Description
1. Commercial Introduction
The plastic surgery electrodes from REGER Medizintechnik GmbH (Germany) are high-precision active tips developed for use with high-frequency (HF) and radiofrequency (RF) electrosurgery systems in plastic, reconstructive and aesthetic surgery procedures. This line, with a Ø 2.4 mm shaft, groups a complete family of geometries – tungsten needle, tungsten wire loops and balls – to cover from fine electrosection to coagulation and precision haemostasis on soft tissue. They are reusable and autoclavable electrodes at 134 °C, a cost-effective and reliable solution for operating theatres, aesthetic surgery clinics and ambulatory surgery centres. They are sold on quotation; request your quote from our technical-commercial team.
2. Technical explanation
In a monopolar electrosurgery system, the electrosurgical generator (HF or RF) applies high-frequency current to the tissue through the active electrode, which concentrates the current density at the tip to cut, coagulate or combine both effects; the circuit is closed via the neutral or dispersive plate placed on the patient. The geometry of the tip determines the clinical behaviour: the tungsten needle (Ref. 390-0) concentrates energy at a minimal point for guided incisions and pinpoint haemostasis; the tungsten wire loops, in triangular, rhombus and round versions, allow resections and shaping with very reduced lateral thermal damage; and the balls (Ref. 381-0 and 383-0) offer uniform contact coagulation. All electrodes incorporate anti-rotation hexagonal protection, which prevents rotation of the tip inside the handpiece during use, and withstand a maximum voltage (Umax) of 4.3 kVp. Being reusable, they allow sterilisation in an autoclave at 134 °C, ensuring consistent performance cycle after cycle.
3. Technical Specifications
Data verified against the official catalogue of REGER Medizintechnik GmbH (HF surgery system > HF electrodes > plastic surgery) and the Cahnos-Catalog-Loader load. The manufacturer’s specification tables are preserved in full.
General characteristics
- Applicable to high-frequency (HF) and radiofrequency (RF) generators
- Reusable
- Autoclavable (134 °C)
- With hexagonal anti-rotation protection
- Shaft of Ø 2.4 mm
- Pack of 5 units per reference
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Maximum voltage (Umax) | 4.3 kVp |
Product data
| Field | Detail |
|---|---|
| Brand | REGER |
| Manufacturer | REGER Medizintechnik GmbH (Germany) |
| SKU Cahnos | RGR-HF-PLASTICA-24 |
| Product type | Active electrodes for plastic surgery (needle, wire loops and balls) |
| Shaft diameter | Ø 2.4 mm |
| Compatibility | High-frequency (HF) and radiofrequency (RF) generators |
| Type of use | Reusable |
| Sterilisation | Autoclave (134 °C) |
| Fixation system | Hexagonal anti-twist protection |
| Units per pack | 5 |
| Sale | Under quotation |
Available references
| REGER reference | Model | Size | Units per pack |
|---|---|---|---|
| 390-0 | Needle | Dimensions 20 mm, Ø 0.3 mm · Material tungsten | 5 |
| 384-0 | Wire loop, triangular | Dimensions 7 mm, Ø 0.2 mm · Material tungsten | 5 |
| 384-1 | Wire loop, triangular | Dimensions 9 mm, Ø 0.2 mm · Material tungsten | 5 |
| 384-2 | Wire loop, rhombus | Dimensions 10 mm x 6 mm · Material tungsten | 5 |
| 384-3 | Wire loop | Diameter Ø 5 mm · Wire thickness Ø 0.2 mm | 5 |
| 384-4 | Wire loop | Diameter Ø 8 mm · Wire thickness Ø 0.2 mm | 5 |
| 381-0 | Ball | Diameter Ø 1 mm | 5 |
| 383-0 | Ball | Diameter Ø 3 mm | 5 |
4. Equivalences and Cross-References
The references 390-0, 384-0 to 384-4, 381-0 and 383-0 are the original designations from the REGER Medizintechnik GmbH catalogue for plastic surgery electrodes with a Ø 2.4 mm shaft. In the Cahnos catalogue they are identified under the SKUs RGR-390-0, RGR-384-0, RGR-384-1, RGR-384-2, RGR-384-3, RGR-384-4, RGR-381-0 and RGR-383-0, within the RGR-HF-PLASTICA-24 family (double coding of the same product). No reliable source has been found for a 1:1 equivalence table validated by the manufacturer that cross-references these exact configurations (geometry, dimensions and Ø 2.4 mm shaft) with codes from other brands. Needle, wire loop and ball electrodes from other manufacturers are comparable only at category level and are not interchangeable without field-by-field verification: tip geometry and dimensions, shaft diameter, fixation system (anti-rotation hexagonal) and electrical compatibility with the generator. Consult our technical-commercial department before using any equivalence in tenders or substitutions.
5. Selection tips and variants of interest
Choose reference 390-0 (tungsten needle, 20 mm x Ø 0.3 mm) for fine incisions, pinpoint haemostasis and maximum precision work in delicate areas. Tungsten wire loops are selected according to the required resection: triangular 7 mm (384-0) or 9 mm (384-1) for medium shaping, rhombus 10 mm x 6 mm (384-2) for larger areas, and round Ø 5 mm (384-3) or Ø 8 mm (384-4) for circular and contour resections. For contact coagulation, choose the Ø 1 mm ball (381-0) for pinpoint haemostasis of small vessels and the Ø 3 mm (383-0) for larger surfaces. Always verify that your electrode holder handpiece accepts the Ø 2.4 mm shaft and the hexagonal fixation system before purchase. As they are reusable, reprocess the electrodes in an autoclave at 134 °C following the manufacturer’s instructions and check the condition of the tip and wire after each cycle. Within the REGER plastic surgery range, Cahnos also offers the family with a Ø 4 mm shaft (Ref. 282-0, 290-0 and 284-0 to 284-4) and the Ø 1 mm and Ø 3 mm balls from the RGR-HF-PLASTICA-BOLA family (Ref. 281-0 and 283-0), as well as the wire loop with a Ø 1.6 mm shaft (Ref. 482-0). For institutional volumes, hospital supply agreements or annual consumption terms, contact the technical-commercial team at Cahnos.