Description
1. Commercial Introduction
The standard reusable bipolar forceps from REGER Medizintechnik are the ideal solution for haemostasis and precision coagulation in open surgery and microsurgery. Designed for continuous use in the operating theatre, they offer an excellent balance between durability, ergonomic handling and cost per procedure compared with single-use alternatives. Being reusable, they help reduce both material consumption and the environmental impact of the centralised sterilisation service, while maintaining the same reliability procedure after procedure.
2. Technical Explanation
In bipolar electrosurgery, the high-frequency current flows only between the two branches of the forceps, so no patient plate is required and the risk of thermal injury to adjacent tissues is minimised. These forceps are compatible with high-frequency (HF) and radiofrequency (RF) generators, transmitting energy from the equipment to the coagulation point with high-grade insulation that protects both the professional and the patient. They feature a European flat plug with guide pin, which facilitates a secure and standardised connection to the generator’s bipolar cable. Their maximum working voltage is 500 Vp, within the usual ranges of bipolar electrosurgery.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Maximum voltage (Umax) | 500 Vp |
| Type | Standard reusable bipolar forceps |
| Application | High-frequency (HF) and radiofrequency (RF) generators |
| Connection | European flat plug / guide pin |
| Insulation | High-grade insulation |
| Units per pack | 1 |
Available references
| REGER reference | Shape | Tip width | Length | Tip length | Units per pack | Compatible with |
|---|---|---|---|---|---|---|
| 95042 | Straight, angled tip | 1.0 mm | 145 mm | 8 mm | 1 | |
| 95036 | Straight, angled tip | Needle | 165 mm | 6 mm | 1 | |
| 95013 | Straight, angled tip | 0.5 mm | 165 mm | 8 mm | 1 | |
| 95014 | Straight, angled tip | 1.0 mm | 165 mm | 8 mm | 1 | |
| 95187 | Straight, angled tip | Needle | 180 mm | 6 mm | 1 | |
| 95089 | Straight, angled tip | 0.5 mm | 180 mm | 8 mm | 1 | |
| 95090 | Straight, angled tip | 1.0 mm | 180 mm | 8 mm | 1 | |
| 95088 | Straight, angled tip | 2.0 mm | 180 mm | 8 mm | 1 | |
| 95103 | Straight, angled tip | Needle | 195 mm | 8 mm | 1 | |
| 95104 | Straight, angled tip | 0.5 mm | 195 mm | 8 mm | 1 | |
| 95001 | Straight, angled tip | 1.0 mm | 195 mm | 8 mm | 1 | |
| 95007 | Straight, angled tip | 2.0 mm | 195 mm | 8 mm | 1 | |
| 95058 | Straight, angled tip | 2.0 mm fluted | 195 mm | 8 mm | 1 | |
| 95128 | Straight, angled tip | Needle | 225 mm | 8 mm | 1 | |
| 95122 | Straight, angled tip | 0.5 mm | 225 mm | 8 mm | 1 | |
| 95024 | Straight, angled tip | 1.0 mm | 225 mm | 8 mm | 1 | |
| 95125 | Straight, angled tip | 2.0 mm | 225 mm | 8 mm | 1 | |
| 95116 | Bayonet, straight tip | Needle | 165 mm | 6 mm | 1 | |
| 95017 | Bayonet, straight tip | 0.5 mm | 165 mm | 6 mm | 1 | |
| 95018 | Bayonet, straight tip | 1.0 mm | 165 mm | 6 mm | 1 | |
| 95194 | Bayonet, straight tip | Needle | 180 mm | 6 mm | 1 | |
| 95092 | Bayonet, straight tip | 0.5 mm | 180 mm | 6 mm | 1 | |
| 95091 | Bayonet, straight tip | 1.0 mm | 180 mm | 6 mm | 1 | |
| 95093 | Bayonet, straight tip | 2.0 mm | 180 mm | 8 mm | 1 | |
| 95008 | Bayonet, straight tip | Needle | 195 mm | 6 mm | 1 | |
| 95109 | Bayonet, straight tip | 0.5 mm | 195 mm | 6 mm | 1 | |
| 95002 | Bayonet, straight tip | 1.0 mm | 195 mm | 6 mm | 1 | |
| 95034 | Bayonet, straight tip | 2.0 mm | 195 mm | 8 mm | 1 | |
| 95059 | Bayonet, straight tip | 2.0 mm fluted | 195 mm | 8 mm | 1 | |
| 95045 | Bayonet, straight tip | Needle | 220 mm | 6 mm | 1 | |
| 95031 | Bayonet, straight tip | 0.5 mm | 220 mm | 6 mm | 1 | |
| 95131 | Bayonet, straight tip | 1.0 mm | 220 mm | 6 mm | 1 | |
| 95132 | Bayonet, straight tip | 2.0 mm | 220 mm | 8 mm | 1 | |
| 95197 | Bayonet, straight tip | 0.5 mm | 240 mm | 6 mm | 1 | |
| 95196 | Bayonet, straight tip | 1.0 mm | 240 mm | 6 mm | 1 | |
| 95204 | Bayonet, straight tip | 2.0 mm | 240 mm | 6 mm | 1 | |
| 95019 | Straight | Needle | 110 mm | 6 mm | 1 | |
| 95020 | Straight | 0.5 mm | 110 mm | 6 mm | 1 | |
| 95023 | Straight, angled tip | Needle | 110 mm | 6 mm | 1 | |
| 95021 | Straight, angled tip | 0.5 mm | 110 mm | 6 mm | 1 | |
| 95038 | Straight | 1.0 mm | 145 mm | 8 mm | 1 | HF and RF generators |
| 95011 | Straight | Needle | 165 mm | 6 mm | 1 | HF and RF generators |
| 95170 | Straight | 0.5 mm | 165 mm | 8 mm | 1 | HF and RF generators |
| 95039 | Straight | 1.0 mm | 165 mm | 8 mm | 1 | HF and RF generators |
| 95027 | Straight | 2.0 mm | 165 mm | 8 mm | 1 | HF and RF generators |
| 95181 | Straight | Needle | 180 mm | 6 mm | 1 | HF and RF generators |
| 95171 | Straight | 0.5 mm | 180 mm | 8 mm | 1 | HF and RF generators |
| 95180 | Straight | 1.0 mm | 180 mm | 8 mm | 1 | HF and RF generators |
| 95178 | Straight | 2.0 mm | 180 mm | 8 mm | 1 | HF and RF generators |
| 95112 | Straight | Needle | 195 mm | 8 mm | 1 | HF and RF generators |
| 95037 | Straight | 0.5 mm | 195 mm | 8 mm | 1 | HF and RF generators |
| 95040 | Straight | 1.0 mm | 195 mm | 8 mm | 1 | HF and RF generators |
| 95029 | Straight | 2.0 mm | 195 mm | 8 mm | 1 | HF and RF generators |
| 95057 | Straight | 2.0 mm fluted | 195 mm | 8 mm | 1 | HF and RF generators |
| 95113 | Straight | Needle | 225 mm | 8 mm | 1 | HF and RF generators |
| 95172 | Straight | 0.5 mm | 225 mm | 8 mm | 1 | HF and RF generators |
| 95041 | Straight | 1.0 mm | 225 mm | 8 mm | 1 | HF and RF generators |
| 95030 | Straight | 2.0 mm | 225 mm | 8 mm | 1 | HF and RF generators |
| 95207 | Straight | 2.0 mm | 260 mm | 8 mm | 1 | HF and RF generators |
| 95026 | Bayonet, angled tip | 1.0 mm | 195 mm | 6 mm | 1 | |
| 95063 | Bayonet, angled tip | 1.0 mm | 220 mm | 6 mm | 1 | |
| 95203 | Bayonet, angled tip | 1.0 mm | 240 mm | 6 mm | 1 | |
| 95065 | Bayonet, sharply angled tip | 1.0 mm | 195 mm | 6 mm | 1 | |
| 95067 | Bayonet, sharply angled tip | 1.0 mm | 220 mm | 6 mm | 1 | |
| 95064 | Bayonet, sharply angled tip | 1.0 mm | 240 mm | 6 mm | 1 |
4. Equivalences and Cross-References
The references 95042, 95036, 95013, 95014, 95187, 95089, 95090, 95088, 95103, 95104, 95001, 95007, 95058, 95128, 95122, 95024, 95125, 95116, 95017, 95018, 95194, 95092, 95091, 95093, 95008, 95109, 95002, 95034, 95059, 95045, 95031, 95131, 95132, 95197, 95196, 95204, 95019, 95020, 95023, 95021, 95038, 95011, 95170, 95039, 95027, 95181, 95171, 95180, 95178, 95112, 95037, 95040, 95029, 95057, 95113, 95172, 95041, 95030, 95207, 95026, 95063, 95203, 95065, 95067 and 95064 are the original catalogue designations from the manufacturer REGER for this family of standard bipolar forceps (SKU Cahnos: RGR-PINZA-BIPOLAR and RGR-XXXXX variants). Featuring a European flat plug with guide pin, these forceps are compatible with bipolar cables with European connector such as those from the GIMA range (refs. GM30632, GM30640, GM30643 and GM30617) and with HF/RF electrosurgical generators with European forceps input from leading brands. No validated 1:1 equivalence table with codes from other manufacturers has been found in reliable sources; before any substitution, the shape, tip width and length, total length and connector compatibility with the installed generator must be verified. Please consult our technical-commercial department to validate the most suitable reference for your equipment fleet.
5. Selection tips and variants of interest
To choose the correct reference, first consider the shape: straight forceps (references 95019, 95020, 95038, 95011, 95170, 95039, 95027, 95181, 95171, 95180, 95178, 95112, 95037, 95040, 95029, 95057, 95113, 95172, 95041, 95030 and 95207), straight with angled tip (series 95042, 95036, 95013, 95014, 95187, 95089, 95090, 95088, 95103, 95104, 95001, 95007, 95058, 95128, 95122, 95024, 95125, 95023 and 95021), bayonet with straight tip (series 95116, 95017, 95018, 95194, 95092, 95091, 95093, 95008, 95109, 95002, 95034, 95059, 95045, 95031, 95131, 95132, 95197, 95196 and 95204), bayonet with angled tip (95026, 95063 and 95203) and bayonet with highly angled tip (95065, 95067 and 95064). Next, select the tip width: needle for maximum precision and microsurgery, 0.5 mm and 1.0 mm for fine haemostasis, 2.0 mm for standard field coagulation and 2.0 mm serrated for better tissue grip. Finally, adjust the total length (from 110 mm to 260 mm) according to the depth of the surgical field and the surgeon’s preference. Complete your system with bipolar cables with European (EU) connector and always verify connector compatibility with your generator. Product without published price: please consult our technical-commercial team at Cahnos for B2B terms, delivery times and advice on configuring the range.





Reviews
There are no reviews yet.