We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reusable connection adapters for HF/RF electrosurgery REGER – References 92395 and 92396 (Valleylab/International to Erbe, Storz, Martin, Berchtold and Integra)

Price on request

Connection adapters from the house of REGER Medizintechnik GmbH for high-frequency (HF) and radiofrequency (RF) electrosurgery systems. Reusable and autoclavable at 134 °C parts that allow connecting monopolar instruments with a Valleylab/International connector to Erbe, Storz, Martin, Berchtold and Integra generators, expanding the compatibility of your electrosurgical unit fleet without replacing handpieces or equipment. Supplied as one unit per package, with 4 mm dimensions and a maximum voltage of 4.3 kVp. Marketed on quotation: consult our technical-commercial team.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-ADAPTADOR-HF

Description

1. Introduction

We offer you the connection adapters from the REGER brand for electrosurgery, the ideal solution for integrating the monopolar instruments in your operating theatre with generators from different manufacturers. Designed and manufactured by REGER Medizintechnik GmbH (Germany), these adapters solve the transition between the standard Valleylab/International connector and the sockets of Erbe, Storz, Martin, Berchtold and Integra equipment, without the need to replace the handpieces or the electrosurgical generator.

These are reusable, robust accessories suitable for sterilisation in an autoclave at 134 °C, designed for continuous use in hospitals, private clinics and ambulatory surgery centres that manage mixed equipment fleets.

2. Technical explanation of the equipment

In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends the high-frequency current through the handpiece cable to the active electrode, and the circuit is closed via the neutral or dispersive plate on the patient. For energy transmission to be safe and efficient, the instrument connector and the generator socket must be compatible; however, each manufacturer has historically consolidated its own connection standards.

These REGER adapters act as an electrical and mechanical bridge: at one end they accept the Valleylab/International type connector and at the other they adapt to the socket of the destination generator (Erbe, Storz, Martin, Berchtold or Integra). Being reusable and autoclavable, they are incorporated into the instrument rotation of the department and offer a stable connection that preserves the cutting and coagulation performance of the set.

3. Technical Specifications

Data verified against the official catalogue of REGER Medizintechnik GmbH (HF surgery system > HF electrodes and adapters) and the Cahnos-Catalog-Loader load.

Manufacturer’s specifications

Characteristic Value
Measurements 4 mm
Maximum voltage (Umax) 4.3 kVp

Product data

Characteristic Value
Brand REGER
Manufacturer REGER Medizintechnik GmbH (Germany)
Product type Connection adapter for electrosurgery (HF/RF)
Use Reusable
Sterilisation Autoclavable (134 °C)
Presentation 1 unit per pack
System High-frequency (HF) and radiofrequency (RF) surgery
Sale Under quotation

Available references

REGER reference Connector Units per pack Compatible with
92395 Valleylab, Int. to Erbe, Storz 1 Valleylab, Int.; Erbe; Storz
92396 Valleylab, Int. to Martin, Berchtold, Integra 1 Valleylab, Int.; Martin; Berchtold; Integra

4. Equivalences and Cross-References

References 92395 and 92396 are the original codes from the REGER Medizintechnik GmbH catalogue; Cahnos markets them with the double coding RGR-92395 and RGR-92396 (same product, two notations). No reliable source has been found with a 1:1 equivalence table validated by the manufacturer that cross-references these references with codes from other adapter brands.

Connection adapters from other manufacturers are comparable only at category level and should not be considered interchangeable without field-by-field verification: pin configuration, connection diameter, maximum voltage and fixing system. Before any replacement or tender, consult our technical-commercial department. Within the same family of HF adapters from REGER, reference RGR-92399 covers the conversion from 6-pin ARTro to 3-pin Valleylab/International.

5. Selection tips and variants of interest

First identify the connector type of your instrument and the socket of your electrosurgical generator. If your monopolar handpiece or cable uses a Valleylab/International connector and you have Erbe or Storz generators, select reference 92395; if your equipment is from Martin, Berchtold or Integra, choose reference 92396. Both are supplied as one unit per package and are reusable and autoclavable at 134 °C.

For other connection configurations (3.2 mm, 4 mm, 6 mm, 8 mm connectors or ARTro systems), consult the full range of electrosurgery adapters and accessories available in the Cahnos catalogue. For institutional volumes, operating theatre fittings or tenders with B2B conditions, contact our technical-commercial team. This product is marketed on quotation.

Additional information

Conector

Valleylab, Int. to Erbe, Storz, Valleylab, Int. to Martin, Berchtold, Integra

Units per pack

1

Measurements

4 mm

Maximum voltage (Umax)

4.3 kVp

REGER reference

92395, 92396

Manufacturer

REGER Medizintechnik GmbH

Product type

Connection adapter for HF/RF electrosurgery

Sterilisation

Autoclavable (134 °C)

System

High-frequency (HF) and radiofrequency (RF) surgery

Maximum voltage

4.3 kVp (Umax)

Presentation

1 unit per pack

Compatibility

Valleylab/International; Erbe; Storz; Martin; Berchtold; Integra

References

92395, 92396

Tipo uso

Reusable

Reviews

There are no reviews yet.

Be the first to review “Reusable connection adapters for HF/RF electrosurgery REGER – References 92395 and 92396 (Valleylab/International to Erbe, Storz, Martin, Berchtold and Integra)”

Your email address will not be published. Required fields are marked *