Description
1. Reusable electrosurgical pencil handle for the operating theatre
We offer you the electrosurgical pencil handle ORION PLUS (ref. 30539), a professional reference from the manufacturer’s electrosurgery line. Designed for continuous use in the operating theatre, major ambulatory surgery, minor surgery clinics and general surgery departments, it combines an autoclavable body with two large ‘click’ type push buttons, a 3-metre silicone cable and an included blade electrode. Its reusable design, with up to 100 autoclave cycles, offers a very competitive cost per procedure compared with disposable pencils and reduces clinical waste in the surgical block.
2. Technical explanation of the equipment and procedure
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil to the active electrode —the blade mounted on the handle—, which concentrates the energy at the point of contact with the tissue; the circuit is closed through the neutral (dispersive) plate placed on the patient. Depending on the waveform selected on the generator, the effect is cutting, coagulation or mixed.
This handle incorporates manual control with 2 large ‘click’ type push buttons whose activation allows immediate recognition of activation, and has a connection compatible with Valleylab type sockets (3 pins), the most widespread in electrosurgical generators on the market. Its screw fixation system (screw clamp) not only guarantees a safe and stable electrical contact with the electrode, but also adapts to different shaft diameters within the family. The handle offers high insulation that protects against liquid ingress or damage during use and cleaning, and can be sterilised in an autoclave up to 100 times, while the included blade electrode withstands up to 20 cycles.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 30539 (SKU Cahnos: GM30539) |
| Product type | Autoclavable, reusable electrosurgical pencil handle |
| Activation | 2 large ‘click’ type push buttons |
| Cable | Silicone, 3 metres in length |
| Electrode fixation system | Screw (screw clamp), adaptable to different diameters |
| Electrode compatibility | Electrodes with shaft Ø 2.4 mm |
| Included electrode | Blade electrode (up to 20 autoclave cycles) |
| Sterilisation | Autoclave, up to 100 cycles (handle) |
| Protection | High insulation against liquids |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | II B |
| CND | Z12010980 |
| GMDN | 42552 |
| EAN | 8033003262665 |
4. Equivalences and Cross-References
No official equivalence table validated by the manufacturer has been found in reliable sources that cross-references reference 30539 with codes from other brands on a 1:1 interchangeable basis. However, its functional relationship with the following references from the reusable monopolar electrosurgery market has been verified against the manufacturer’s official catalogue and internal electrosurgery documentation:
| Manufacturer / Brand | Product / Family | Reference | Equivalence level | Observations |
|---|---|---|---|---|
| (Italy) | Autoclavable ORION PLUS handle, double push button, screw fixation, 3 m silicone cable and blade electrode | 30539 | Original reference (this product) | Code and attributes verified in the manufacturer’s official catalogue. |
| (Italy) | Sterile disposable straight blade electrode Ø 2.4 mm, 7 cm | 30671 | Compatible consumable | Replacement electrode compatible with Ø 2.4 mm shaft for handles such as the ORION PLUS. |
| FIAB / European line | Reusable double push button handle, Valleylab type connector, 320 cm cable | F4141 | Comparable by category (not interchangeable 1:1) | Differences: 30 sterilisation cycles versus 100; 320 cm cable versus 3 m; locking fixation versus screw. |
| Bovie / Aspen Surgical (USA) | Reusable push button pencil, 3-pin Valleylab type connection | ESPR2 | Comparable by category (not interchangeable 1:1) | Validated for up to 100 autoclave cycles; does not include electrode and its main market is North American. |
In all cases, each field must be checked —shaft diameter (Ø 2.4 mm), fixation system, connector type, authorised sterilisation cycles and regulatory classification— before any substitution. There is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before use in tendering.
5. Selection tips and variants of interest
Generator compatibility: the Valleylab type connection of this handle is compatible with most electrosurgical generators on the market (Covidien/Medtronic and similar). For equipment with other sockets (4 mm, 5 mm), consult the adapters in the electrosurgery range.
Electrode spares: always check the shaft diameter (Ø 2.4 mm) against the housing of your handle. To replace the included blade electrode, consider the sterile disposable electrodes Ref. 30671 (straight blade, 7 cm) or other tips from the compatible family.
Operating theatre maintenance: record the number of sterilisation cycles (handle up to 100, included electrode up to 20) and remove the handle at any sign of deterioration of the body, the push buttons or the cable. For institutional volumes, hospital supply agreements or validation of equivalents from other brands, contact the technical-commercial team of Cahnos:. For large orders you can request a quote.