Description
Introduction
The neutral electrode (patient plate) cables from REGER Medizintechnik GmbH are the essential return accessories for completing the monopolar circuit of your high-frequency electrosurgical unit. Manufactured with a durable, very flexible and high-quality construction, they incorporate an improved anti-corrosion protection thanks to their silver-plated copper wires, which extends their service life and guarantees stable transmission of the return current intervention after intervention. Available in a wide range of references covering different connectors, lengths and generator manufacturers.
Technical explanation of the equipment
In monopolar electrosurgery, the high-frequency current emitted by the active electrode passes through the patient’s tissue and must return to the generator via the neutral electrode (patient plate). This cable establishes the connection between the plate and the generator’s return socket, forming the low current density path that protects the patient from thermal burns. The design of silver-plated copper wires reduces contact resistance and oxidation at the connector, while the high flexibility of the cable facilitates handling and placement in the operating theatre without generating stress on the plate. The cable’s ability to withstand a maximum voltage of up to 4.3 kVp ensures its correct operation in the most demanding high-frequency generators.
Technical specifications
The REGER range of neutral electrode cables offers versions with neutral electrode plug and with flat plug for disposable neutral electrodes, in lengths of 3 and 5 metres, adapted to the main generator manufacturers (Berchtold, Martin, Erbe and Valleylab). The manufacturer’s specifications and all available references are detailed below.
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Construction | Durable, very flexible and high quality |
| Anti-corrosion protection | Improved by silver-plated copper wires |
| Maximum voltage (Umax) | 4.3 kVp |
Available references
| REGER reference | Length | Connector | Connection to the generator | Reference | Compatible with |
|---|---|---|---|---|---|
| 92176 | 5 m | Neutral electrode plug | Berchtold; Martin | 92176 | Berchtold; Martin |
| 92078 | 3 m | Flat plug for disposable neutral electrodes | Erbe; Martin | 92078 | Erbe; Martin |
| 92077 | 3 m | Neutral electrode plug | Erbe; Martin | 92077 | Erbe; Martin |
| 92039 | 5 m | Flat plug for disposable neutral electrodes | Erbe; Martin | 92039 | Erbe; Martin |
| 92076 | 5 m | Neutral electrode plug | Erbe; Martin | 92076 | Erbe; Martin |
| 92344 | 3 m | Neutral electrode plug | Erbe; Martin | 92344 | Erbe; Martin |
| 92345 | 5 m | Neutral electrode plug | Erbe; Martin | 92345 | Erbe; Martin |
| 92139 | 5 m | Flat plug for disposable neutral electrodes | Valleylab with pin | 92139 | Valleylab with pin |
| 92108 | 3 m | Neutral electrode plug | Valleylab | 92108 | Valleylab |
| 92145 | 5 m | Flat plug for disposable neutral electrodes | Valleylab | 92145 | Valleylab |
| 92109 | 5 m | Neutral electrode plug | Valleylab | 92109 | Valleylab |
Supplementary technical data
| Characteristic | Detail |
|---|---|
| Brand | REGER Medizintechnik GmbH |
| Family | HF surgery system > HF cables > Neutral electrode connectors |
| References (SKU) | RGR-CABLE-NEUTRO, RGR-92176, RGR-92078, RGR-92077, RGR-92039, RGR-92076, RGR-92344, RGR-92345, RGR-92139, RGR-92108, RGR-92145, RGR-92109 |
| Diameter (version 92078) | 6.3 mm |
| Sale | Under quotation |
Equivalences and cross-references
This family of neutral electrode connection cables belongs to the standard of monopolar electrosurgery return accessories, so it is functionally related to the neutral plate cables of other electrosurgical unit manufacturers. Within the Cahnos catalogue itself, this range is complemented by reusable plate cables compatible with 4 mm sockets, Valleylab type or 6.3 mm jack (for example references F7922/F7922/4/F7922/24, F7923/F7923/F, F7902, F7903 and F7904). As homologous families in the sector that must be evaluated with their technical data sheet in hand before any replacement, the neutral electrode cables of Erbe, Valleylab, Berchtold and Martin are cited, as well as the cables for reusable plates from Aesculap (B. Braun), BOWA and GIMA. Do not assume 1:1 interchangeability without previously validating the connector, length and compatibility with your generator’s socket.
Selection tips and variants of interest
- Choose according to your generator’s connection: references 92176, 92077, 92076, 92344, 92345, 92108 and 92109 have a neutral electrode plug; references 92078, 92039, 92139 and 92145 have a flat plug for disposable neutral electrodes.
- Generator manufacturer: versions 92176 and 92139 are intended for Berchtold, Martin and Valleylab equipment with pin; the series for Erbe (92078, 92077, 92039, 92076, 92344 and 92345); and series 92108, 92109 and 92145 for Valleylab equipment.
- Cable length: depending on the plate placement point and the cable route, choose between the 3 m versions (92078, 92077, 92344, 92108) and the 5 m versions (92176, 92039, 92076, 92345, 92139, 92145, 92109).
- Check the plate you are going to use: flat plugs are for disposable neutral electrodes, while the neutral electrode plug is associated with reusable plates or those with a specific connector.
- Verify the condition of the cable before each intervention (no cuts, kinks or deterioration of the insulation) and replace any cable that shows signs of damage.
- For volume orders or B2B hospital supply conditions, consult the technical-commercial team of Cahnos.






Reviews
There are no reviews yet.