Description
1. Commercial Introduction
The 3-in-1 lipid profile test (ref. 23933) is the consumable designed for the MISSION® Cholesterol Meter analyser (ref. 23932), the ideal solution for obtaining a complete assessment of the patient’s lipid profile quickly, conveniently and minimally invasively. Each box includes 25 test devices together with the 35 µL capillary tubes needed for sample collection, so the analysis can be performed at the point of care without the need for venepuncture. Designed for pharmacies, medical practices, clinical analysis centres, prevention services and cardiovascular risk screening programmes.
2. Technical explanation of the procedure
Each 3-in-1 test device is designed for exclusive use with the MISSION® Cholesterol Meter analyser, a reflectance photometry device that provides quantitative results in approximately 2 minutes and memory for 200 results with date and time. With a single 35 µL capillary blood sample, obtained using the included capillary tube after the puncture, total cholesterol (CHOL), high-density lipoprotein (HDL) and triglycerides (TRIG) are determined. From these values, the analyser also calculates LDL, the CHOL/HDL ratio and cardiac risk assessment, with the option of expressing results in mg/dL or mmol/L. It is an IVD self-monitoring system, suitable for both healthcare personnel and supervised self-test programmes.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 23933 |
| SKU Cahnos | GM23933 |
| Sales unit | Box of 25 units (box of 25 pcs) |
| Device type | IVD – Self-test (Self Test) |
| CND | W0101060109 |
| EAN | 0682607611027 |
Box contents
| Component | Quantity |
|---|---|
| 3-in-1 lipid profile test devices | 25 |
| 35 µL capillary tubes | Included |
Specifications of the compatible system (MISSION® Cholesterol Meter analyser, ref. 23932)
| Parameter | Specification |
|---|---|
| Detection principle | Reflectance photometry |
| Test parameters | CHOL, HDL and TRIG (with LDL, CHOL/HDL ratio and calculated cardiac risk assessment) |
| Sample volume | 35 µL (3-in-1 lipid profile device) |
| Sample type | Capillary blood |
| Time to result | Approx. 2 minutes |
| Measurement ranges | CHOL: 100-500 mg/dL; HDL: 15-100 mg/dL; TRIG: 45-650 mg/dL |
| Measurement units | mg/dL or mmol/L |
4. Equivalences and Cross-References
This product corresponds to reference 23933, supplied by Cahnos under SKU GM23933. It is the specific consumable for the MISSION® Cholesterol Meter analyser (ref. 23932, SKU GM23932) and shares the test device and 35 µL capillary tubes with the kit of reference 23935 (SKU GM23935), which is presented in a box of 5 units and also includes safety lancets. No 1:1 equivalence table with test devices from other manufacturers has been documented in reliable sources, since the physical-optical compatibility is specific to this platform; any comparison in tenders or substitution must be validated field by field with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
This reference (GM23933, box of 25 units) is the appropriate presentation for services with medium-high turnover of lipid profile tests. To start using the system or for low test volumes, the GM23935 kit (box of 5 units with safety lancets included) is the most practical option, as it includes everything needed for sample collection. The consumable must only be used with the MISSION® Cholesterol Meter analyser (GM23932) and can be complemented with the MISSION® thermal printer (ref. 23929) for immediate printing of results. It is recommended to follow the manufacturer’s instructions for the correct storage of the devices and the application of the sample, as well as to validate the batch with the system’s control devices. For large orders you can request a quote: consult our technical-commercial team for conditions, volumes and supply times.