Multiparameter vital signs monitor Compact 7 (PROVIEW 12): 12.1″ touchscreen for ICU with 3/5/6/12-lead ECG, 8 parameters, detection of 27 arrhythmias, EWS and Glasgow Coma Scale

2.338,20 €

The Compact 7 (PROVIEW 12) bedside multiparameter monitor is the complete solution for ICU, emergency and resuscitation: 12.1″ capacitive touchscreen (800 × 600 pixels) with up to 7 simultaneous waveforms and monitoring of 3/5/6/12-lead ECG, SpO2, NIBP, respiration, dual-channel temperature and, via optional modules, IBP, cardiac output (C.O.) and EtCO2 in adult, pediatric and neonatal patients. It detects 27 types of arrhythmias and incorporates Early Warning Score (EWS) and Glasgow Coma Scale (GCS). It includes integrated thermal printer, Li-ion battery up to 4 h (8 h option), 180 h of trends and LAN/USB connectivity for monitoring central station, with accessory set ready to use.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
40.20-5370

Description

1. Advanced monitoring for intensive care

The Compact 7 Monitor (model PROVIEW 12) is a high-precision bedside multiparameter monitor designed for intensive care units (ICU), emergency, resuscitation and intermediate care. Its 12.1″ capacitive touchscreen provides a sharp image and very intuitive gesture control, with up to 7 waveforms visible simultaneously. With compact dimensions of 175 x 320 x 262 mm and an approximate weight of 4 kg, it includes an integrated carrying handle and accessory drawer, and is delivered with the complete accessory set to start monitoring from day one.

2. Technical explanation of the equipment

The Compact 7 measures up to 8 parameters: ECG with 3/5/6/12 leads, pulse oximetry (SpO2), oscillometric non-invasive blood pressure (NIBP) in manual, automatic and STAT modes, impedance respiration, dual-channel temperature (T1, T2 and TD with YSI 400 series probes) and, via optional modules, invasive blood pressure (IBP), cardiac output (C.O.) and EtCO2 capnography in MicroFlow or Mainstream version. The analysis algorithm identifies 27 types of arrhythmias, while the EWS (Early Warning Score) and Glasgow Coma Scale (GCS) tools help to detect early patient deterioration and assess their level of consciousness. The 3-level prioritised alarm system, 180-hour trend recording and lithium-ion battery of up to 4 hours (8-hour option) ensure continuous and reliable monitoring. Compliant with UNE-EN/IEC 60601-1 and 60601-1-2.

3. Technical Specifications

Data verified against the manufacturer’s official technical data sheet (factory reference 20.20-5370):

Parameter Specification
Set type Bedside multiparameter monitor for intensive care
Display 12.1″ colour TFT capacitive touch (800 x 600 pixels)
Waveforms Up to 7 simultaneous (ECG, SpO2, respiration, CO2, IBP)
Dimensions 175 x 320 x 262 mm (W x H x D)
Weight Approx. 4 kg
Power supply 100-240 V AC (±10 %), 50/60 Hz, 100 VA
Battery Rechargeable Li-ion 11.1 V, 2.5 Ah (up to 4 h); optional 5.0 Ah (up to 8 h)
Patient population Adult, paediatric and neonatal
Regulatory standard UNE-EN/IEC 60601-1 and 60601-1-2 (electromedical equipment)
Interface languages Spanish, English, German, French, Italian, Portuguese, Russian, Czech, Polish, Hungarian, Romanian, Turkish and others
ECG and cardiac analysis Specification
Leads 3 (I, II, III), 5 (I, II, III, aVR, aVL, aVF, Vx), 6 and 12 (V1-V6); automatic lead switching
Heart rate Adult 10-300 bpm; paediatric/neonatal 10-350 bpm; accuracy ±1 bpm or ±1 %
Arrhythmia analysis 27 types (ventricular tachycardia, ventricular fibrillation, asystole, etc.)
ST segment Range -2.0 to +2.0 mV; resolution 0.01 mV
CMRR ≥ 110 dB in monitoring mode; ≥ 100 dB in diagnostic mode
Sweep speed 6.25 / 12.5 / 25 / 50 mm/s
Physiological parameters Specification
Respiration 0-150 rpm; accuracy ±2 rpm or ±2%; adjustable apnoea alarm delay 10-60 s
NIBP (PANI) Oscillometric; manual, automatic and STAT modes; automatic intervals from 1 min to 8 h; STAT cycle 5 min
NIBP ranges Adult: SYS 30-270 / DIA 10-220 / MEAN 20-235 mmHg. Paediatric: 30-235 / 10-220 / 20-235 mmHg. Neonatal: 30-135 / 10-110 / 20-125 mmHg
NIBP accuracy ±3 mmHg (static); ±5 mmHg mean clinical error; standard deviation ≤ 8 mmHg
SpO2 0-100%; accuracy 70-100% ≤ 3% (including probe); pulse 25-300 bpm ±3 bpm; perfusion index 0.05-20%
Temperature T1, T2 and TD; YSI 400 series probe (2252 Ω at 25 °C); range 0.0-50.0 °C; accuracy ±0.1 °C
Options, storage and connectivity Specification
IBP (optional) Range 50-360 mmHg; transducer 5 µV/V/mmHg; sites ART, CVP, ICP, PA, Ao, UAP, BAP, FAP, LAP, RAP, PAWP, P1/P2
EtCO2 (optional) MicroFlow: 0-25% (0-190 mmHg), sample flow 50 ± 10 ml/min, warm-up < 10 s, rise time < 3 s; Mainstream with rise time < 90 ms; awRR 0-150 rpm ±1 rpm
Cardiac output C.O. (optional) 0.1-20 l/min; blood temperature TB 23-43 °C; injectate temperature TI -0.1 to 27 °C
Drip monitor DM (optional) 5-200 drops/min; alarm and stop when infusion is complete
Storage Trends 180 h; alarms 3,000 groups; NIBP 2,400 groups; waveforms 72 h; arrhythmia events 3,000
Connectivity RJ45 (LAN), 2 USB ports, VGA (optional), multifunction connector (nurse call, defibrillator synchronisation and analogue output), WiFi 2.4/5G (optional); monitoring central station for up to 66 devices (optional)
Printer Integrated thermal printer; speeds 12.5 / 25 / 50 mm/s; 50 mm paper

4. Equivalences and Cross-References

The same device is marketed in other markets under the factory reference 20.20-5370 (also documented as NI-20.20-5370), to which this technical data sheet corresponds. There is no official equivalence table validated by the manufacturer that cross-references this reference with models from other brands; the alternatives listed below are comparable by category (12.1″ bedside multiparameter monitor for ICU) but not 1:1 interchangeable, so they must be compared field by field (ECG leads, included parameters, EWS/GCS, battery and accessories) before adoption.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Mindray UMEC Series uMEC 12 Comparable by category (not interchangeable 1:1) 12.1″ LED touchscreen (800 x 600), ECG 3/5/12 leads, up to 8 waveforms, SpO2, NIBP, respiration and temperature; optional IBP, CO2 and cardiac output; Li-ion battery up to 4 h. Does not include EWS or GCS as standard. Confirmed in official manufacturer documentation and authorised distribution.
Comen C80 Series C80 Comparable by category (not interchangeable 1:1) 12.1″ touchscreen; standard configuration ECG, respiration, SpO2, NIBP, PR and 1 temperature; optional 2nd temperature, 2 IBP, EtCO2, cardiac output, ICG and thermal printer. Confirmed in the manufacturer’s official technical data sheet.
Edan X Series X12 Comparable by category (not interchangeable 1:1) 12.1″ TFT touchscreen (800 x 600) with up to 13 waveforms; ECG up to 12 leads with automatic chest lead identification, RESP, NIBP, SpO2 and temperature; optional IBP; advanced arrhythmia and ST segment analysis. Without EWS or GCS as standard. Confirmed in the manufacturer’s official technical data sheet.
Contec CMS Series CMS9000 Comparable by category (not interchangeable 1:1) 12.1″ TFT screen; monitors ECG, RESP, SpO2, PR, NIBP and dual-channel temperature; optional 2 IBP, EtCO2 and thermal printer; suitable for adults, paediatric and neonatal patients; weight under 3 kg. Does not include EWS or GCS. Confirmed in the manufacturer’s catalogue and documentation.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

Define the clinical configuration: starting from the standard configuration (ECG, SpO2, NIBP, respiration and temperature), it can be expanded with IBP, cardiac output (C.O.), EtCO2 capnography (MicroFlow or Mainstream), drip monitor, high-capacity battery 5.0 Ah (8 h), WiFi module, VGA output and mounting accessories (trolley, wall bracket or column clamp). If your department uses centralised monitoring, consider the central station for up to 66 devices over wired or wireless network.

Within the Cahnos catalogue, the same family offers interesting variants: the 10.4″ screen model (SKU 40.20-5360, PROVIEW 10) for compact hospitalisation and observation stations, and the Compact 7 configurations with LAN/WLAN connectivity and HL7 compatibility (SKU 20.11-5900S and 20.11-6000S) for integration with hospital information systems. For public tenders, request the official technical data sheet (factory reference 20.20-5370) and always indicate the SKU 40.20-5370 and the desired modules. For maintenance, common consumables are available such as 50 mm thermal paper, disposable electrodes, NIBP cuffs in various sizes, SpO2 probes for adult/pediatric/neonatal, YSI 400 temperature probes and EtCO2 sampling lines; contact our technical-commercial department to guarantee the exact compatibility of each accessory.

Additional information

Model

PROVIEW 12 (marketed by Cahnos as Compact 7)

Display

12.1" colour TFT capacitive touch (800 x 600 pixels)

Waveforms

Up to 7 simultaneous (ECG, SpO2, respiration, CO2, IBP)

Parameters

ECG (3/5/6/12 leads), SpO2, NIBP, respiration, temperature (T1/T2/TD), IBP, cardiac output (C.O.) and EtCO2 (optional)

Early warning

EWS (Early Warning Score)

Coma scale

Glasgow Coma Scale (GCS)

Heart rate range

Adult 10-300 bpm; paediatric/neonatal 10-350 bpm; accuracy ±1 bpm or ±1 %

SpO2

0-100 %; accuracy 70-100 % ≤ 3 %; pulse 25-300 bpm ±3 bpm; PI 0.05-20 %

EtCO2

MicroFlow 0-25 % (0-190 mmHg), flow 50 ± 10 ml/min; optional Mainstream

Temperature

Dual channel T1, T2 and TD; YSI 400 series probe; 0.0-50.0 °C; ±0.1 °C

IBP

Range 50-360 mmHg; ART, CVP, ICP, PA, Ao, PAWP, P1/P2, etc.

Cardiac output

C.O. 0.1-20 l/min (optional)

Storage

Trends 180 h; 3,000 alarms; 2,400 NIBP groups; waveforms 72 h; 3,000 arrhythmias

Battery

Li-ion 11.1 V, 2.5 Ah (≈4 h); optional 5.0 Ah (≈8 h)

Power supply

100-240 V AC (±10 %), 50/60 Hz, 100 VA

Printer

Integrated thermal; 12.5 / 25 / 50 mm/s; 50 mm paper

Connectivity

RJ45 (LAN), 2 USB, optional VGA, multifunction connector, optional WiFi 2.4/5G; central station up to 66 units

Dimensions

175 x 320 x 262 mm (W x H x D)

Weight

Approx. 4 kg

Regulatory standard

UNE-EN/IEC 60601-1 and 60601-1-2

Manufacturer reference

20.20-5370 (PROVIEW 12)

Languages

Spanish, English, German, French, Italian, Portuguese, Russian, Czech, Polish, Hungarian, Romanian, Turkish and others

Included accessories

5-lead ECG cable, reusable adult SpO2 probe, NIBP cuff and tubing, electrodes and thermal printer

Warranty

24 months

Reference

40.20-5370

Product type

Multiparameter vital signs monitor for intensive care

Simultaneous waveforms

Up to 7 (ECG, SpO2, respiration, CO2, IBP)

ECG

3, 5, 6 and 12 leads with automatic switching

Arrhythmia analysis

27 arrhythmia types; S-T segment; CMRR ≥ 110 dB (monitoring)

Heart rate

Adult 10-300 bpm; paediatric/neonatal 10-350 bpm; ±1 bpm or ±1 %

Respiration

0-150 rpm; adjustable apnoea alarm 10-60 s

NIBP

Oscillometric; manual, auto and STAT modes; accuracy ±3 mmHg; adult/paediatric/neonatal ranges

Optional IBP

Range 50-360 mmHg; transducer 5 µV/V/mmHg; sites ART, CVP, ICP, PA, Ao, UAP, BAP, FAP, LAP, RAP, PAWP, P1/P2

Optional EtCO2

MicroFlow (0-25 %, flow 50 ± 10 ml/min) or Mainstream (rise time < 90 ms)

Optional cardiac output

0.1-20 l/min; TB 23-43 °C; TI -0.1 to 27 °C

Patient groups

Adult, paediatric and neonatal

Advanced functions

EWS (Early Warning Score), Glasgow Coma Scale (GCS)

Application

ICU, emergency, resuscitation and intermediate care

Tipo paciente

Adult, Neonatal, Paediatric