805 and use a reusable adapter cable (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for ERBE), which reduces the cost per procedure.

For generators equipped with REM system, the alternative with return control in the same size and bipolar 6.3 mm connector is the F7820W/6.3 (202 x 101 mm, 118 cm², with REM). To expand compatibility, the adapters F4828 (from Valleylab-type connection to 4 mm plug) and F4829 (to 6.3 mm plug) can be used.

Paediatric and neonatal populations without REM: F7805P (148 x 90 mm, 78 cm², TAB), F7805PW/V (148 x 90 mm, 300 cm cable, Valleylab) and F7805N (88 x 74 mm, 36 cm², TAB).

Always apply to dry, intact, hair-free skin, on a well-vascularised muscle area away from pacemakers, metal implants or bony prominences; check the integrity of the individual packaging and the expiry date before use. Do not reuse or cut the plate.

Additional information

Product type

Disposable return plate (electrode) for monopolar electrosurgery

Measurements

202 x 101 mm

Active surface

132 cm²

Support

Polyethylene foam

Conductive adhesive

Hydrogel

REM system

Does not incorporate REM system

Cable length

300 cm

Connection

Bipolar jack Ø 6.3 mm

Use

Single-use (disposable, non-sterile)

Presentation

Box of 25 units with individual packaging

Regulatory classification

CE medical device

Tipo paciente

Adult

Reviews

There are no reviews yet.

Be the first to review “Disposable foam electrosurgical plate for adults, 202 x 101 mm (132 cm²), without REM, with 300 cm cable and bipolar connection Ø6.3 mm — box of 25 units (Ref. F7805W6.3)”

Your email address will not be published. Required fields are marked *