Description
1. Commercial Introduction
The paediatric ECG electrodes (Ref. F9060P / BRLF9060P) are the ideal disposable consumable for obtaining electrocardiograms in paediatric patients. Their foam base and integrated conductive paste ensure comfortable fixation and a low-impedance skin-electrode contact, with optimal trace detection from the start of the recording. Presented in a practical pack of 50 units, they are the high-turnover solution for cardiology, paediatrics, emergency, diagnostic consultation and primary care services seeking reliability, hygiene and excellent cost per procedure.
2. Technical Explanation
A surface ECG electrode acts as an interface between the patient’s skin and the monitor or electrocardiograph: it captures the heart’s electrical activity and transmits it with the least possible distortion. In the paediatric population, recording quality depends especially on three factors: firm and comfortable adhesion (the electrode must remain fixed throughout the recording), low contact impedance (provided by the conductive paste) and good stability against patient movement.
The foam base is light and flexible: it protects the gel and the sensor, adapts to the contour of the child’s chest and maintains its integrity during the recording. The conductive paste ensures rapid and stable signal capture, optimising trace detection and reducing the need for repeats due to poor signal. Being a single-use and disposable product, hygiene is guaranteed and cross-contamination between patients is avoided.
3. Technical Specifications
Main features according to the manufacturer’s catalogue:
| Characteristic | Specification |
|---|---|
| Product type | ECG electrodes (E.C.G. electrodes) for paediatric patient (PED.) |
| Base / support | Foam material (foam) |
| Conductive gel | Conductive paste (conductive paste) |
| Trace detection | Optimal trace detection |
| Diameter | 43 mm |
| Presentation | Pack of 50 pieces (50 pcs) |
| Use | Single-use, disposable |
Available references:
| Reference | Origin | Description |
|---|---|---|
| F9060P | Manufacturer reference | Paediatric ECG electrodes, Ø 43 mm, pack of 50 units. |
| BRLF9060P | SKU Cahnos | Paediatric ECG electrodes, Ø 43 mm, pack of 50 units. |
Product data:
| Value | Value |
|---|---|
| Manufacturer | Boscarol |
| Target population | Paediatric |
| Commercialisation | (see conditions) |
4. Equivalences and Cross-References
The manufacturer’s catalogue does not include a validated equivalence table authorising the 1:1 substitution of this electrode with references from other brands. Within the Cahnos catalogue there are comparable paediatric electrodes by category (disposable foam ECG electrode with gel for the paediatric population), always pending field-by-field verification of diameter, gel type and connection before any substitution:
| Manufacturer / Brand | Indicative reference | Equivalence level | Observations |
|---|---|---|---|
| GIMA / FIAB (Italy) | GM33370 (FIAB code F9060P) | Comparable by category, not interchangeable 1:1 | Paediatric PE foam electrode with solid gel, Ø 40 mm, snap connection and presentation of 50 units, according to the GIMA catalogue. It differs in diameter (40 mm vs 43 mm) and gel type compared to the conductive paste of this reference. |
| GIMA / FIAB (Italy) | GM33371 (FIAB code F9060) | Comparable by category, not interchangeable 1:1 | Adult version of the same family: PE foam with solid gel, oval format of Ø 48 x 50 mm and snap connection. Verify diameter and application before substituting. |
| Top Trace (Ceracarta) – Cahnos | 0590016 (NM 30 RFI) | Comparable by category, not interchangeable 1:1 | Paediatric foam electrode of RFI type with Ø 30 mm and solid gel, documented in the Cahnos catalogue. Smaller diameter; verify measurements and connection. |
Any substitution must be validated against the manufacturer’s technical data sheet and the patient cable of the monitoring system, checking one by one the measurements, support, gel type and connector. Consult the technical-commercial department of Cahnos before use in tenders.
5. Selection tips and variants of interest
Select this electrode when you need a reliable paediatric consumable for electrocardiographic recording with rapid and stable signal capture thanks to its conductive paste and its 43 mm diameter. Before placing the order, verify the type of connector that the patient cable of your electrocardiograph or monitor accepts to ensure the correct fit.
Prepare the patient’s skin by cleaning and drying the application area (chest) and avoiding creams or oily residues to optimise contact impedance. Keep the packs closed in a dry, cool place, rotate stock on a FIFO basis and respect the expiry date indicated on the packaging, as the conductive paste may lose conductivity if the packaging is opened or deteriorates.
For complete paediatric service fittings, supply volumes or tenders, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connection of your cables. For large orders you can request a quote.