Description
1. Product Presentation
The reusable 15 x 8 mm loop electrode is an electrosurgery accessory designed for professionals seeking consistent performance with an optimised cost per procedure. Its 15 mm wide and 8 mm deep loop, mounted on a Ø 2.4 mm shaft, is particularly suitable for cutting and coagulation procedures in gynaecology, colposcopy and minor surgery. As an autoclavable product at 134 °C and non-sterile, it can be reprocessed in-house, making it a cost-effective alternative to single-use loop electrodes.
2. Technical explanation
In monopolar electrosurgery, the active electrode concentrates the high-frequency current generated by the electrosurgical unit at the point of contact with the tissue, which returns to the device via the neutral plate or dispersive electrode. The loop geometry delimits the contact area and allows controlled cutting and coagulation, obtaining tissue samples with defined margins and facilitating curved cuts on the cervical transformation zone.
The 15 x 8 mm (width x depth) profile offers an intermediate excision, ideal for the excision of small to medium-sized lesions in LEEP/LLETZ techniques (electrosurgical loop excision of the transformation zone) and for soft tissue surgery. Its Ø 2.4 mm and 13 cm long shaft provides ergonomic handling and adequate access during the procedure. As a reusable device, this electrode must undergo autoclave cycles at 134 °C following the manufacturer’s instructions.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Electrode shape | Loop |
| Electrode width | 15 mm |
| Electrode depth | 8 mm |
| Shaft diameter | Ø 2.4 mm |
| Stem length | 13 cm |
| Sterilisation | Autoclavable at 134 °C |
| Sterility | Non-sterile |
| Type of use | Reusable |
| Manufacturer reference | 30687 |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 unit |
| Device type | Medical device |
| Device class | II B |
| CND | K02030101 |
| EAN | 8023279306873 |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing reference 30687 with codes from other brands. This electrode is a reusable, autoclavable and non-sterile device, so it should not be considered 1:1 interchangeable with the disposable, sterile, single-use loop electrodes available on the market. As a functional category comparison, Cahnos also distributes disposable tungsten loop electrodes for LEEP/LLETZ (F46xx family), but they differ in sterility, presentation and life cycle; before any substitution, consult our technical department and check the manufacturer’s technical data sheet for the shaft diameter, exact geometry and sterilisation method.
5. Selection tips and variants of interest
First check the shaft diameter accepted by your electrosurgical pencil: the Ø 2.4 mm gauge of this model must fit correctly into the handle connector; if in doubt, consult the technical data sheet of your equipment. Next, select the loop geometry according to the technique: the 15 x 8 mm format offers a balance between width coverage and moderate depth, suitable for small and medium lesions with a curved contour; deeper loops allow larger samples, while square, trapezoidal or triangular loops are used depending on the contour and access. As a reusable electrode, inspect the loop after each autoclave cycle at 134 °C and remove it from service if any deformation occurs. For hospital purchases and tendering processes, always verify the CE marking and request special volume conditions from our commercial department.