We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Cables for neutral electrode (patient plate) REGER — High-flexibility HF connection plugs for electrosurgical unit (Ref. 92176, 92078, 92077, 92039, 92076, 92344, 92345, 92139, 92108, 92145, 92109)

Price on request

Connection cables REGER Medizintechnik for the neutral electrode (patient plate) of the high-frequency surgery system, with a durable, very flexible and high-quality construction. They incorporate improved anti-corrosion protection through silver-plated copper wires and withstand a maximum voltage of up to 4.3 kVp, ensuring safe and stable evacuation of the return current. Available in lengths of 3 m and 5 m, with neutral electrode plug connector or flat plug for disposable neutral electrodes, in versions compatible with Berchtold, Martin, Erbe and Valleylab generators (including the Valleylab version with pin). Sold on quotation: consult our technical-commercial team.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-CABLE-NEUTRO

Description

Introduction

The neutral electrode (patient plate) cables from REGER Medizintechnik GmbH are the essential return accessories for completing the monopolar circuit of your high-frequency electrosurgical unit. Manufactured with a durable, very flexible and high-quality construction, they incorporate an improved anti-corrosion protection thanks to their silver-plated copper wires, which extends their service life and guarantees stable transmission of the return current intervention after intervention. Available in a wide range of references covering different connectors, lengths and generator manufacturers.

Technical explanation of the equipment

In monopolar electrosurgery, the high-frequency current emitted by the active electrode passes through the patient’s tissue and must return to the generator via the neutral electrode (patient plate). This cable establishes the connection between the plate and the generator’s return socket, forming the low current density path that protects the patient from thermal burns. The design of silver-plated copper wires reduces contact resistance and oxidation at the connector, while the high flexibility of the cable facilitates handling and placement in the operating theatre without generating stress on the plate. The cable’s ability to withstand a maximum voltage of up to 4.3 kVp ensures its correct operation in the most demanding high-frequency generators.

Technical specifications

The REGER range of neutral electrode cables offers versions with neutral electrode plug and with flat plug for disposable neutral electrodes, in lengths of 3 and 5 metres, adapted to the main generator manufacturers (Berchtold, Martin, Erbe and Valleylab). The manufacturer’s specifications and all available references are detailed below.

Manufacturer’s specifications

Characteristic Value
Construction Durable, very flexible and high quality
Anti-corrosion protection Improved by silver-plated copper wires
Maximum voltage (Umax) 4.3 kVp

Available references

REGER reference Length Connector Connection to the generator Reference Compatible with
92176 5 m Neutral electrode plug Berchtold; Martin 92176 Berchtold; Martin
92078 3 m Flat plug for disposable neutral electrodes Erbe; Martin 92078 Erbe; Martin
92077 3 m Neutral electrode plug Erbe; Martin 92077 Erbe; Martin
92039 5 m Flat plug for disposable neutral electrodes Erbe; Martin 92039 Erbe; Martin
92076 5 m Neutral electrode plug Erbe; Martin 92076 Erbe; Martin
92344 3 m Neutral electrode plug Erbe; Martin 92344 Erbe; Martin
92345 5 m Neutral electrode plug Erbe; Martin 92345 Erbe; Martin
92139 5 m Flat plug for disposable neutral electrodes Valleylab with pin 92139 Valleylab with pin
92108 3 m Neutral electrode plug Valleylab 92108 Valleylab
92145 5 m Flat plug for disposable neutral electrodes Valleylab 92145 Valleylab
92109 5 m Neutral electrode plug Valleylab 92109 Valleylab

Supplementary technical data

Characteristic Detail
Brand REGER Medizintechnik GmbH
Family HF surgery system > HF cables > Neutral electrode connectors
References (SKU) RGR-CABLE-NEUTRO, RGR-92176, RGR-92078, RGR-92077, RGR-92039, RGR-92076, RGR-92344, RGR-92345, RGR-92139, RGR-92108, RGR-92145, RGR-92109
Diameter (version 92078) 6.3 mm
Sale Under quotation

Equivalences and cross-references

This family of neutral electrode connection cables belongs to the standard of monopolar electrosurgery return accessories, so it is functionally related to the neutral plate cables of other electrosurgical unit manufacturers. Within the Cahnos catalogue itself, this range is complemented by reusable plate cables compatible with 4 mm sockets, Valleylab type or 6.3 mm jack (for example references F7922/F7922/4/F7922/24, F7923/F7923/F, F7902, F7903 and F7904). As homologous families in the sector that must be evaluated with their technical data sheet in hand before any replacement, the neutral electrode cables of Erbe, Valleylab, Berchtold and Martin are cited, as well as the cables for reusable plates from Aesculap (B. Braun), BOWA and GIMA. Do not assume 1:1 interchangeability without previously validating the connector, length and compatibility with your generator’s socket.

Selection tips and variants of interest

  • Choose according to your generator’s connection: references 92176, 92077, 92076, 92344, 92345, 92108 and 92109 have a neutral electrode plug; references 92078, 92039, 92139 and 92145 have a flat plug for disposable neutral electrodes.
  • Generator manufacturer: versions 92176 and 92139 are intended for Berchtold, Martin and Valleylab equipment with pin; the series for Erbe (92078, 92077, 92039, 92076, 92344 and 92345); and series 92108, 92109 and 92145 for Valleylab equipment.
  • Cable length: depending on the plate placement point and the cable route, choose between the 3 m versions (92078, 92077, 92344, 92108) and the 5 m versions (92176, 92039, 92076, 92345, 92139, 92145, 92109).
  • Check the plate you are going to use: flat plugs are for disposable neutral electrodes, while the neutral electrode plug is associated with reusable plates or those with a specific connector.
  • Verify the condition of the cable before each intervention (no cuts, kinks or deterioration of the insulation) and replace any cable that shows signs of damage.
  • For volume orders or B2B hospital supply conditions, consult the technical-commercial team of Cahnos.

Additional information

Longitud

5 m, 3 m

Conector

Clavija de electrodo neutro, Clavija plana para electrodos neutros desechables

Conexión al generador

Berchtold; Martin, Erbe; Martin, Valleylab con pin, Valleylab

Referencia

92176, 92078, 92077, 92039, 92076, 92344, 92345, 92139, 92108, 92145, 92109

Compatibility

Berchtold; Martin, Erbe; Martin, Valleylab with pin, Valleylab

Maximum voltage (Umax)

4.3 kVp

Product type

Connection cables for neutral electrode (patient plate)

Construction

Durable, very flexible and high quality

Anti-corrosion protection

Silver-plated copper wires

Maximum voltage

4.3 kVp

Available references

92176, 92078, 92077, 92039, 92076, 92344, 92345, 92139, 92108, 92145, 92109

Available lengths

3 m and 5 m

Connector types

Neutral electrode plug; flat plug for disposable neutral electrodes

Generator compatibility

Berchtold, Martin, Erbe, Valleylab (including Valleylab version with pin)

Diameter version 92078

6.3 mm

Reviews

There are no reviews yet.

Be the first to review “Cables for neutral electrode (patient plate) REGER — High-flexibility HF connection plugs for electrosurgical unit (Ref. 92176, 92078, 92077, 92039, 92076, 92344, 92345, 92139, 92108, 92145, 92109)”

Your email address will not be published. Required fields are marked *