We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

BiVac vaporisation electrodes for arthroscopy | REGER Medizintechnik (single-use inserts, with and without suction, series 890/891)

Price on request

BiVac vaporisation insert electrodes for arthroscopy from REGER Medizintechnik: single-use consumables of the BiVac plasma arthroscopy system, designed for vaporisation, ablation and coagulation of soft tissue in the knee, shoulder, elbow and ankle. The range includes vaporisation electrodes with suction (90° and 45°), without suction (90°), 70° and fine and reinforced hook versions at 90°, in lengths of 150 mm and 180 mm; reference 890-7s features a malleable tip. They work with the BiVac bipolar handles and cables (series 92888/92889) and the system’s RF plasma generator. Product on quotation, available in 9 references.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-BIVAC-INSERTOS

Description

BiVac insert electrodes for plasma arthroscopy

The BiVac insert electrodes from REGER Medizintechnik are the single-use consumables of the BiVac plasma arthroscopy system, the reference solution for the treatment of intra-articular soft tissue. Designed to work with the BiVac bipolar handles and cables (series 92888/92889) and the in-house RF plasma generator, they enable precise vaporisation, ablation and coagulation with a controlled thermal effect on adjacent tissues. A complete range of tips —with suction, without suction, angled and hook— to suit each surgical approach and joint.

Technical explanation of the equipment

The BiVac system from REGER concentrates radiofrequency energy at the electrode tip to vaporise soft tissue on contact, maintaining a clean surgical field thanks to the versions with integrated suction, which simultaneously evacuate the medium and the debris generated. The electrodes in the 890/891 series are single-use, ensuring an always-sharp tip, consistent performance and the elimination of the risk of cross-contamination and re-sterilisation costs. They integrate into the modular BiVac arthroscopic plasma system, together with the reusable BiVac handles (refs. 92889-6, 92889-14, 92888-6 and 92888-16) and their adapters for third-party generators (Arthrex, Arthrocare, Ellman, Mitek, BONSS), as well as with the RF plasma generator (refs. 897-10/897-10V).

Technical specifications

Characteristic Description
Brand REGER
Manufacturer REGER Medizintechnik GmbH
System BiVac (Arthroscopy Plasma System)
Product type Single-use arthroscopy electrode inserts
Compatibility BiVac bipolar handles and cables (series 92888/92889); RF plasma generator (897-10/897-10V)
Lengths 150 mm and 180 mm
Measurements Standard and malleable

Available references

REGER reference Model Length Size Reference
890-1s Vaporisation electrode with suction; 90° 150 mm Standard 890-1s
890-6s Vaporisation electrode with suction; 45° 150 mm Standard 890-6s
890-5s Vaporisation electrode with suction; 45° 150 mm Standard 890-5s
890-7s Vaporisation electrode with suction; 45° 150 mm Malleable (Yes) 890-7s
891-2s Vaporisation electrode with suction; 45° 180 mm Standard 891-2s
890-2s Vaporisation electrode; 70° 150 mm Standard 890-2s
890-3s Fine hook; 90° 150 mm Standard 890-3s
890-4s Reinforced hook; 90° 150 mm Standard 890-4s
891-1s Vaporisation electrode without suction; 90° 150 mm Standard 891-1s

Equivalences and cross-references

The 890/891 series of BiVac electrodes is part of the REGER plasma arthroscopy system and works with the BiVac bipolar handles and cables (refs. 92889-6, 92889-14, 92888-6 and 92888-16) and with the system’s RF plasma generator (refs. 897-10/897-10V). According to the manufacturer’s catalogue, the BiVac handles accept reusable adapters for third-party generators: 92390 (Arthrocare), 92387 (Ellman), 92392 (Mitek VUE), 92389 (Mitek Vapr), 92397 (Arthrex) and 92388 (BONSS). No direct 1:1 equivalence tables of these inserts with electrodes from other manufacturers have been identified in reliable sources; to validate compatibility with your generator platform, please consult our technical department before replacing references.

Selection tips and variants of interest

Choose the versions with suction (890-1s to 890-7s and 891-2s) when you need to keep the field clean during vaporisation; the 890-7s, with a malleable tip, is particularly useful for adapting the working angle to complex joint geometries. If you require greater reach, select the 891-2s (45° with suction, 180 mm). The options without suction (891-1s) or angled 70° (890-2s) are suitable for direct vaporisation manoeuvres, while the fine (890-3s) and reinforced (890-4s) hooks, both at 90°, are indicated for cutting and tissue removal. To complete the system, combine these inserts with the BiVac handles (RGR-BIVAC-MANGOS) and, if your platform requires it, with the corresponding adapters. Sale on quotation: request your personalised offer from Cahnos.

Additional information

Modelo

Electrodo de vaporización con aspiración; 90°, Electrodo de vaporización con aspiración; 45°, Electrodo de vaporización; 70°, Gancho fino; 90°, Gancho reforzado; 90°, Electrodo de vaporización sin aspiración; 90°

Longitud

150 mm, 180 mm

Medida

Estándar, Bendable Yes

Referencia

890-1s, 890-6s, 890-5s, 890-7s, 891-2s, 890-2s, 890-3s, 890-4s, 891-1s

Manufacturer

REGER Medizintechnik GmbH

System

BiVac (Arthroscopy Plasma System)

Product type

Single-use arthroscopy electrode inserts

Compatibility

BiVac bipolar handles and cables (series 92888/92889); RF plasma generator (897-10/897-10V)

Lengths

150 mm and 180 mm

Measurements

Standard and malleable

References reger

890-1s, 890-6s, 890-5s, 890-7s, 891-2s, 890-2s, 890-3s, 890-4s, 891-1s

Application

Knee, shoulder, elbow and ankle arthroscopy; vaporisation, ablation and coagulation of soft tissue

Presentation

Under quotation

Tipo uso

Single-use

Reviews

There are no reviews yet.

Be the first to review “BiVac vaporisation electrodes for arthroscopy | REGER Medizintechnik (single-use inserts, with and without suction, series 890/891)”

Your email address will not be published. Required fields are marked *