Description
1. Commercial Introduction
We provide the electrosurgery wire electrode reference 30345 (SKU Cahnos: GM30345), a reusable consumable from the manufacturer’s electrosurgery range. Designed for use with autoclavable handles and electrode-holder pencils, its 1 mm wire tip angled at 45° and 10 cm in length enables precise cutting and coagulation in minor surgery, operating theatre, ambulatory surgery clinics and veterinary clinics. Withstanding up to 30 autoclave cycles, it offers a very competitive cost per procedure compared with disposable tips and reduces clinical waste in the surgical block.
2. Technical Explanation
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed through the neutral (dispersive) plate placed on the patient. Depending on the selected waveform, the effect is cutting, coagulation or blended.
The geometry of this electrode is designed to optimise access to the surgical field: the 1 mm diameter wire angled at 45° allows hard-to-see areas to be reached without straining the wrist, maintaining fine control of the tip during the manoeuvre. It is manufactured to be mounted on handles with a Ø 2.4 mm shaft housing, the standard of the autoclavable electrode family. As it is reusable, it must be cleaned and sterilised in an autoclave following the manufacturer’s instructions (up to 30 cycles), recording the number of sterilisations so that it can be withdrawn at any sign of deterioration.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 6 units |
| Device type | Medical device |
| Device class | II B |
| CND | Z12010980 |
| GMDN | 44683 |
| EAN | 8033638322161 |
Technical features
| Characteristic | Specification |
|---|---|
| Manufacturer reference | 30345 (SKU Cahnos: GM30345) |
| Internal reference number | 26 |
| Electrode type | Wire electrode (electrode wire) for monopolar electrosurgery |
| Wire diameter | 1 mm |
| Angulation | 45° |
| Length | 10 cm |
| Shaft compatibility | Handles with Ø 2.4 mm electrode housing (range) |
| Sterilisation | Autoclavable, up to 30 cycles |
| Instructions | Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, LT, PL, CZ, HU, HR, RO, GR and Arabic |
4. Equivalences and Cross-References
No official equivalence table validated by the manufacturer and cross-referencing reference 30345 with 1:1 codes from other brands has been found in reliable sources; any substitution with electrodes from another manufacturer must be validated field by field (wire diameter, angle, length, shaft diameter and authorised sterilisation cycles) with the technical department of Cahnos.
Yes, its functional relationship within the monopolar electrosurgery ecosystem with Ø 2.4 mm shaft has been verified:
| Manufacturer / Brand | Product / Family | Reference | Related items |
|---|---|---|---|
| (Italy) | Autoclavable ORION PLUS handle (pencil), dual push-button, screw fixation, 3 m silicone cable | 30539 (SKU GM30539) | Compatible handle (accepts Ø 2.4 mm shaft electrodes) |
| (Italy) | Sterile disposable straight blade electrode Ø 2.4 mm, 7 cm | 30671 | Shaft-compatible consumable, disposable alternative |
| (Italy) | Electrosurgery generators from the Diatermo series (e.g. refs. 30516, 30627–30635) | 30516, 30627, 30628, 30629, 30630, 30631, 30633… | Platform compatible with the handles and Ø 2.4 mm shaft electrodes in the range |
Consult the technical-commercial team of Cahnos before any substitution in a tender or use of equivalents from other manufacturers.
5. Selection tips and variants of interest
Always verify that the housing of your handle or electrosurgical pencil accepts Ø 2.4 mm shafts; it is the standard of the autoclavable electrode family, present on handles such as the ORION PLUS (ref. 30539) and in the standard equipment kits of the Diatermo generators.
Consider the tip geometry according to the technique: the wire angled at 45° improves ergonomics in lateral or inclined accesses, while straight tips or tips angled at other degrees are used according to the surgeon’s preference and the type of procedure. To replenish consumables from the same family, consider other Ø 2.4 mm shaft electrodes in the range (blade, needle or ball) and sterile disposable tips when single-use is prioritised.
Maintenance: after each procedure, clean the electrode according to the manufacturer’s instructions, sterilise it in an autoclave recording the number of cycles (maximum 30) and inspect it visually before each use, replacing it in the event of any deformation, corrosion or loss of fixation in the handle. For volume orders, hospital supply agreements or B2B terms, contact the technical-commercial team of Cahnos:. For large orders you can request a quote.







Reviews