We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable tungsten electrosurgery electrode, square loop 10 × 10 mm, Ø 2.38 mm shaft – Box of 24 units (Ref. F4632)

119,71 €

Disposable electrosurgery electrode with square tungsten loop of 10 × 10 mm, reference F4632, in a box of 24 units. Single-use consumable for cutting and coagulation procedures with high-frequency current, indicated for LEEP/LLETZ-type cervical excision techniques and conisation, as well as for open surgery on soft tissue. Tungsten wire preserves the loop geometry throughout the procedure and reduces carbonisation; the Ø 2.38 mm shaft is compatible with most standard electrosurgical pencils. Sterile and disposable format for maximum safety and traceability in the operating theatre. Price per box of 24 units.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
F4632

Description

1. Product Presentation

The disposable electrosurgery electrode F4632 is a single-use consumable with a tip in the form of a square loop of 10 × 10 mm, made of tungsten wire and mounted on a Ø 2.38 mm shaft. It is marketed in a box of 24 units, a format designed to ensure stock rotation and consumption planning in operating theatres, gynaecology units and minor surgery clinics. It is the ideal reference for professionals seeking a reliable, sterile replacement electrode with an optimised cost per procedure.

2. Technical explanation

In monopolar electrosurgery, the active electrode concentrates the high-frequency current emitted by the electrosurgical generator; the energy is applied at the point of contact with the tissue and returns through the neutral plate. The loop geometry delimits the contact area and allows controlled cutting and coagulation, extracting a tissue sample with defined margins. Tungsten wire offers two clinical advantages over steel: it maintains the shape of the loop throughout the procedure even at high powers and minimises carbonisation and lateral thermal damage, which favours the histological quality of the sample. The Ø 2.38 mm shaft corresponds to the compatibility standard of most electrosurgical pencils and handles on the market (including the 3/32″ standard). Being a single-use product, the risk of cross-contamination and reprocessing costs are eliminated.

3. Technical Specifications

Characteristic Value
Shape Square loop (square loop)
Loop dimensions 10 × 10 mm
Wire material Tungsten
Shaft diameter 2.38 mm
Type Disposable (single-use)
Sterility Sterile, single-use packaging
Presentation Box of 24 units
Application Cutting and coagulation; cervical excision (LEEP/LLETZ, conisation) and soft tissue surgery
Compatibility Electrosurgical pencils and generators with Ø 2.38 mm shaft
Reference F4632

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer that cross-references F4632 with codes from other brands. The following references are offered as a functional category comparison verified against the cited sources (official manufacturer catalogue, GUDID regulatory database or official distribution catalogue), never as direct 1:1 interchangeable items:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
CooperSurgical (LEEP®) LEEP Square Electrodes S1010 Comparable by category (not interchangeable 1:1) Square tungsten wire loop 10 × 10 mm, universal 3/32″ (≈2.4 mm) shaft, 12 cm, sterile, single-use; box of 5 units. Verified in GUDID (DI 00888937010886) and in the official manufacturer catalogue.
Megadyne (Ethicon / Johnson & Johnson group) Megadyne™ LLETZ Loops 0450 Comparable by category (not interchangeable 1:1) LLETZ loop 10 × 10 mm in tungsten wire with stable “Y” construction, 11.8 cm shaft, sterile and disposable; box of 12 units. Tip with yellow colour code. Verified in the official Ethicon code directory.
Bioteque LEEP/LLETZ Square Loop Electrode OB1010S Comparable by category (not interchangeable 1:1) Square loop 10 × 10 mm in tungsten wire, sterile and disposable; box of 5 units. Code consistent across several independent distribution catalogues (e.g. McKesson 852013); pending confirmation in official regulatory databases.
AB Medica Group – LESSA Sterile disposable TUNGSTEN LOOP electrode (rectangular) 88.200.78 Comparable by category (not interchangeable 1:1) Rectangular (square) loop 10 × 10 mm, total length 141 mm, sterile, 24 units individually packaged; distribution alternative in Spain. Verified in the official LESSA distributor catalogue.

The homologous brands and families on the market for this category (disposable tungsten loops for cervical excision) include, in addition to those mentioned, the LLETZ ranges from Medtronic and Medline, as well as loop electrodes from Erbe, MedGyn and Promed available in the main electrosurgery catalogues. Before using any of these references in tenders or stock replacement, consult the technical department and check shaft diameter, exact tip geometry (square, round or triangular), sterility and units per pack against the manufacturer’s data sheet.

5. Selection tips and variants of interest

To choose the replacement electrode correctly, first check the shaft diameter accepted by your electrosurgical pencil (the Ø 2.38 mm standard is the most widespread; there are versions of Ø 4 mm and 3/32″). Next, select the loop geometry according to the technique: the square 10 × 10 mm loop offers a wide, homogeneous excision profile, ideal for conisation and for samples with regular margins; round loops facilitate curved cuts and trapezoidal or triangular ones are used in more restricted access. In this same family, interesting variants are offered: F4623 (round loop 10 × 10 mm), F4631 (square loop 10 × 8 mm) and F4630 (square loop 10 × 4 mm), all in boxes of 24 units. For hospital purchases and tender processes, always check the CE marking under Regulation (EU) 2017/745 (MDR) and request special volume conditions from our commercial department.

Additional information

Shape

Square loop (square loop)

Loop dimensions

10 × 10 mm

Tip material

Tungsten wire

Shaft diameter

2.38 mm

Product type

Disposable, single-use

Presentation

Box of 24 units

Application

Cutting and coagulation; cervical excision (LEEP/LLETZ, conisation)

Compatibility

Electrosurgical pencils and generators with Ø 2.38 mm shaft

Reference

F4632

Esterilidad

Sterile

Reviews

There are no reviews yet.

Be the first to review “Disposable tungsten electrosurgery electrode, square loop 10 × 10 mm, Ø 2.38 mm shaft – Box of 24 units (Ref. F4632)”