Autoclavable monopolar electrosurgery electrode with straight loop (lasso) tip · Ø 2.4 mm · Ref. GM30336/GM30346 · Box of 6 units

Price range: 58,90 € through 67,45 €

Electrosurgery electrode reusable and autoclavable up to 30 cycles from the range, with a straight loop (lasso) tip on a Ø 2.4 mm shaft. Indicated for fine cutting, dissection and localised coagulation with monopolar electrosurgery equipment; it mounts on the handles and electrode-holding pencils with Ø 2.4 mm housing from the same family. Supplied in a box of 6 units, in 5 cm (GM30336) and 10 cm (GM30346) versions. Class II B medical device. For large orders you can request a quote.

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30336-F

Description

1. Product Presentation

We offer the straight loop (lasso) electrode for electrosurgery (references 30336 and 30346, SKU Cahnos GM30336 and GM30346), a reusable consumable from the manufacturer’s range of autoclavable electrodes with Ø 2.4 mm shaft. Its straight loop tip is designed to achieve fine cutting, controlled dissection and reliable localised coagulation in every open surgery, minor surgery and outpatient procedure.

Being reusable and supporting up to 30 autoclave sterilisation cycles, a single electrode maintains consistent performance over numerous procedures, reducing the cost per intervention compared with disposable tips. It is supplied in a box of 6 units, the ideal format for equipping the electrosurgery cart and keeping the operating theatre stock always available.

2. Technical explanation of the equipment and procedure

In a monopolar electrosurgery system, the electrosurgical generator sends high-frequency current through the pencil (electrosurgical unit) to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed via the neutral (dispersive) plate placed on the patient. Depending on the tip geometry, the predominant effect is cutting, coagulation or mixed.

The loop or lasso tip concentrates the electrosurgical effect on a small, defined surface, making it especially useful for controlled cutting, tissue excision and pinpoint haemostasis with minimal lateral thermal damage. This straight loop version offers direct handling and high precision; if greater reach is needed in deep fields, the same family offers the 10 cm variant (ref. 30346). The electrode is mounted on a Ø 2.4 mm shaft, the standard of the autoclavable electrode family, and is compatible with the handles and electrode-holding pencils with Ø 2.4 mm housing in the range.

3. Technical Specifications

Characteristic Specification
Manufacturer GIMA
Manufacturer references 30336 (5 cm) · 30346 (10 cm)
SKU Cahnos GM30336 · GM30346
Internal reference number 7
Product type Reusable monopolar electrosurgery electrode, loop (lasso) tip
Tip shape Straight loop (lasso) – straight slip-knot
Length 5 cm (GM30336) · 10 cm (GM30346)
Shaft diameter Ø 2.4 mm (autoclavable electrodes)
Sterilisation Autoclavable, up to 30 cycles
Use Reusable
Instructions Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, LT, PL, CZ, HU, HR, RO, GR and Arabic
Sales unit Box of 6 units

Available references

Reference Length Sales unit
GM30336 5 cm Box of 6 units
GM30346 10 cm Box of 6 units

Product data

Sales unit Box of 6 units
Device type Medical device
Device class II B
CND Z12010980
GMDN 44683

4. Equivalences and Cross-References

Reference 30336 (SKU GM30336) is a code from the manufacturer’s official catalogue within its family of autoclavable electrodes with Ø 2.4 mm shaft. Its direct equivalent in the same catalogue is the 10 cm version GM30346, which shares the same straight loop tip geometry. The angled loop variant is GM30337/GM30347, and the rest of the Ø 2.4 mm autoclavable electrode family (wires, hooks and balls) is interchangeable in terms of attachment to the handle.

No equivalence table validated by the manufacturer that cross-references this exact configuration (straight loop + Ø 2.4 mm shaft + reusable) with identical 1:1 codes from other brands has been found in public sources or regulatory databases. Before replacing an electrode from another brand, the technical-commercial department of Cahnos recommends validating field by field: tip geometry, length, shaft diameter, sterilisation capacity and regulatory classification of the actual product.

5. Selection tips and variants of interest

Choose the length according to the surgical field: the 5 cm version (GM30336) is the most manageable for small fields and minor surgery, while the 10 cm version (GM30346) provides greater reach in deep accesses. Both are supplied in a box of 6 units.

Always verify that the housing of your electrosurgical handle or pencil accepts Ø 2.4 mm shafts, the standard of the autoclavable electrode family. To complete the electrosurgery setup, the range offers straight and 45° angled wire tips (GM30330, GM30331, GM30335), hooks (GM30334, GM30344), angled loops (GM30337, GM30347) and Ø 3 mm ball tips (GM30338, GM30339). Maintenance: after each procedure, clean the electrode according to the manufacturer’s instructions, sterilise it in an autoclave recording the number of cycles (maximum 30) and inspect it visually before each use, replacing it if there is any deformation, corrosion or loss of fixation. For volume orders, hospital supply agreements or B2B conditions, contact the technical-commercial team of Cahnos:. For large orders you can request a quote.

Additional information

Longitud

5 cm, 10 cm

Manufacturer reference

30336, 30346

Internal reference number

7

Tip shape

Straight loop (lasso) – straight slip-knot

Shaft diameter

Ø 2.4 mm

Sterilisation

Autoclavable up to 30 cycles

Presentation

Box of 6 units

Device type

Medical device

CND code

Z12010980

GMDN code

44683

Instructions

Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, LT, PL, CZ, HU, HR, RO, GR and Arabic

Application

Monopolar electrosurgery: fine cutting, dissection and localised coagulation

Presentacion

Box of 6

Tipo dispositivo

Medical device

Clase sanitaria

II b

Tipo uso

Reusable

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Prodotto PDF · Label Prodotto PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Autoclavable monopolar electrosurgery electrode with straight loop (lasso) tip · Ø 2.4 mm · Ref. GM30336/GM30346 · Box of 6 units”

Your email address will not be published. Required fields are marked *