Description
1. Product Presentation
We provide the sphere (ball) electrode for electrosurgery, reference 30339 (SKU Cahnos: GM30339), a reusable consumable from the manufacturer’s range of autoclavable electrodes. Its spherical tip of Ø 3 mm in straight geometry and 5 cm in length is designed to achieve reliable, reproducible and precise contact coagulation in every procedure, with less carbonisation and lateral thermal damage than needle or blade tips.
Being reusable and suitable for up to 30 autoclave sterilisation cycles, a single electrode maintains consistent performance over numerous procedures, significantly reducing the cost per procedure in hospitals, private clinics, minor surgery practices, ambulatory surgery and veterinary clinics. It is supplied in a box of 6 units, the ideal refill format for equipping the electrosurgery cart and keeping the operating theatre stock always available.
2. Technical explanation of the equipment and procedure
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil (electrosurgical unit) to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed through the neutral (dispersive) plate placed on the patient. Depending on the tip geometry, the predominant effect is cutting, coagulation or mixed.
The sphere (ball) tip of Ø 3 mm is indicated for contact coagulation, desiccation and controlled fulguration: its rounded shape distributes the current over a uniform surface, achieving effective haemostasis of small vessels and bleeding beds with minimal lateral thermal damage. It is the classic configuration for cauterising delicate surfaces, dermatological surgery, small haemorrhages and haemostasis touch-ups at the end of the procedure. In this straight 5 cm version it offers a contained reach and great control; if greater reach is required in deeper fields, the same family offers the 10 cm variant (ref. 30349).
The electrode is mounted on a Ø 2.4 mm shaft, the standard of the autoclavable electrode family, and is compatible with the handles and electrode-holding pencils with Ø 2.4 mm housing in the range. As it is reusable, it must be cleaned and sterilised in an autoclave following the manufacturer’s instructions (up to 30 cycles), recording the number of sterilisations to withdraw it at any sign of deterioration of the tip or the insulation.
3. Technical Specifications
Main features of the sphere electrode ref. 30339:
| Characteristic | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 30339 (SKU Cahnos: GM30339) |
| Internal reference number | 10 |
| Product type | Reusable monopolar electrosurgery electrode, sphere (ball) tip |
| Tip shape | Sphere (ball) |
| Ball diameter | Ø 3 mm |
| Geometry | Straight (0°) |
| Length | 5 cm |
| Shaft diameter | Ø 2.4 mm (autoclavable electrodes) |
| Sterilisation | Autoclavable, up to 30 cycles |
| Use | Reusable |
| Instructions | Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, LT, PL, CZ, HU, HR, RO, GR and Arabic |
| Sales unit | Box of 6 units |
| Device type | Medical device |
| Device class | II B |
| CND | Z12010980 |
| GMDN | 44683 |
Available references
| Reference | Length | Sales unit |
|---|---|---|
| GM30339 | POINT-STRAIGHT – 5 cm | box of 6 pcs |
| GM30349 | POINT – STRAIGHT – 10 cm | box of 6 pcs |
Product data
| Sales unit | box of 6 pcs |
|---|---|
| Device type | Medical device |
| Device class | II B |
| CND | Z12010980 |
| GMDN | 44683 |
4. Equivalences and Cross-References
Reference 30339 (SKU GM30339) is a code from the manufacturer’s official catalogue within its family of Ø 2.4 mm autoclavable electrodes. No equivalence table validated by the manufacturer has been found in public sources, regulatory databases (GUDID/FDA, EUDAMED) or official catalogues that cross-references this exact configuration (sphere Ø 3 mm + straight + 5 cm + Ø 2.4 mm shaft + reusable) with identical 1:1 codes from other brands. The following references are functional comparisons verified in the catalogue and should be treated as comparable at category level, not interchangeable 1:1 without validation by the technical department:
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Observations |
|---|---|---|---|---|
| (Italy) | Autoclavable sphere electrode Ø 3 mm straight, Ø 2.4 mm shaft | 30510 / 30530 | Comparable by category (not interchangeable 1:1) | Same spherical tip philosophy and Ø 2.4 mm shaft; the length and the declared number of autoclaving cycles differ. |
| Bovie / Aspen Surgical (USA) | Reusable ball electrode, 3/32″ shaft | A832M | Comparable by category (not interchangeable 1:1) | Reusable ball electrode with standard shaft (2.3–2.4 mm); sphere diameter, length and presentation differ. |
| Bovie / Aspen Surgical (USA) | Reusable 3 mm ball electrode with extended shaft | ES06R | Comparable by category (not interchangeable 1:1) | Shares category, material and Ø 3 mm spherical tip philosophy; total length and presentation differ. |
| ConMed (USA) | Hyfrecator, reusable ball electrode | 7-222-A | Comparable by category (not interchangeable 1:1) | Reusable ball electrode; shaft geometry and the connection system intended for the Hyfrecator family differ. |
There is no equivalence table validated by the manufacturer; consult the technical-commercial department of Cahnos before any substitution in tenders or standardisation of consumables. Before replacing an electrode from another brand, check field by field: sphere diameter (Ø 3 mm), geometry (straight), length (5 cm), shaft diameter (Ø 2.4 mm), sterilisation capacity (up to 30 cycles) and regulatory classification of the actual product.
5. Selection tips and variants of interest
Choose the tip geometry according to the desired effect and the tissue to be treated: the straight Ø 3 mm sphere in 5 cm (GM30339) is the high-control contact coagulation and haemostasis option, ideal for open surgery, minor surgery, dermatology and haemostasis touch-ups. If greater reach is needed for deeper surgical fields, the same family offers the 10 cm version (GM30349), also with a straight sphere tip and supplied in a box of 6 units.
Always check that the housing of your electrosurgical handle or pencil accepts Ø 2.4 mm shafts; this is the standard for the autoclavable electrode family, present in the electrode-holding handles and pencils in the range. To replenish consumables from the same family, consider other Ø 2.4 mm shaft electrodes (blade, needle or ball) and sterile disposable tips when single use is prioritised. Maintenance: after each procedure, clean the electrode according to the manufacturer’s instructions, sterilise it in an autoclave recording the number of cycles (maximum 30) and inspect it visually before each use, replacing it if there is any deformation, corrosion or loss of fixation in the handle. For volume orders, hospital supply agreements or B2B terms, contact the technical-commercial team at Cahnos:. For large orders you can request a quote.









Reviews