FIAB connection cable for reusable neutral plate, 500 cm, Valleylab-type connector with REM system (ESU with REM) · Ref. F7923

Price on request

Original connection cable FIAB (ref. F7923) for reusable silicone neutral plates, with 500 cm length and Valleylab-type connector with REM system (Return Electrode Monitoring). Designed to complete the monopolar circuit by connecting the return plate to the electrosurgical unit in generators with a Valleylab socket and return electrode control, it guarantees a stable, low current density return path. Compatible with reusable FIAB plates with 4 mm socket (F7930 with REM and F7915 without REM). Ideal replacement solution for operating theatres, minor surgery clinics, dermatology, dentistry and veterinary clinics seeking to reduce single-use consumables. Sold as a single unit, on quotation. Ref. FIAB-F7923.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F7923
Brand
FIAB

Description

Product presentation

We present the original FIAB connection cable for reusable neutral plates, an essential reference for completing the monopolar circuit of your electrosurgery with maximum reliability. With a length of 500 cm and a Valleylab-type connector with REM system (ESU with REM), this cable is indicated for electrosurgical generators with a Valleylab-type return socket and return electrode control, and allows the return plate to be reused in multiple procedures after cleaning and disinfection.

It is the usual choice in operating theatres, minor surgery clinics, dermatology, dentistry and veterinary clinics that work with equipment with a Valleylab-type connector and wish to reduce healthcare waste and the recurring cost of single-use electrodes, while maintaining a safe and stable return contact.

Technical explanation

In monopolar electrosurgery, the high-frequency current leaves through the active electrode (pencil), passes through the patient’s tissue and must return to the generator via a low current density path: the neutral plate or return electrode. The quality of that path depends both on the plate and on the cable that connects it to the electrosurgical unit.

The REM system (Return Electrode Monitoring) is the return electrode monitoring technology associated with Valleylab-type generators and other equipment with split plate control: the generator continuously monitors contact impedance and blocks emission with an alarm if it detects poor contact. This F7923 cable, with a Valleylab-type connector with REM, guarantees that monitoring when working with reusable FIAB neutral plates equipped with a 4 mm socket, ensuring a low and stable contact impedance, an essential condition to avoid current density concentrations that could lead to patient burns.

It is a reusable accessory: it must be cleaned after each use, visually inspected (no cuts, cracks or deterioration of the insulation) and its continuity periodically verified before each procedure.

Technical specifications

Characteristic Value
Reference FIAB F7923
Packaging Single unit
Units per box (web) 1
Characteristic Value
Brand FIAB (FIAB SpA, Vicchio, Florence, Italy)
Product type Connection cable for reusable neutral plate (return electrode)
Length 500 cm
Connector Valleylab type (ESU with REM)
Compatibility Electrosurgical generators with Valleylab-type socket and REM system; reusable plates FIAB with 4 mm socket (F7930 with REM, F7915 without REM)
Type of use Reusable

Available references

Reference Description Length
F7923 Valleylab-type cable (ESU with REM) 500 cm

Equivalences and cross-references

This cable belongs to the FIAB range of connection cables for reusable neutral plates. Reference F7923 corresponds to the version for equipment with REM system; its complementary variant within the same family is F7923/F (Valleylab-type cable for ESU without REM). For disposable neutral plates, the equivalent FIAB family consists of references F7903 (Valleylab type with REM) and F7903/F (Valleylab type without REM).

There is no official equivalence table validated by the manufacturer with cables from other brands. Before any replacement, confirm with the technical department the compatibility of the connector with your generator (plug type and presence or absence of REM control).

Selection tips and variants of interest

  • Check your equipment’s system: reference F7923 is valid for generators with a Valleylab-type connector and REM control. If your electrosurgical unit does not have return electrode monitoring, consider reference F7923/F (ESU without REM).
  • Compatible plate: use it with reusable FIAB neutral plates with 4 mm socket (F7930 with REM system or F7915 without REM) to ensure a stable return contact.
  • Other connector configurations: if your equipment uses a single or double 4 mm plug, consider references F7922/4 and F7922/24; if it uses a 6.3 mm mono jack connector, references F7922 (universal) or F7924 (for ERBE, ACC, ICC, VIO and T series).
  • Maintenance: clean the cable after each use with the products indicated by the manufacturer, dry it completely and avoid sharp bends; check the insulation and continuity before each procedure and replace it at any sign of degradation.
  • Institutional purchases: for operating theatre fittings or volume orders with special B2B conditions, consult our technical-commercial department.

Additional information

Brand

FIAB

Packaging

Single unit

Reference

F7923

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Product type

Connection cable for reusable neutral plate (return electrode)

Connector

Valleylab type (ESU with REM)

Compatibility

Electrosurgical generators with Valleylab-type socket and REM system; reusable plates FIAB with 4 mm socket (F7930 with REM, F7915 without REM)

Presentation

Single unit

Units per box

1

Longitud

500 cm

Tipo uso

Reusable

Reviews

There are no reviews yet.

Be the first to review “FIAB connection cable for reusable neutral plate, 500 cm, Valleylab-type connector with REM system (ESU with REM) · Ref. F7923”

Your email address will not be published. Required fields are marked *