Description
1. Commercial Introduction
The Premium neonatal cuff (ref. 32818) is the original high-quality replacement for dual-tube connection sphygmomanometers. Designed specifically for newborn patients and low-birth-weight infants, it ensures a firm fit, uniform pressure and reliable blood pressure readings in paediatrics, neonatology, outpatient clinics and home care settings. As a factory-made part, it preserves the inflation behaviour and compatibility required by your original device.
2. Technical explanation
The cuff is the component of the sphygmomanometer that is placed around the patient’s arm and, when inflated, temporarily occludes the brachial artery to allow non-invasive measurement of systolic and diastolic blood pressure. The internal bladder must distribute pressure evenly and maintain an airtight seal so that the device correctly detects the oscillations and provides reliable values.
This model from the Premium range incorporates a thermoplastic polyurethane (TPU) bladder, which distributes pressure evenly over the limb, wrapped in a high-quality 210D nylon casing with a quick-adjustment Velcro closure. The assembly has passed durability tests of up to 10,000 cycles. Its 2-tube configuration makes it compatible with dual-connection aneroid sphygmomanometers from the Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton families.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 32818 |
| Model / Size | Newborn (Neonate) |
| Cuff measurements | 5.5 x 18.5 cm |
| Arm circumference | 9.5 – 13.5 cm |
| Material | High-quality 210D nylon |
| Bladder (blister) | TPU (thermoplastic polyurethane) |
| Closure | Velcro |
| Colour | Dark grey (dark grey) |
| Tube configuration | 2 tubes |
| Durability | Tested up to 10,000 cycles |
| Compatibility | Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton… |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| GM32818 (Ref. 32818) | Premium neonatal cuff with TPU bladder, 2 tubes, 210D nylon, 5.5×18.5 cm | 1 pc |
Product data
| Sales unit | 1 pc |
|---|---|
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C99 |
| EAN | 8023279328189 |
4. Equivalences and Cross-References
This cuff corresponds to the manufacturer’s original premium replacement with reference 32818 (SKU Cahnos GM32818), verified in the Product_DB.csv catalogue. The manufacturer does not declare a 1:1 equivalence table with cuffs from other blood pressure monitor brands, as each manufacturer uses its own connectors and fitting sizes; any replacement must be confirmed beforehand by verifying the connection system (2 tubes), the fitting diameter and the device size.
The following related references are identified within the Premium range itself:
| Reference | Description | Related items |
|---|---|---|
| GM32817 (Ref. 32817) | Premium neonatal cuff with TPU bladder, 1 tube, 210D nylon, 5.5×18.5 cm | Same size with 1-tube configuration |
| GM32887 (Ref. 32887) | Premium infant (Infant) cuff with TPU bladder, 2 tubes, 7.5×26 cm, arm 13-19 cm | Larger size from the same 2-tube Premium line |
| GM32838 (Ref. 32838) | Premium thigh (Thigh) cuff with TPU bladder, 2 tubes, 82×21.5 cm | Extreme size from the same 2-tube Premium line |
5. Selection tips and variants of interest
Select the cuff size according to the patient’s actual arm circumference (measured at the midpoint between the shoulder and the elbow): this neonatal model covers 9.5 to 13.5 cm. An inappropriate cuff distorts measurements, so choosing the correct size is crucial in paediatric clinical practice.
Check compatibility: this model has 2 tubes and is designed for dual-connection aneroid sphygmomanometers (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton). If your blood pressure monitor has a single connection (1 tube, e.g. Sirio, London, Boston, Roma 1T, Tokyo, Madrid), you should choose the 1-tube configuration in the same size (ref. GM32817).
Maintenance: periodically inspect the condition of the Velcro, the TPU bladder and the connection fitting; replace the cuff if there are signs of wear, air leaks or loss of adhesion to maintain the reliability of measurements. For other sizes in the same Premium line (infant, paediatric, adult, thigh), consult our catalogue.




Reviews
There are no reviews yet.