We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Finger pulse oximeter PULOX PO-200 (Ref. 713) | Portable SpO2 and heart rate monitor – Class IIa (CE MDD 93/42/CEE)

20,62 €

Finger pulse oximeter PULOX PO-200, portable and non-invasive monitor for spot measurement of oxygen saturation (SpO2) and heart rate. Dual-colour OLED display with pulse intensity bar, automatic shutdown after 5 seconds without signal and approximate battery life of 30 hours with two AAA batteries. SpO2 range 35–100% (±2% between 70–100%) and pulse 30–240 ppm, according to the manufacturer’s official manual. Ultra-lightweight (approx. 50 g), classified as a Class IIa medical device (MDD 93/42/CEE, Annex IX, Rule 10). Includes nylon bag, rubber case, 2 AAA batteries, neck cord and user manual. Ideal for consultation, primary care, home use and sports medicine.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
713

Description

1. PULOX PO-200 Finger Pulse Oximeter: fast, accurate and non-invasive SpO2 and pulse check

The PULOX PO-200 finger pulse oximeter (ref. 713) is a portable medical device designed to check non-invasively in seconds the arterial haemoglobin oxygen saturation (SpO2) and heart rate in adult and paediatric patients (15–110 kg). Its ultra-light forceps format — barely 50 g with batteries — makes it suitable for continued use in medical practices, primary care, home care, sports physiotherapy and personal health monitoring.

It is supplied ready to use with its nylon bag, rubber case, neck cord and two AAA alkaline batteries, with CE marking as a Class IIa device under Directive 93/42/EEC (MDD), Annex IX, Rule 10 and backed by the 24-month warranty from Cahnos. A simple, economical and reliable spot-screening solution for monitoring arterial oxygenation.

2. How it works: optical pulse oximetry technology

Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin. The PO-200 sensor emits light at two wavelengths —red 660 nm and infrared 940 nm— through the nail bed; a photodetector on the opposite side of the finger quantifies the light absorbed by the tissues. The pulsatile component of the signal, generated by the arterial beat, allows the percentage of saturated haemoglobin (SpO2) and heart rate to be calculated.

The dual-colour OLED screen simultaneously displays the SpO2 value, heart rate and the pulse intensity bar graph, and supports six reading orientations with adjustable brightness, making it easy to view for both the professional and the patient. The device incorporates automatic switch-off after 5 seconds without a detectable signal, a low-battery indicator on screen and a consumption of less than 30 mA, with an approximate battery life of 30 hours with two AAA batteries. It is designed for spot-check measurements, not for continuous patient monitoring.

3. Technical Specifications

The following values are taken from the official manufacturer user manual (PULOX PO-200):

Parameter Value
Model / factory designation PULOX PO-200 (designed by Novidion GmbH, Cologne; official manual)
Management reference 713 (SKU Cahnos)
Set type Finger pulse oximeter for spot-check measurement
Display Dual-colour OLED: SpO2, heart rate, pulse intensity bar and battery; 6 orientations and adjustable brightness
SpO2 measurement range 35 – 100 % (resolution 1 %)
SpO2 accuracy ±2 digits between 70 – 100 %; below 70 % unspecified
Heart rate range 30 – 240 bpm (resolution 1 bpm)
Heart rate accuracy ±2 bpm or ±2 % (whichever is greater)
Low perfusion measurement Yes, down to pulse saturation ≈ 0.4 % (SpO2 accuracy ±4 %)
Sensor wavelengths Red 660 nm / Infrared 940 nm
Power supply 2 AAA alkaline batteries 1.5 V (range 2.6 – 3.6 V)
Consumption / battery life ≤ 30 mA / approx. 30 hours of continuous use
Auto power-off Yes, after 5 seconds without detecting finger signal
Dimensions 57 × 31 × 32 mm (length × width × height)
Weight Approx. 50 g with batteries
Protection IP22
Operating temperature 10 °C – 40 °C (humidity 35 – 75 %)
Classification Medical device Class IIa (MDD 93/42/EEC, Annex IX, Rule 10)
Warranty 24 months

Box contents

Accessory Description
1 nylon bag Safe transport of the device
1 rubber case Additional protection against bumps and drops
2 AAA alkaline batteries Immediate power supply for the device
1 neck cord Holding and carrying during use
1 user manual Instructions for use, safety and maintenance

4. Equivalences and Cross-References

The PULOX PO-200 is marketed under the management reference 713 from Cahnos; its factory designation is PO-200 (official documentation of the PULOX family). There is no official equivalence table published by the manufacturer that cross-references this model with specific codes from other brands; the following comparisons have been verified field by field (screen type, measurement ranges, accuracy, power supply, dimensions and intended use) against technical data sheets and official documentation from each manufacturer:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
AEROCARE A310 (finger pulse oximeter) TA-9201310 (official AEROCARE catalogue / ref. ISSO) Comparable by category (not interchangeable 1:1) OLED screen with plethysmographic waveform and reading adjustment; SpO2 35–100% and pulse 30–250 bpm; consumption less than 30 mA and operation in low perfusion (≤0.3%). Pulse ranges different from those of the PO-200 (30–240 bpm).
Creative Medical (Shenzhen Creative Industry) PC-60B1 (finger pulse oximeter) PC-60B1 (official manufacturer’s brochure) Comparable by category (not interchangeable 1:1) OLED screen with SpO2, pulse, perfusion index (PI), pulse bar and waveform; SpO2 35–100%, pulse 30–240 bpm; 58.5 × 33.5 × 30 mm and 47 g. Includes perfusion index (PI), which the PO-200 does not have.
Nonin Medical Onyx Vantage 9590 9590 / N-9590 (verified on the manufacturer’s website and GUDID 00849686072785) Comparable by category (not interchangeable 1:1) Higher professional range: SpO2 0–100% and pulse 18–321 bpm, PureSAT® technology and automatic power-on; 60 g with 2 AAA batteries and published clinical validity. Measurement range and price much higher than those of the PO-200.

There is no equivalence table validated by the manufacturer that cross-references this reference with specific codes from other brands; the above references are functional category comparisons verified against official documentation and should not be treated as 1:1 substitutes without first validating specifications, certifications and tender documents. Consult the technical department of Cahnos before using this reference in public tenders.

5. Selection tips and variants of interest

  • Intended use: the PO-200 is designed for spot measurements (rapid screening) in the practice, at home, in emergency care and for sports monitoring; it is not suitable for continuous patient surveillance. For continuous monitoring, consider a handheld monitor with a reusable catheter, such as the PalmCare Pro (ref. 40.50-2240 and 40.50-2300), with trend memory, perfusion index and adjustable alarms.
  • No alarm function: if your service needs SpO2 or pulse warning limits, consider models in the same category with built-in alarm (e.g. the ME10 finger pulse oximeter, ref. 40.22-5205, with 6 display modes).
  • Catalogue variants: within the Cahnos finger pulse oximeter family you will find the ME5 (ref. 40.22-5206, large LED screen), the ME7 (ref. 40.21-5207, colour OLED with plethysmographic waveform) and the ME10 (ref. 40.22-5205, with alarm), as mid-to-professional range alternatives if you have a larger budget.
  • Batteries and maintenance: use quality AAA alkaline batteries, respect polarity, replace the batteries as soon as the low-battery warning appears and remove them if the device is to remain unused for a long time. Clean the device with a cloth slightly dampened with alcohol; do not immerse it in liquids or sterilise it with high-pressure steam.
  • Hygiene between patients: clean the sensor pads between uses and keep the device in its rubber case and nylon bag to avoid damage and extend its service life.

Additional information

Model

PULOX PO-200 (PULOX family, pulox.de)

Manufacturer reference

PO-200 (official manufacturer manual)

Set type

Finger pulse oximeter for spot-check measurement

Display

Dual-colour OLED: SpO2, heart rate, pulse intensity bar and battery; 6 orientations and adjustable brightness

SpO2 range

35 – 100 % (resolution 1 %)

Spo2 accuracy

±2 digits (70 – 100 %); below 70 % unspecified

Heart rate range

30 – 240 bpm (resolution 1 bpm)

Heart rate accuracy

±2 bpm or ±2 % (whichever is greater)

Low perfusion measurement

Yes, down to pulse saturation ≈ 0.4 % (SpO2 accuracy ±4 %)

Wavelengths

Red 660 nm / Infrared 940 nm

Power supply

2 AAA alkaline batteries 1.5 V (range 2.6 – 3.6 V)

Consumption

≤ 30 mA

Battery life

Approx. 30 hours of continuous use

Auto power-off

Yes, after 5 seconds without detecting finger signal

Dimensions

57 × 31 × 32 mm

Weight

Approx. 50 g with batteries

Protection

IP22

Operating temperature

10 °C – 40 °C (humidity 35 – 75 %)

Classification

Medical device Class IIa (MDD 93/42/EEC, Annex IX, Rule 10)

Population

Adult and paediatric patients from 15 to 110 kg

Included accessories

Nylon bag, rubber case, 2 AAA batteries, neck cord and user manual

Warranty

24 months

Reviews

There are no reviews yet.

Be the first to review “Finger pulse oximeter PULOX PO-200 (Ref. 713) | Portable SpO2 and heart rate monitor – Class IIa (CE MDD 93/42/CEE)”

Your email address will not be published. Required fields are marked *