We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

3-in-1 Lipid Profile Test Kit + 35 µL Capillary Tubes + Safety Lancets for MISSION® Cholesterol Meter | Ref. 23935 (Box of 5)

26,60 €

Kit of 3-in-1 lipid profile test for the MISSION® Cholesterol Meter analyser (ref. 23932 / GM23932): allows determination of total cholesterol, HDL and triglycerides from a capillary blood sample of only 35 µL. Each box includes 5 test devices together with 35 µL capillary tubes and safety lancets for a comfortable and safe puncture. IVD self-testing device, presentation in a box of 5 units. For large orders you can request a quote: request conditions from our technical-commercial team.

Sales unit: caja de 5
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM23935

Description

1. Introduction

The 3-in-1 lipid profile test kit (ref. 23935) is the reference consumable for the MISSION® Cholesterol Meter analyser (ref. 23932). Designed for pharmacies, clinics, clinical analysis centres and screening programmes, it provides a complete assessment of the patient’s lipid profile quickly, conveniently and with minimal invasiveness. Each box contains 5 test devices, 35 µL capillary tubes and safety lancets, so that sample collection and analysis can be carried out in a single workflow, without the need for venepuncture.

2. Technical explanation

The 3-in-1 test device is designed for use exclusively with the MISSION® Cholesterol Meter analyser, a reflectance photometry instrument that provides quantitative results in approximately 2 minutes and memory for 200 results with date and time. From a single 35 µL capillary blood sample (obtained using the capillary tube after puncture with a safety lancet), total cholesterol (CHOL), high-density lipoprotein (HDL) and triglycerides (TRIG) are determined. From these values, the analyser also calculates LDL, the CHOL/HDL ratio and cardiac risk assessment, with the option of expressing results in mg/dL or mmol/L. It is an IVD self-testing system, suitable for use both by healthcare professionals and in supervised self-testing programmes.

3. Technical Specifications

Product data

Parameter Specification
Manufacturer GIMA
Sales unit Box of 5 units (box of 5 pcs)
Device type IVD – Self-test (Self Test)
CND W0101060109
EAN 0682607611331

Kit contents

Component Quantity
3-in-1 lipid profile test devices 5
Capillary tubes (35 µL) Included
Safety lancets Included

Available references

Reference Description
23935 (GM23935) 3-in-1 lipid profile test + 35 µL capillary tubes + safety lancets – box of 5 units (this product)

Compatible system specifications (MISSION® 23932 analyser)

Parameter Specification
Detection principle Reflectance photometry
Test parameters CHOL, HDL and TRIG (with LDL, CHOL/HDL ratio and calculated cardiac risk assessment)
Sample volume 35 µL (3-in-1 lipid profile device)
Sample type Capillary blood
Time to result Approx. 2 minutes
Measurement ranges CHOL: 100-500 mg/dL; HDL: 15-100 mg/dL; TRIG: 45-650 mg/dL
Measurement units mg/dL or mmol/L

4. Equivalences and Cross-References

This kit is the consumable for the MISSION® Cholesterol Meter analyser, marketed as GM23932 (factory reference 23932). The format with safety lancets (ref. 23935, GM23935) shares the same test device and the same 35 µL capillary tubes as reference GM23933, although the latter is presented in a box of 25 units and does not include lancets. There is no official 1:1 equivalence table with test devices from other manufacturers; it is always recommended to verify the compatibility of the consumable with the analyser model before any substitution.

5. Selection tips and variants of interest

If you are starting to use the system or have a low test volume, the box of 5 units with safety lancets (GM23935) is the most suitable presentation, as it includes everything needed for sample collection. For services with a higher turnover of lipid profile tests, consider reference GM23933 (box of 25 units, without lancets) and complete the supply with safety lancets if your protocol requires it. This consumable must only be used with the MISSION® Cholesterol Meter analyser (GM23932), following the manufacturer’s instructions for the correct storage of the devices and the application of the sample. For volume orders, tender specifications or advice on the complete system, contact your technical-commercial advisor at Cahnos.

Additional information

Manufacturer reference

23935

Sales unit

Box of 5 units

Device type

IVD – Self-test (Self Test)

CND code

W0101060109

EAN

0682607611331

Contents

5 lipid profile 3-in-1 tests + 35 µL capillary tubes + safety lancets

Parameters

Total cholesterol (CHOL), HDL and triglycerides (TRIG)

Sample volume

35 µL

Sample type

Capillary blood

Compatibility

MISSION® Cholesterol Meter analyser (ref. 23932 / GM23932)

Presentation

Box of 5 units

Presentacion

Box of 5

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “3-in-1 Lipid Profile Test Kit + 35 µL Capillary Tubes + Safety Lancets for MISSION® Cholesterol Meter | Ref. 23935 (Box of 5)”

Your email address will not be published. Required fields are marked *