Description
1. Introduction
The range of reusable monopolar electrosurgery cables from REGER Medizintechnik GmbH (Germany) is the link that connects the handle or monopolar instrument to the high-frequency (HF) electrosurgical generator. These are durable, highly flexible, high-quality accessories designed to withstand the intensive use of the operating theatre and to maintain stable and safe current transmission intervention after intervention.
Available in a wide variety of connectors and lengths, these cables provide the connection to the main generators on the market and to the most common resectoscopy and arthroscopy systems. A reusable and cost-effective solution for hospitals, clinics, ambulatory surgery centres and minor surgery practices that work with electrosurgical units.
2. Technical explanation of the equipment
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the cable to the active electrode of the handle or instrument, which concentrates the energy at the tip to perform cutting, coagulation or the desired mixed effect; the circuit is closed through the neutral or dispersive plate placed on the patient.
The monopolar cable acts as the transmission path for that energy between the generator socket and the instrument connector. The quality of its materials is decisive: the silver-plated strands on the monopolar pins improve conductivity and offer superior anti-corrosion protection, extending the service life of the accessory and ensuring reliable electrical contact. With a maximum voltage of 4.3 kVp (Umax), these cables are prepared to work with the most demanding high-frequency generators.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Maximum voltage (Umax) | 4.3 kVp |
| Brand | REGER |
| Manufacturer | REGER Medizintechnik GmbH (Germany) |
| Product type | Reusable high-frequency (HF) monopolar electrosurgical cable |
| Construction | Durable, very flexible and high quality |
| Anti-corrosion protection | Silver-plated strands on the monopolar pins |
| Available lengths | 3 m and 5 m |
| Use | Reusable |
| Commercialisation | Under quotation |
Available references
| REGER reference | Length | Connector | Connection to the generator | Compatible with |
|---|---|---|---|---|
| 92002 | 3 m | Female 4mm | Erbe | Erbe |
| 92011 | 3 m | Resectoscope 2mm | Erbe | Erbe |
| 92081 | 3 m | Arthroscopy Hexagon | Erbe | Erbe |
| 92003 | 5 m | Female 4mm | Erbe | Erbe |
| 92012 | 5 m | Resectoscope 2mm | Erbe | Erbe |
| 92061 | 5 m | Resectoscope Storz angled | Erbe | Erbe |
| 92063 | 5 m | Resectoscope Storz straight | Erbe | Erbe |
| 92175 | 5 m | Female 4mm | Martin; Berchtold; Integra | Martin; Berchtold; Integra |
| 92184 | 5 m | Resectoscope 2mm | Martin; Berchtold; Integra | Martin; Berchtold; Integra |
| 92004 | 3 m | Female 4mm | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92009 | 3 m | Resectoscope 2mm | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92089 | 3 m | Resectoscope Olympus 3mm | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92042 | 3 m | Resectoscope Storz angled | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92062 | 3 m | Resectoscope Storz straight | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92005 | 5 m | Female 4mm | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92010 | 5 m | Resectoscope 2mm | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92090 | 5 m | Resectoscope Olympus 3mm | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92050 | 5 m | Resectoscope Storz angled | Erbe T-Serie / International 4mm | Erbe T-Serie / International 4mm |
| 92051 | 3 m | Female 4mm | Valleylab | Valleylab |
| 92013 | 3 m | Resectoscope 2mm | Valleylab | Valleylab |
| 92105 | 5 m | Female 4mm | Valleylab | Valleylab |
| 92014 | 5 m | Resectoscope 2mm | Valleylab | Valleylab |
| 92203 | 3 m | Female 4mm | Ellman | Ellman |
Data verified against the official catalogue of REGER Medizintechnik GmbH (HF surgery system > HF cables > monopolar cables) and the Cahnos-Catalog-Loader load.
4. Equivalences and Cross-References
The reference RGR-CABLE-MONO is the commercial family with which Cahnos registers this range of monopolar cables, and the numerical references 92002, 92011, 92081, 92003, 92012, 92061, 92063, 92175, 92184, 92004, 92009, 92089, 92042, 92062, 92005, 92010, 92090, 92050, 92051, 92013, 92105, 92014 and 92203 are the original codes from the manufacturer’s catalogue (in the shop they are identified with the prefix RGR-).
No reliable source has been found for a 1:1 equivalence table validated by the manufacturer that cross-references these codes with those of other brands. Monopolar cables from other manufacturers (Erbe, Valleylab/Medtronic, Berchtold, Martin, BOWA or Aesculap) are comparable only at category level and are not interchangeable without field-by-field verification: connector type on the generator side, instrument connector and length. Consult our technical-commercial department before using any equivalence in tenders or substitutions.
5. Selection tips and variants of interest
According to the generator: choose the reference whose connector matches the socket of your equipment. For Erbe generators: refs. 92002, 92003, 92011, 92012, 92061, 92063 and 92081. For Erbe T-Serie / International 4 mm: refs. 92004, 92005, 92009, 92010, 92089, 92090, 92042, 92050, 92062 and 92051. For Valleylab: refs. 92051, 92013, 92105 and 92014. For Martin, Berchtold and Integra equipment: refs. 92175 and 92184. For Ellman generators: ref. 92203.
According to the instrument: the 4 mm female connector is the most common standard for monopolar handles and electrodes; the 2 mm resectoscope, 3 mm Olympus resectoscope and Storz resectoscope (straight and angled) variants cover resectoscopy and arthroscopy systems. Reference 92081 with hexagonal arthroscopy connector is aimed at arthroscopic instruments.
According to length: the 5 m versions (92003, 92012, 92061, 92063, 92175, 92184, 92005, 92010, 92090, 92050, 92105, 92014) offer a greater working radius around the operating table; the 3 m versions facilitate more contained cable management.
Periodically inspect the cable and connection points (no cuts, kinks or deterioration of the insulation) and replace any unit that shows signs of damage. For volume orders, tenders or B2B hospital supply conditions, contact the technical-commercial team at Cahnos. This product is sold on a quotation basis.