We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Double explosion-proof and waterproof pedal for electrosurgical unit Diatermo MB 240 and MB 380 – CUT and COAG functions from the foot (Ref. 30603)

389,50 €

Double explosion-proof (flameproof) and waterproof pedal for the high-frequency electrosurgery units Diatermo MB 240 and MB 380. With two activation zones, it allows selecting the cutting (CUT) and coagulation (COAG) functions from the foot without releasing the instrument or taking your eyes off the operative field. Its sealed and flameproof construction is designed for environments with a risk of explosive atmospheres and to withstand liquids and splashes in the operating theatre, ensuring reliable and repeatable activation throughout the procedure. Original manufacturer replacement: reference 30603 (SKU GM30603), sales unit 1 pc. Product with no published price:; consult our technical-commercial team for B2B conditions. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30603

You will also find it in

Description

1. Commercial Introduction

The double explosion-proof pedal is the reference hands-free activation accessory for working with the high-frequency electrosurgery units Diatermo MB 240 and MB 380. It allows the surgeon to start cutting and coagulation directly with the foot, without releasing the electrode holder handle or taking their eyes off the operative field, with maximum comfort, precision and safety. Manufactured with a sealed, flameproof and waterproof housing, it is designed to withstand the demanding environment of the operating theatre: presence of liquids, splashes and reinforced safety conditions against potentially explosive atmospheres.

2. Technical explanation of the accessory

In a high-frequency electrosurgery system, energy activation can be performed from the electrode holder handle or via a foot pedal. This double footswitch offers an ergonomic and safe alternative: it has two independent activation areas that allow switching between CUT (cutting) and COAG (coagulation) functions without the need for manual buttons, freeing both hands for handling the electrode, forceps or surgical instruments. Its explosion-proof protection reduces the risk of ignition in environments with flammable agents, while the sealed design protects the switching electronics against moisture and splashes, facilitates surface cleaning and disinfection between procedures and ensures reliable and reproducible activation, a key element for the precision of cutting and coagulation.

3. Technical Specifications

Characteristic Specification
Accessory type Double explosion-proof and waterproof pedal (footswitch) for electrosurgery
Functions Selection from the pedal of CUT (cutting) and COAG (coagulation) functions
Protection Explosion-proof (flameproof) and waterproof (sealed)
Activation Via foot pedal (hands-free), as an alternative to the electrode holder handle
Compatibility Electrosurgical units Diatermo MB 240 and MB 380
Manufacturer reference 30603

Product data

Field Value
Manufacturer GIMA
Sales unit 1 pc
Device type No medical device
EAN 8033638321652

4. Equivalences and Cross-References

No official equivalence table validated by the manufacturer has been found in reliable sources that cross-references reference 30603 with codes from other manufacturers, so no substitution should be treated as interchangeable 1:1 without validation from the technical department. Within the ecosystem, this double explosion-proof pedal is associated with the Diatermo MB 240 and MB 380 series equipment, and is related to the family of sealed MB pedals: reference 30577 (sealed MB pedal with 2 m cable), reference 30578 (sealed MB pedal with 3 m cable) and the sealed MB pedal 30608 included in the Diatermo MB 300/400 TOUCH equipment. Before purchasing a replacement, always verify the connector, the number of activation zones and the configuration of your generator with the technical department of Cahnos.

5. Selection tips and variants of interest

Check the compatibility of the connector and the pedal layout with your electrosurgical unit before purchase: this double explosion-proof model is associated with the Diatermo MB 240 and MB 380 units, while the Diatermo 50, 80, MB 120, 122, 132, 160, 200 and 202 series use the sealed MB pedals from references 30577 and 30578. If your equipment operates in an environment with a risk of explosive atmospheres, the flameproof nature of this pedal is an essential safety requirement. Keep the pedal in a dry and stable area of the operating theatre floor and periodically check the integrity of the cable and the sealed housing; if any damage occurs, replace the accessory with an original spare part. To complete the equipment of your electrosurgery system, Cahnos offers handles and pencils with buttons, electrodes, neutral plates with their cable and other accessories from the electrosurgery range. Product with no published price: indicate your equipment and application to our technical-commercial team to receive advice and B2B conditions without obligation.

Additional information

Manufacturer reference

30603

Pedal type

Dual: selection of CUT and COAG functions from the foot

Protection

Explosion-proof (flameproof) and waterproof (sealed)

Compatibility

Electrosurgical units Diatermo MB 240 and MB 380

Device type

No medical device

EAN

8033638321652

Presentacion

Unit

Documentation

📄 DatasheetEnglish PDF
📜 CertificatesDispositivo non medico PDF

Reviews

There are no reviews yet.

Be the first to review “Double explosion-proof and waterproof pedal for electrosurgical unit Diatermo MB 240 and MB 380 – CUT and COAG functions from the foot (Ref. 30603)”

Your email address will not be published. Required fields are marked *