Description
1. Introduction
The 3-in-1 lipid profile test kit (ref. 23935) is the reference consumable for the MISSION® Cholesterol Meter analyser (ref. 23932). Designed for pharmacies, clinics, clinical analysis centres and screening programmes, it provides a complete assessment of the patient’s lipid profile quickly, conveniently and with minimal invasiveness. Each box contains 5 test devices, 35 µL capillary tubes and safety lancets, so that sample collection and analysis can be carried out in a single workflow, without the need for venepuncture.
2. Technical explanation
The 3-in-1 test device is designed for use exclusively with the MISSION® Cholesterol Meter analyser, a reflectance photometry instrument that provides quantitative results in approximately 2 minutes and memory for 200 results with date and time. From a single 35 µL capillary blood sample (obtained using the capillary tube after puncture with a safety lancet), total cholesterol (CHOL), high-density lipoprotein (HDL) and triglycerides (TRIG) are determined. From these values, the analyser also calculates LDL, the CHOL/HDL ratio and cardiac risk assessment, with the option of expressing results in mg/dL or mmol/L. It is an IVD self-testing system, suitable for use both by healthcare professionals and in supervised self-testing programmes.
3. Technical Specifications
Product data
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Sales unit | Box of 5 units (box of 5 pcs) |
| Device type | IVD – Self-test (Self Test) |
| CND | W0101060109 |
| EAN | 0682607611331 |
Kit contents
| Component | Quantity |
|---|---|
| 3-in-1 lipid profile test devices | 5 |
| Capillary tubes (35 µL) | Included |
| Safety lancets | Included |
Available references
| Reference | Description |
|---|---|
| 23935 (GM23935) | 3-in-1 lipid profile test + 35 µL capillary tubes + safety lancets – box of 5 units (this product) |
Compatible system specifications (MISSION® 23932 analyser)
| Parameter | Specification |
|---|---|
| Detection principle | Reflectance photometry |
| Test parameters | CHOL, HDL and TRIG (with LDL, CHOL/HDL ratio and calculated cardiac risk assessment) |
| Sample volume | 35 µL (3-in-1 lipid profile device) |
| Sample type | Capillary blood |
| Time to result | Approx. 2 minutes |
| Measurement ranges | CHOL: 100-500 mg/dL; HDL: 15-100 mg/dL; TRIG: 45-650 mg/dL |
| Measurement units | mg/dL or mmol/L |
4. Equivalences and Cross-References
This kit is the consumable for the MISSION® Cholesterol Meter analyser, marketed as GM23932 (factory reference 23932). The format with safety lancets (ref. 23935, GM23935) shares the same test device and the same 35 µL capillary tubes as reference GM23933, although the latter is presented in a box of 25 units and does not include lancets. There is no official 1:1 equivalence table with test devices from other manufacturers; it is always recommended to verify the compatibility of the consumable with the analyser model before any substitution.
5. Selection tips and variants of interest
If you are starting to use the system or have a low test volume, the box of 5 units with safety lancets (GM23935) is the most suitable presentation, as it includes everything needed for sample collection. For services with a higher turnover of lipid profile tests, consider reference GM23933 (box of 25 units, without lancets) and complete the supply with safety lancets if your protocol requires it. This consumable must only be used with the MISSION® Cholesterol Meter analyser (GM23932), following the manufacturer’s instructions for the correct storage of the devices and the application of the sample. For volume orders, tender specifications or advice on the complete system, contact your technical-commercial advisor at Cahnos.