Disposable tungsten electrosurgery electrode, square loop 10 × 4 mm, sterile Ø 2.38 mm (3/32″) shaft — Box of 24 units (Ref. F4630)

119,71 €

Disposable electrosurgery electrode with a square tungsten wire loop of 10 × 4 mm and a universal stainless steel shaft Ø 2.38 mm (3/32″), compatible with most electrosurgical pencils on the market. Sterile single-use consumable (ethylene oxide), latex-free, indicated for cutting and coagulation, cervical excision LEEP/LLETZ and soft tissue surgery. Presentation in a box of 24 individually packaged units. Reference F4630, available for immediate order.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
F4630

Description

1. Product Presentation

The disposable electrosurgery electrode Ref. F4630 is a single-use consumable with a tip in the form of a square loop of 10 × 4 mm, made of tungsten wire and mounted on a stainless steel shaft of Ø 2.38 mm. It is supplied in a box of 24 individually packaged units, a format designed to ensure stock rotation and consumption planning in operating theatres, gynaecology units, colposcopy clinics and minor surgery rooms. It is the ideal reference for professionals seeking a reliable, sterile replacement electrode with an optimised cost per procedure.

2. Technical explanation

In monopolar electrosurgery, the active electrode concentrates the high-frequency current emitted by the electrosurgical generator; the energy is applied at the point of contact with the tissue and returns through the neutral plate. The geometry of the loop delimits the contact area and allows controlled cutting and coagulation, extracting a tissue sample with defined margins.

The tungsten wire offers two clinical advantages over steel: it maintains the shape of the loop throughout the procedure even at high powers and minimises carbonisation and lateral thermal damage, favouring the histological quality of the sample. The square profile of 10 × 4 mm (width 10 mm, depth 4 mm) provides a narrow and shallow excision, ideal for small lesions with regular contours in the cervical transformation zone. The Ø 2.38 mm shaft corresponds to the compatibility standard of most electrosurgical pencils and handles on the market (equivalent to 3/32″). Being a single-use product, the risk of cross-contamination and reprocessing costs are eliminated.

3. Technical Specifications

Characteristic Value
Tip shape Square loop (square loop)
Loop dimensions 10 × 4 mm
Loop material Tungsten
Shaft material AISI stainless steel
Shaft diameter 2.38 mm (3/32″)
Type of use Disposable, single-use
Sterility Sterile, individually packaged (ethylene oxide)
Latex Latex-free
Presentation Box of 24 units
Application Cutting and coagulation; cervical excision (LEEP/LLETZ, conisation) and soft tissue surgery
Compatibility Electrosurgical pencils and generators with shaft Ø 2.38 mm (3/32″)
Reference F4630

4. Equivalences and Cross-References

Reference F4630 is a distribution code proprietary to Cahnos; there is no equivalence table validated by the manufacturer that cross-references this code with codes from other brands. The following references are offered as a functional comparison of category verified against the cited sources (official manufacturer or authorised distributor catalogue, and the GUDID regulatory database), never as direct 1:1 interchangeable products:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Gynex Corporation LLETZ-Square Loop Electrodes, Single-Use 19-1004 Comparable by category (not interchangeable 1:1) Square loop 10 × 4 mm in tungsten wire (0.20 mm), handle with HexLoc anti-rotation system, standard 3/32″ connector, sterile and single-use; box of 5 units. Verified in the official manufacturer’s catalogue. Differs in presentation (5 units) and handle design.
MedGyn Products Disposable Square Loop Electrode 028072 Comparable by category (not interchangeable 1:1) Square loop 10 × 4 mm in tungsten wire on a stainless steel shaft of 2.3 mm, sterile and disposable; pack of 5 units. Verified in the official manufacturer’s catalogue. Differs in packaging (5 units) and shaft diameter (2.3 mm).
AB Medica Group – LESSA Sterile disposable TUNGSTEN LOOP electrode (rectangular) 88.200.76 Comparable by category (not interchangeable 1:1) Rectangular (square) loop 10 × 4 mm, total length 135 mm, sterile, 24 units individually packaged; distribution alternative in Spain. Verified in the official LESSA distributor catalogue. Identical presentation in units per box.
CooperSurgical (LEEP®) LEEP Square Condyloma Electrode S1004 Comparable by category (not interchangeable 1:1) Square loop of 1.0 × 0.4 cm (10 × 4 mm) in tungsten wire with a 5.5 cm shaft and 15° curvature, sterile and single-use. Verified in GUDID (DI 00888937010862). Differs by the shaft curvature and its specific indication (condylomas).

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Before substituting with another brand, compare shaft diameter, exact tip geometry (square, round or triangular), sterility and units per pack with the manufacturer’s datasheet.

5. Selection tips and variants of interest

To choose the replacement electrode correctly, first verify the shaft diameter accepted by your electrosurgical pencil (the Ø 2.38 mm standard is the most widespread; versions of Ø 4 mm exist). Next, select the loop geometry according to the technique: the square profile of 10 × 4 mm offers a narrow and shallow excision, ideal for small lesions with regular margins; round loops facilitate curved cuts and trapezoidal or triangular ones are used for more restricted access or wider excisions.

In this same family, interesting variants are offered in boxes of 24 units: F4631 (square loop 10 × 8 mm), F4632 (square loop 10 × 10 mm), F4623 (round loop 10 × 10 mm), F4640 (trapezoidal 30 × 5 mm), F4641 (inverted curved 23 × 13 mm) and F4642 (triangular 17 × 12 mm). For hospital purchases and tender processes, always check the CE marking under Regulation (EU) 2017/745 (MDR) and request special volume conditions from our commercial department.

Additional information

Loop shape

Square loop (square loop)

Loop material

Tungsten

Shaft material

AISI stainless steel

Shaft diameter

2.38 mm (3/32 inch)

Usage type

Disposable, single-use

Sterility

Sterile, individually packaged (ethylene oxide)

Presentation

Box of 24 units

Compatibility

Electrosurgical pencils and generators with shaft Ø 2.38 mm (3/32")

Application

Cutting and coagulation; cervical excision (LEEP/LLETZ, conisation) and soft tissue surgery

Reference

F4630

Shape

Square loop (square loop)

Loop dimensions

10 × 4 mm

Sterilisation

Ethylene oxide (EO), individual sterile packaging

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Disposable tungsten electrosurgery electrode, square loop 10 × 4 mm, sterile Ø 2.38 mm (3/32″) shaft — Box of 24 units (Ref. F4630)”

Your email address will not be published. Required fields are marked *