Description
1. Reusable neonatal probe for reliable monitoring
The neonatal SpO2 pulse oximeter probe (reference 35099) is the ideal replacement accessory for the Ref. 35095 monitor: a reusable probe with a Y-type design, specifically conceived for newborn infants, which enables continuous, non-invasive monitoring of blood oxygen saturation (SpO2) and pulse rate in the most vulnerable patient.
Its reusable construction makes it an economical and sustainable option for departments with a high patient turnover, as it can be used for extended periods with proper cleaning and disinfection between patients, following the manufacturer’s instructions for use.
2. Technical explanation
Pulse oximetry measures the functional oxygen saturation of arterial haemoglobin by spectrophotometry: the probe emits red and infrared light through the neonatal vascular bed and detects differential absorption according to the degree of blood oxygenation, calculating the SpO2 value and pulse rate from that signal.
The Y-type or clip design adapts the sensor to the newborn’s measurement site (usually the foot or hand), ensuring a stable fit and a quality plethysmographic signal even in low-weight patients. As a reusable probe, it connects directly to the patient cable of the Ref. 35095 monitor, making it easy to replace the sensor without having to change the equipment wiring.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer reference | 35099 |
| Catheter type | Reusable pulse oximeter (SpO2) probe, Y-type design |
| Patient population | Neonatal |
| Compatibility | Monitor Ref. 35095 |
| Sales unit | 1 pc |
| Manufacturer | GIMA |
| Device type | Medical device (medical device) |
| Device class | II A |
| CND | C900301 |
| GMDN | 36087 |
| EAN | 8023279350999 |
Data verified against the manufacturer’s catalogue (reference 35099).
4. Equivalences and Cross-References
Reference 35099 is the manufacturer’s own code for this reusable neonatal Y-type SpO2 probe. We do not have an official equivalence table validated by the manufacturer that cross-references this code with sensors from other brands on a 1:1 interchangeable basis. Before replacing any pulse oximeter probe in your monitor fleet, always verify the compatibility of the connector and communication protocol with the exact make and model of your equipment; our technical-commercial department can help you confirm the suitability of this probe for your monitor.
5. Selection tips and variants of interest
This probe is the recommended replacement for the Ref. 35095 monitor in care areas that treat newborn infants: neonatal intensive care units (NICU), maternity, delivery room and paediatrics. As it is a reusable accessory, plan rotation and maintenance following the manufacturer’s instructions to ensure measurement accuracy for each patient.
If your department also has monitors with a different technology or connector (for example, 9-pin Nellcor systems), check the Cahnos catalogue for the disposable probes compatible with that standard. For institutional orders, supply contracts or accessory standardisation needs, contact the Cahnos technical-commercial department: we will advise you on configuring the right replacement for each device.





Reviews
There are no reviews yet.