We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reusable sphere (ball) electrode of 4 mm for monopolar electrosurgery – Ref. 30442, shaft Ø 2.4 mm, length 7 cm, autoclavable up to 20 cycles, box of 5 units

19,95 €

Sphere (ball) electrode of Ø 4 mm for monopolar electrosurgery (Ref. 30442), with a Ø 2.4 mm shaft and 7 cm length. Reusable and autoclavable up to 20 cycles, it is indicated for contact coagulation in open surgery and minor surgery procedures. It is supplied in a box of 5 units and includes multilingual instructions (Spanish included). Medical device class II B, CND L180601 and GMDN 61876. For large orders you can request a quote.

Sales unit: caja de 5
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30442

Description

1. Commercial Introduction

We offer you the sphere (ball) electrode of Ø 4 mm (Ref. 30442), a reusable active tip from the Italian manufacturer’s monopolar electrosurgery line, designed for contact coagulation in the operating theatre, minor ambulatory surgery, general surgery consultations and dermatology services. Its box format with 5 units makes it the ideal replacement solution to complete the reusable instrument stock of your centre, with the guarantee of a leading European manufacturer of medical material.

2. Technical explanation of the electrode

In a monopolar electrosurgery system, the electrosurgical generator sends high-frequency current through the handle or pencil to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed via the neutral (dispersive) plate placed on the patient. The sphere tip concentrates the energy delivery on a reduced surface, making it especially effective for contact coagulation and pinpoint haemostasis of small vessels, with precise control of the thermal effect.

This electrode has a spherical active end of Ø 4 mm mounted on a shaft of Ø 2.4 mm and a total length of 7 cm, compatible with electrode holders and reusable handles that accommodate 2.4 mm shafts. Being autoclavable up to 20 times, it offers a very competitive cost per procedure compared with disposable tips, maintaining consistent coagulation performance in each cycle.

3. Technical Specifications

Reusable sphere (ball) electrode for monopolar electrosurgery, autoclavable up to 20 cycles, with the following characteristics recorded in the manufacturer’s official catalogue:

Characteristic Specification
Electrode type Sphere (ball) electrode Ø 4 mm
Reference number 17
Ball diameter Ø 4 mm
Length 7 cm
Shaft diameter Ø 2.4 mm
Sterilisation Autoclavable – up to 20 times
System Monopolar electrosurgery, contact coagulation
Multilingual instructions GB, FR, IT, ES, PT, DE, NL, SE, LT, PL, CZ, HU, HR, RO, GR and Arabic

Product data

Manufacturer GIMA
Manufacturer reference 30442
Sales unit Box of 5 pieces
Device type Medical device
Device class II B
CND L180601
GMDN 61876
EAN 8033003261026

4. Equivalences and Cross-References

Reference 30442 corresponds to the manufacturer’s original catalogue designation for this reusable sphere electrode of Ø 4 mm (SKU Cahnos GM30442). No reliable sources have been found for a 1:1 equivalence table validated by the manufacturer that cross-references this reference with codes from other brands. Any substitution with tips from other manufacturers must be validated field by field (sphere diameter, length, shaft diameter, handle attachment system and sterilisation protocol) with the technical department of Cahnos before use in tendering.

5. Selection tips and variants of interest

Always check the shaft diameter (Ø 2.4 mm) against the housing of your electrosurgical handle or pencil before placing the order, as well as the fixation system (screw or lock). The Ø 4 mm sphere tip is the recommended option for contact coagulation and precision haemostasis; if your procedure requires a larger contact surface, consult the same family for sphere tips of larger diameter, and for fine dissection, the needle tips of the same reusable range.

Record the number of sterilisation cycles (up to 20 autoclave cycles) and remove the electrode at any sign of deterioration, deformation of the sphere or loss of insulation. For volume orders, hospital supply agreements or validation of alternative models, contact the technical-commercial team of Cahnos. For large orders you can request a quote.

Additional information

Manufacturer reference

30442

Electrode type

Sphere (ball) electrode Ø 4 mm

Reference number

17

Ball diameter

Ø 4 mm

Shaft diameter

Ø 2.4 mm

Sterilisation

Autoclavable up to 20 cycles

System

Monopolar electrosurgery

Use

Contact coagulation

Sales unit

Box of 5 pieces

CND code

L180601

GMDN code

61876

EAN

8033003261026

Instructions

Multilingual (Spanish included)

Presentacion

Box of 5

Tipo dispositivo

Medical device

Clase sanitaria

II b

Longitud

7 cm

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Reusable sphere (ball) electrode of 4 mm for monopolar electrosurgery – Ref. 30442, shaft Ø 2.4 mm, length 7 cm, autoclavable up to 20 cycles, box of 5 units”

Your email address will not be published. Required fields are marked *