Diatermo MB 200 Touch Electrosurgical Unit – High-frequency monopolar and bipolar electrosurgery equipment, 200 W, touch screen (Ref. 30693)

4.085,00 €

Electrosurgical unit of high frequency for precision surgery and microsurgery in monopolar and bipolar mode, with a maximum power of 200 W and touch screen control. It incorporates pure cut (CUT), blend (BLEND), forced coagulation, soft coagulation, fulguration and bipolar cut, coagulation and sealing functions, with constant monitoring of the neutral electrode and of the delivered power via microcontroller. Includes flexible steel neutral plate with cable, kit of 10 standard electrodes Ø 2.4 mm, reusable handle with push buttons, waterproof footswitch, power cable and stand. Unit, manufactured in Italy, classified as a class IIb medical device and intended for emergencies, neurosurgery, respiratory medicine, endoscopy, ENT, urology, gastroenterology, vascular surgery, gynaecology, general surgery and veterinary.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30693

You will also find it in

Description

1. Product Presentation

The Diatermo MB 200 Touch is a professional high-frequency electrosurgical unit, designed for precision surgery and microsurgery procedures in monopolar and bipolar mode, without tissue alterations. It can supply high-frequency operating power even in programmable times down to hundredths of a second, achieving clean, reproducible and safe surgical work.

Its touchscreen control, digital readout of delivered power and supervision of operating functions via microcontroller guarantee absolute reliability of working conditions. It is a unit suitable for operating theatres and general surgery departments and the various specialties, combining ergonomic and safety solutions normally reserved for high-end equipment. Made in Italy

2. Technical explanation of the equipment and procedure

The electrosurgical unit generates high-frequency radiofrequency current (360 kHz) that is applied to the tissue through the active electrode (handle or pencil). Depending on the waveform and selected mode, the predominant effect is cutting, coagulation or mixed, while the neutral (dispersive) plate placed on the patient closes the return circuit. The neutral electrode connection and plate/patient contact control are constantly monitored, and the unit has a self-check on start-up.

The unit allows pure cut mode (CUT), mixed cut-coagulation (BLEND), incisions with reduced eschar production (ENHANCED), superficial coagulation (FORCED COAG), deep coagulation without necrosis (SOFT COAG), bipolar cut, coagulation and sealing (BIPOLAR CUT, BIPOLAR COAG, BIPOLAR SEALING) and fulguration (FULGURATION). The ability to control output functions and power from the electrode-holding handle itself allows the procedure to be performed without taking one’s eyes off the surgical field. The software offers a simple, functional and intuitive working experience: with a single touch of a finger the screen is customised, work settings, cutting or coagulation power are modified and each function of the unit is managed.

3. Technical Specifications

Maximum power per output mode:

Mode Maximum power Load
Pure cut (PURE CUT) 200 W 300 Ohm
Blend (BLEND) 150 W 300 Ohm
ENHANCED 150 W 300 Ohm
Forced coagulation (FORCED COAG) 150 W 200 Ohm
Soft coagulation (SOFT COAG) 100 W 200 Ohm
Fulguration (FULGURATION) 100 W 1000 Ohm
Bipolar sealing (BIPOLAR SEALING) 200 W 50 Ohm
Bipolar coagulation (BIPOLAR COAG) 120 W 50 Ohm
Bipolar cut (BIPOLAR CUT) 120 W 50 Ohm

General characteristics of the unit:

Characteristic Specification
RF power pulse Emission time 10 ms – 30 s · interval 1 – 30
Patient circuit F
Selectable input voltage 100 – 240 VAC · 750 VA
Working frequency 360 kHz
Dimensions (W x H x D) · Weight 370 x 145 x 300 mm · 6 kg
Controls Patient/plate circuit monitoring, output power monitoring, self-check
Safety EN60601-1 · EN60601-1-2 · EN60601-2-2
Electrical classification I CF MDD 93/42 / CE · Class IIb

Included accessories:

  • Flexible steel neutral plate with cable (30555 + 30560)
  • Kit of 10 short standard electrodes Ø 2.4 mm (30500)
  • 5 m power cable
  • Support for handle and electrodes
  • Reusable handle with push buttons (30536)
  • Waterproof pedal (30577)

Product data:

Manufacturer GIMA
Sales unit 1 pc
Device type Medical device
Device class II B
CND Z12010902
GMDN 44776
EAN 8033638325315

4. Equivalences and Cross-References

No equivalence table validated by the manufacturer for this model has been found in reliable sources. The manufacturer’s accessory references associated with this unit are 30555, 30560, 30500, 30536 and 30577 (neutral plate, electrode kit, reusable handle and waterproof pedal). The Diatermo MB 200 Touch belongs to the category of high-frequency electrosurgical generators for hospital use comparable, at category level, with equipment from other manufacturers in the sector; before any replacement or direct comparison, the power per mode, working frequency, electrical classification and accessory compatibility with the installed unit must be verified field by field.

5. Selection tips and variants of interest

Check that the neutral plate and the pencil are compatible with the connection standard of your electrosurgery equipment; this unit is supplied with a flexible steel neutral plate with cable, reusable handle with push buttons (30536), kit of 10 standard electrodes (30500) and waterproof footswitch (30577). If your facility works with single-use pencil-type consumables or disposable plates, contact our technical-commercial department regarding compatibility with the accessories in the electrosurgery catalogue. Unit indicated for emergencies, neurosurgery, respiratory medicine, endoscopy, first aid, ear, nose and throat (ENT), urology, gastroenterology, vascular surgery, veterinary and gynaecology; usable in orthopaedics, transurethral resection (TUR), paediatric surgery, general surgery and plastic surgery. Product without published price: For large orders you can request a quote.

Additional information

Manufacturer reference

30693

Product type

Electrosurgical unit (high-frequency electrosurgery equipment)

Modality

Monopolar and bipolar

Maximum power

200 W (PURE CUT) · 200 W (BIPOLAR SEALING)

Working frequency

360 kHz

Input voltage

100 – 240 VAC · 750 VA

RF power pulse

Emission 10 ms – 30 s · interval 1 – 30

Patient circuit

F

Measurements

370 x 145 x 300 mm (W x H x D)

Weight

6 kg

Controls

Patient/plate monitoring, power monitoring, self-check

Safety

EN60601-1 · EN60601-1-2 · EN60601-2-2

Electrical classification

I CF MDD 93/42 / CE: II B

Display

Touch

CND code

Z12010902

GMDN code

44776

EAN

8033638325315

Included accessories

Flexible steel neutral plate with cable (30555+30560), kit of 10 electrodes Ø 2.4 mm (30500), 5 m power cable, support, reusable handle with push buttons (30536), waterproof pedal (30577)

Intended use

Emergency, neurosurgery, pulmonology, endoscopy, ENT, urology, gastroenterology, vascular surgery, gynaecology, veterinary, orthopaedics, TUR, paediatric/general/plastic surgery

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Pais fabricacion

Italy

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Diatermo MB 200 Touch Electrosurgical Unit – High-frequency monopolar and bipolar electrosurgery equipment, 200 W, touch screen (Ref. 30693)”