Description
1. Commercial Introduction
The bridge electrode for EEG and EMG made of silver/silver chloride (Ag/AgCl) in blue is the reusable electrode that your neurophysiology service needs to obtain clean, stable and reproducible electroencephalographic and electromyographic recordings. Manufactured with a silver/silver chloride (Ag/AgCl) sensor in adult size, it guarantees superior conductivity and faithful transmission of low-amplitude bioelectrical signals, reducing noise and artefacts in the recorded signal. Its presentation in an indivisible pack of 2 units facilitates replenishment in examination rooms, EEG laboratories, neurology consultations and electromyography units, at an excellent cost per electrode. It is a medical device with CE marking (class 1, MDR) intended for clinical and hospital use.
2. Technical explanation of the product and procedure
Electroencephalography (EEG) records cerebral electrical activity using electrodes placed on the scalp, usually distributed according to the international 10-20 system; electromyography (EMG) records muscular electrical activity. In both cases, the signals are of very low amplitude (microvolts), so the bridge electrode acts as a contact interface between the skin and the recording system: its silver/silver chloride (Ag/AgCl) sensor provides an electrode-skin interface with low polarisation potential and low noise, an essential feature for obtaining reliable, undistorted traces.
The bridge design allows the electrode-skin distance to be adjusted and maintains stable contact throughout the examination, even during prolonged recordings or with uncooperative patients, while the piece in biocompatible material provides patient comfort. The electrode is used with the conductive medium (EEG gel or cream) and with the connection leads suitable for the recording equipment, forming the standard clinical neurophysiology setup.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Type | Bridge electrode for EEG and EMG |
| Reference (SKU Cahnos) | 13088 |
| Sensor material | Silver / silver chloride (Ag/AgCl) |
| Colour | Blue |
| Size | Adult |
| Presentation | Indivisible pack of 2 units |
| Minimum sales unit | Pack of 2 units |
| Applications | Electroencephalography (EEG) and electromyography (EMG) |
| CE Class | 1st (MDR), according to the manufacturer’s official document |
| Use | Clinical and hospital use, especially in neurology and electromyography |
| Reusable | Yes (reusable clinical use, according to the manufacturer’s data sheet) |
| Manufacturer’s document | COD.-13088-13669-ELECTRODOS-DE-PUENTE |
The official technical data sheet for this reference is available in the manufacturer’s document COD.-13088-13669-ELECTRODOS-DE-PUENTE, which describes these electrodes as bridge electrodes for adults in silver/silver chloride, CE marking class 1. For tenders requiring the declaration of conformity or additional certificates, please request them from our technical-commercial department.
4. Equivalences and Cross-References
This electrode belongs to the category of bridge electrodes for EEG/EMG with a silver chloride sensor, adult size and adjustable bridge system. There is no manufacturer-validated equivalence table cross-referencing this reference with other systems; the alternatives from other manufacturers cited below have been checked against the respective manufacturer’s official catalogue and are classified as comparable by category, not interchangeable 1:1: they share clinical function, sensor material and adult size, but differ in bridge material, fixation/adjustment system, colour coding and pack size. Always verify these parameters in the manufacturer’s technical data sheet before substituting in a tender.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Spes Medica (Italy) | Bridge Electrodes EEG, Ag/AgCl electrode with connection pin, adult size | BEAG00A2 / BEAG00A7 (adult, Ag/AgCl, pack of 10 units) | Comparable by category (not interchangeable 1:1) | Bridge electrode for EEG with Ag/AgCl sensor in adult size and universal connector compatible with 2 mm spring pin and crocodile clip; ABS bridge with adjustment screw. Confirmed in the official Spes Medica catalogue (037_Catalogo-Spes-ENG). It differs in bridge material (ABS), screw adjustment system, its own colour coding and packaging (10 units vs pack of 2 units). |
| GVB-geliMED (Germany) | Sintered Ag/AgCl bridge electrode with silver pin, adult size | BESW000A2 | Comparable by category (not interchangeable 1:1) | Sintered Ag/AgCl bridge electrode for EEG in adult size, with a 10 mm recording surface, connector compatible with 2 mm and crocodile clip, red colour and CE class I. Confirmed on the official GVB-geliMED website. It differs in the sensor (sintered Ag/AgCl vs Ag/AgCl), the declared recording surface (10 mm), the colour and packaging (5 or 10 units vs pack of 2 units). |
There is no manufacturer-validated equivalence table; consult the technical department before use in a tender. Other brands marketing silver chloride bridge electrodes for EEG/EMG are Schröter, Deymed, Neuroline and Caesar Electrodos, whose specific reference codes could not be confirmed in public sources and are therefore not listed in this table. The references cited must be checked against the technical data sheet and official instructions for use of each manufacturer before any substitution.
5. Selection tips and variants of interest
Colour variant: within the same Cahnos family, this blue bridge electrode (ref. 13088) shares material, size and presentation with the red variant (ref. 13669); choose the colour that best suits the coding of your setups by patient or channel.
Stability in prolonged recordings: to keep bridge electrodes firmly placed during recording, combine them with the 2-strap silicone EEG cap (ref. GORROECG2) or the 4-strap one (ref. GORROECG4), which secure the electrodes according to the international 10-20 system without pressure points.
Conductive medium: apply a high-viscosity conductive gel or cream for EEG/EMG (refs. 18423 or 12941) to reduce contact impedance and optimise signal quality.
Compatibility: before formalising the order, confirm with our technical-commercial department the compatibility of this electrode’s connection and fixation system with the recording leads and equipment in your service, especially if you work with setups of more than 32 channels in adult size.
For institutional orders, supply contracts or compatibility queries in specifications and tenders, contact our technical-commercial team.





Reviews