Adult foam electrosurgical plate 202 x 101 mm (132 cm²), without REM, with 300 cm cable and Valleylab-type connection — box of 25 units (Ref. F7805W/V)

50,31 €

Adult foam electrosurgical plate, reference F7805W/V, with an active surface area of 132 cm² (202 x 101 mm), integrated 300 cm cable and Valleylab-type connection. Without REM system: indicated for conventional electrosurgical units that do not require a split plate. The hydrogel adhesive on a polyethylene foam backing ensures anatomical adaptation, low contact impedance and uniform distribution of the return current. Presentation in box of 25 units with individual packaging; single-use and non-sterile product, with immediate supply for hospital consumption contracts and surgical scheduling.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7805W/V

Description

Foam electrosurgical plate with Valleylab-type connection

The foam electrosurgical plate (neutral return electrode) is the essential consumable for completing the monopolar circuit of any high-frequency electrosurgery equipment. This adult reference, measuring 202 x 101 mm with 132 cm² of active surface, incorporates an integrated 300 cm cable with Valleylab-type connection, making it directly usable with generators that use this plug standard. It is presented in a box of 25 units with individual packaging, the option chosen by hospitals, clinics and ambulatory surgery centres that need reliable, consistent consumption with permanent stock for their surgical scheduling.

How the return plate works and why it is important

In any procedure with a monopolar electrosurgical unit, the high-frequency current leaves through the active electrode (handpiece or pencil), passes through the patient’s tissue and must return to the generator via a low current-density path. The neutral plate is responsible for collecting that current in a controlled manner: if contact is not correct or the surface is insufficient, the current density at the return point increases and, with it, the risk of thermal burn to the patient.

This plate is constructed with a polyethylene foam backing and conductive hydrogel adhesive, which favours adaptation to the contour of the adult patient and uniform contact with the skin. The Valleylab-type connection with 300 cm cable offers freedom of plate placement during the procedure. This reference belongs to the without REM system series: it does not activate the generator’s return monitoring control (REM), so it must be used with conventional equipment without the requirement for a split plate, always selecting the lowest possible energy level.

Technical specifications

Characteristic Value
Reference / SKU F7805W/V
Product type Disposable return plate (electrode) for monopolar electrosurgery
Population Adult
Measurements 202 x 101 mm
Active surface 132 cm²
Support Polyethylene foam
Conductive adhesive Hydrogel
Safety system Without REM (does not activate the generator’s REM control)
Cable length 300 cm
Connection Valleylab type
Use Single-use (disposable, non-sterile)
Presentation Box of 25 units with individual packaging

Adult range of the foam family without REM (same 132 cm² base)

The three references share the same hydrogel and foam base and the same active surface; the difference lies exclusively in the connection system to the generator.

Reference Dimensions Support Active surface REM Cable Connection
F7805 202 x 101 mm Foam 132 cm² No No TAB (tab)
F7805W/V 202 x 101 mm Foam 132 cm² No 300 cm Valleylab type
F7805W6.3 202 x 101 mm Foam 132 cm² No 300 cm Bipolar Ø 6.3 mm

Equivalences and cross-references

There is no official equivalence table validated by the manufacturer cross-referencing the F7805W/V reference with codes from other brands. The comparisons shown below are functional comparisons verified against the official documentation of each cited manufacturer (catalogue, technical data sheet and GUDID/FDA regulatory databases) and should not be treated as 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Medtronic / Covidien (Valleylab) REM PolyHesive™ II Adult Patient Return Electrode (with cable) E7507 (UDI 10884524000077) Comparable by category (not interchangeable 1:1) Same return function for adult, single-use and Valleylab-type connector, indicated for patients over 13.6 kg. The substrate differs (PolyHesive™ II hydrogel adhesive versus polyethylene foam backing), the configuration (split REM plate versus non-REM plate) and the cable length (2.7 m versus 300 cm). Code and attributes verified in GUDID/FDA and on the manufacturer’s official website.
Nissha Medical Technologies (ex Graphic Controls) SWAROPLATE Split Diathermy Pad, Adult, REM connector 6000811N (ref. 1251H) Comparable by category (not interchangeable 1:1) Structurally very similar option: adult return plate with polyethylene foam backing (PE foam), conductive hydrogel adhesive and 3 m cable. The backing size differs (200 x 106 mm versus 202 x 101 mm), the adhesive surface (144 cm² versus 132 cm² active surface) and the configuration (split plate with REM control and Valleylab-REM connector versus non-REM plate). Code and attributes verified in the manufacturer’s official catalogue.
Leonhard Lang (Skintact® Cool Contact) Split neutral plate for adult, RS25 series RS25 / RS25A30 / RS25D30 Comparable by category (not interchangeable 1:1) Single-use adult plate with flexible foam backing, hydrogel adhesive and 3 m cable with 6.3 mm jack connector. The configuration differs (split with contact quality control, compatible with REM™, NESSY™ and aRM™ systems, versus non-REM plate) and the connector type (6.3 mm jack versus Valleylab type). Active surface of the base model RS25: 118 cm². Code and attributes verified in the manufacturer’s official technical documentation.

Brands and homologous families that must be evaluated with their technical data sheet in hand before any substitution: AESCULAP (B. Braun) Patient Plates; Medtronic-Covidien / Valleylab PolyHesive corded series; Nissha Medical Technologies (Graphic Controls) Swaroplate; BOWA Medical return plates; EMED neutral electrodes; GIMA disposable plates for electrosurgical units; Taktvoll Patient Return Electrode. In all cases, check field by field: exact dimensions, active surface in cm², backing and hydrogel type, REM system, physical connector and compatibility with the installed electrosurgical generator. Do not assume equivalence based solely on the generic product name.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.

Selection tips and variants of interest

Check the connector on your electrosurgical unit: this F7805W/V reference requires a Valleylab-type socket and does not activate the generator’s REM control. If your equipment uses a bipolar jack connection of Ø6.3 mm, the homologous option with the same plate body (202 x 101 mm, 132 cm², without REM) and 300 cm cable is the F7805W6.3.

If you prefer a cable-free plate with tab connection (TAB), choose the F7805 and use a reusable plate cable (F7902 universal 6.3 mm, F7903 Valleylab type or F7904 for Erbe), which lowers the cost per procedure. For generators fitted with a REM system, the alternative with return control in the same size and Valleylab-type connection is the F7820W/V (202 x 101 mm, 118 cm², with REM).

Paediatric and neonatal populations without REM: F7805P (148 x 90 mm, 78 cm², TAB), F7805PW/V (148 x 90 mm, 300 cm cable, Valleylab-type connection) and F7805N (88 x 74 mm, 36 cm², TAB). Always apply to dry, intact, hair-free skin, on a well-perfused muscular area away from pacemakers, metal implants or bony prominences; check the integrity of the individual packaging and the expiry date before each use. Do not reuse or cut the plate.

Additional information

Material

Polyethylene foam with conductive hydrogel adhesive

Measurements

202 x 101 mm

Active surface

132 cm²

Safety system

Without REM system (does not activate the generator's return monitoring control)

Connection

Valleylab type

Cable length

300 cm

Use

Single-use (disposable, non-sterile)

Presentation

Box of 25 units with individual packaging

Compatibility

Electrosurgical generators with Valleylab-type connector that do not require a REM plate

Regulatory classification

Medical device with CE marking, single-use, non-sterile

Tipo paciente

Adult