Description
1. Product Presentation
The disposable monopolar electrosurgery electrode with a Ø 4 mm ball tip and 70 mm length, reference 30672, is the reference coagulation consumable for achieving effective, clean and safe contact haemostasis during the procedure. Its rounded sphere concentrates the high-frequency current over a large, uniform surface, ideal for coagulating and sealing soft tissue and small vessels with controlled energy delivery and reduced carbonisation of adjacent tissue.
Each box contains 24 sterile single-use units, with individual heat-sealed packaging that maintains sterility until opened in the operating theatre: the most hygienic and cost-effective solution for hospitals, private clinics, ambulatory major surgery centres and minor surgery clinics, eliminating the risk of cross-contamination and the costs of cleaning and re-sterilisation.
2. Technical explanation and operation
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil (electrosurgical unit) to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed through the neutral (dispersive) pad placed on the patient. Depending on the selected waveform, the tip geometry determines the predominant effect of cut, coagulation or blend.
The Ø 4 mm ball tip is designed for contact coagulation, desiccation and controlled fulguration: its rounded shape distributes the current over a larger surface, achieving effective haemostasis of small vessels and bleeding beds with reduced lateral thermal damage compared to other tip geometries. It is the classic configuration for cauterisation of delicate surfaces, dermatological surgery, minor haemorrhages and haemostasis touch-ups at the end of the procedure. The 70 mm length offers a contained reach with great control, ideal for open surgery, minor surgery, dermatology and medium-depth approaches, and its 2.38 mm (3/32″) universal connection shaft is compatible with practically all pencils and electrosurgical units on the market without the need for adapters.
3. Technical Specifications
| Reference | Ref. 30672 (SKU GM30672) |
|---|---|
| Product type | Disposable monopolar electrosurgery electrode, ball tip |
| Tip shape | Sphere (ball) |
| Ball diameter | 4 mm |
| Length | 7 cm (70 mm) |
| Use | Disposable, single-use |
| Sterility | Sterile, individual packaging |
| Compatibility | Pencils and electrosurgical units with universal 2.38 mm (3/32″) shaft housing, type Valleylab, ConMed, Bovie, Erbe and compatible |
| Manufacturer | GIMA |
| Sales unit | Box of 24 units |
| Device type | Medical device |
| Device class | II B |
| CND | K0201010301 |
| GMDN | 61874 |
| EAN | 8033003260043 |
Available references: Ref. 30672 · SKU GM30672 · EAN 8033003260043.
4. Equivalences and Cross-References
Reference 30672 is a code from the manufacturer’s official catalogue. A validated equivalence table from the manufacturer cross-referencing this exact configuration (Ø 4 mm ball + 70 mm + sterile disposable) with identical 1:1 codes from other brands has not been found in public sources. The following references are functional comparisons within the same category, verified against official catalogues and regulatory databases of the sector, and should not be treated as 1:1 interchangeable without validation from the technical department:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level |
|---|---|---|---|
| (Italy) | Autoclavable ball electrode for monopolar handpieces of the range | 30510 / 30530 | Comparable by category (reusable, not 1:1 interchangeable) |
| Bovie / Aspen Surgical (USA) | Disposable Ball Electrode (stainless steel sphere, single-use, sterile) | ES21 (ball 5/32″ ≈ 3.97 mm, shaft 3/32″) | Comparable by category (not interchangeable 1:1) |
| KLS Martin (Germany) | smartOne® ball electrode (Ø 4 mm ball, sterile, single-use) | 80-700-08-04 (Ø 4 mm × 70 mm) | Comparable by category (not interchangeable 1:1) |
| Medtronic / Valleylab | Valleylab™ Ball Electrode (single-use, sterile) | E1563 (Ø 3 mm) / E1564 (Ø 5 mm) | Comparable by category (not interchangeable 1:1) |
Before any substitution, check field by field: ball diameter (4 mm exact), total length (70 mm), shaft diameter (2.38 mm / 3/32″), sterility, single-use and presentation.
5. Selection tips and variants of interest
The choice of tip geometry must be based on the surgical technique and the tissue to be treated. The Ø 4 mm ball with 70 mm length is indicated for contact coagulation and haemostasis of large surfaces and soft tissue in medium-depth approaches, such as open surgery, dermatological surgery, minor surgery and biopsies, with great control thanks to its contained length.
If you need more reach for deep surgical fields, consider a longer ball tip (e.g. 150–156 mm within the same disposable electrode family), and if you prefer a larger coagulation surface, the Ø 5 mm ball is a common alternative. In applications where avoiding eschar adherence is a priority, there are titanium or Teflon/PTFE coated versions of the same ball geometry. Always check that your pencil accepts a 2.38 mm (3/32″) shaft, the universal standard compatible with Valleylab, ConMed, Bovie, Erbe and compatible units. This is a single-use product: do not re-sterilise or reuse. For institutional volumes, supply agreements or tenders, consult our technical-commercial department.





Reviews