Description
1. Commercial Introduction
Complete or renew the stock of your monitoring fleet with the reusable paediatric SpO2 pulse oximeter catheter (Ref. 33731). It is the replacement finger sensor intended for continuous, non-invasive monitoring of paediatric patients from 15 to 45 kg, compatible with the vital signs monitors BIONET BM1, BM3, BM5 and BM7. Being a reusable sensor, it offers a lower cost per patient than disposable catheters, simplifies the management of spare parts for the service and ensures continuity of care when the original sensor deteriorates or when a backup unit is desired to allow rotation between patients. Manufactured and distributed by Cahnos; our technical-commercial department will advise you on B2B terms, availability and delivery times. For large orders you can request a quote.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry. The catheter emits light at two wavelengths (red and infrared) through the patient’s vascular bed and a photodetector quantifies the differential absorption of light according to the degree of blood oxygenation, transmitting the signal to the monitor, which processes and displays the values in real time.
This paediatric finger catheter is sized for the weight range of 15 to 45 kg, with a head adapted to the child’s anatomy that ensures correct sensor contact and reduces motion artefacts during intermittent or continuous monitoring. As it is a reusable model, it must be cleaned and disinfected between patients following the manufacturer’s instructions and the centre’s protocol, and the condition of the cable and the contact area must be checked periodically to ensure signal quality. Important: for use with the indicated monitors, the extension cable Ref. 33716 (not included) is required, which interconnects the catheter with the equipment.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 33731 |
| SKU Cahnos | GM33731 |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| EAN | 8809276946355 |
Catheter features
| Parameter | Specification |
|---|---|
| Sensor type | Reusable paediatric SpO2 pulse oximetry catheter (finger sensor) |
| Patient population | Paediatric, 15-45 kg |
| Use | Reusable |
| Measured parameters | Blood oxygen saturation (SpO2) and pulse rate |
| Application | Non-invasive monitoring in paediatrics, outpatient clinics, emergency departments and hospitalisation |
| Compatibility | Vital signs monitors BIONET BM1, BM3, BM5 and BM7 |
| Required accessory | Extension cable Ref. 33716 (not included) |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| 33731 | Reusable paediatric SpO2 pulse oximeter catheter 15-45 kg for BIONET BM1, BM3, BM5 and BM7 monitors (this item) | 1 pc |
| 33716 | 2 m SpO2 extension cable with large 7-pin connector (required for connection to the monitors; not included) | 1 pc |
4. Equivalences and Cross-References
Ref. 33731 is the original code for this reusable paediatric SpO2 catheter, specifically indicated for the vital signs monitors BIONET BM1, BM3, BM5 and BM7. No 1:1 equivalence table validated by the manufacturer has been found in reliable sources that authorises the replacement of this catheter with sensors from other manufacturers (Nonin, Masimo, Nellcor, etc.), since compatibility depends on the type of connector and the electronic protocol of each device. In the event of any replacement in tenders or equipment fleets, always verify the exact make and model of your monitor with the technical-commercial department of Cahnos.
Within the family of reusable paediatric catheters themselves, there are other references of equivalent nature, such as Ref. 34347, as well as reusable paediatric catheters for other pulse oximeters from the same manufacturer (refs. 35054, 35106, 35215 and 35097). These catheters share category and target population, but are not interchangeable with each other without verifying the connector and the model of the device. The extension cable Ref. 33716 is the complementary accessory for this catheter, necessary for its operation with the indicated BIONET monitors.
5. Selection tips and variants of interest
Always verify the exact model of your monitor before placing the order: Ref. 33731 is the one indicated for the vital signs monitors BIONET BM1, BM3, BM5 and BM7. Remember that this catheter requires the extension cable Ref. 33716 (not included) for connection to the equipment; order it together with the catheter if you do not have it in your fleet.
Select the catheter according to the patient’s weight range: this model covers the paediatric population from 15 to 45 kg. In the Cahnos catalogue you will find other catheters from the same family for different populations and equipment, such as the reusable adult SpO2 catheter (Ref. 32903), the reusable paediatric catheter for Oxy series pulse oximeters (Refs. Ref. 35215 or 35106) and the replacement adult catheter for PC-300 (Ref. 35165).
As it is a reusable sensor, establish a cleaning and disinfection protocol between patients in accordance with the manufacturer’s instructions and periodically check the cable and the contact area to avoid erroneous readings. It is recommended to have at least one spare unit for each monitor in use to minimise downtime. Contact the technical-commercial team of Cahnos for B2B terms, supply contracts and volume orders.





Reviews