Description
1. Commercial Introduction
The digital clinical thermometer with flexible tip from Cahnos (ref. 0658999) is the most comfortable and safe option for routine body temperature monitoring at home, paediatric consultations, health centres and healthcare settings. Its flexible tip adapts to the patient’s anatomy and reduces discomfort during measurement, making it especially recommended for children, the elderly and uncooperative patients. Mercury-free, with a clear digital reading and audible end-of-measurement signal, it is a class IIa medical device with CE marking, ready to use from the first measurement as it includes battery, protective case and instruction manual.
2. Technical explanation of the equipment
The thermometer uses an electronic thermal sensor located in the flexible tip that reaches temperature equilibrium with the patient’s body after about 60 seconds in oral use. The display shows the value with a resolution of 0.1 °C: if the temperature is below 32.0 °C, the indicator «L °C» appears, and if it exceeds 43.0 °C, «H °C» appears, avoiding erroneous out-of-range readings. When the measurement is complete, the device emits 10 long beeps and, if the temperature is equal to or higher than 37.8 °C, 30 short beeps sound as a fever alert. It incorporates automatic memory of the last reading (viewable by pressing ON/OFF), automatic shut-off after about 8 minutes without use, low battery indicator and water resistance for brief immersions. It is powered by an included 1.5 V button cell (LR41/AG3), with an estimated battery life of 2 years or 2,500 measurements.
3. Technical Specifications
Features verified against the manufacturer’s technical data sheet (document FT-T19, p. 1-2, ver. 170922, reference 0658999):
| Characteristic | Specification |
|---|---|
| Reference / SKU | 0658999 / 658999 |
| EAN code | 8431785020099 |
| Product type | Digital clinical thermometer with flexible tip |
| Measurement range | 32.0 °C – 42.9 °C |
| Resolution | 0.1 °C |
| Accuracy | ± 0.1 °C (from 35.0 °C to 42.0 °C), at an ambient temperature of 18–28 °C |
| Low temperature indication | Below 32.0 °C: «L °C» |
| High temperature indication | Above 43.0 °C: «H °C» |
| Measurement time | Oral use: ~1 min · Rectal use: up to 1 min · Axillary use: 1–3 min |
| End-of-measurement beep | 10 long beeps in 10 seconds |
| Fever beep | 30 short beeps in 10 seconds if the temperature is ≥ 37.8 °C |
| Memory | Automatic — last reading via ON/OFF button |
| Auto power-off | After 8 minutes without use (± 2) |
| Power supply | 1 button cell 1.5 V AG3 / LR41 (included) |
| Battery life | 2 years or 2,500 measurements |
| Water resistance | Yes — brief immersion in water or alcohol (not prolonged) |
| Dimensions | 125 × 19 × 11 mm |
| Weight | Approx. 9.8 g (including the battery) |
| Colour | Green |
Presentation and contents
| Parameter | Detail |
|---|---|
| Presentation | Printed card hanging box with individual rigid transparent protective packaging |
| Contents | 1 flexible clinical thermometer + 1 button cell + instruction manual |
| Minimum sales unit | 400 units (box with 400 units, distributed in 20 inner boxes) |
Conditions of use and regulations
| Item | Reference |
|---|---|
| Operating conditions | Temperature 10–40 °C · Humidity 30–85 % RH |
| Storage conditions | Temperature −10 to +60 °C · Humidity 25–90 % RH |
| Intended use | Body temperature measurement by oral, rectal or axillary route |
| Regulatory classification | Medical device class IIa — Directive 93/42/EEC · CE certificate |
4. Equivalences and Cross-References
The analysed product (ref. Cahnos 0658999) is a digital clinical thermometer with flexible tip, range 32.0–42.9 °C, resolution 0.1 °C, accuracy ±0.1 °C, acoustic signal with fever alert, last reading memory and 1.5 V LR41/AG3 button cell. The following cross-references have been verified against each manufacturer’s official catalogue and website; they are not 1:1 interchangeable with the Cahnos reference (own marking and traceability), so they are classified as comparable by category:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Microlife | MT 1931 — flexible tip thermometer | MT 1931 | Comparable by category (not interchangeable 1:1) | Verified on Microlife’s official website: same measurement range (32.0–42.9 °C), accuracy ±0.1 °C (34–42 °C in Microlife versus 35–42 °C in the Cahnos model) and same 1.5 V LR41 button cell. Hypoallergenic flexible tip. |
| Prim | Flexible digital thermometer MT519 | MT519 (EAN 8426680986601) | Comparable by category (not interchangeable 1:1) | Verified in the brand’s official catalogue and authorised distributors: axillary and sublingual measurement, flexible tip ideal for children, accuracy ±0.1 °C between 32 °C and 42.9 °C and last measurement memory. Usually distributed in a 12-unit display. |
| Gima (Gima S.p.A.) | Digital thermometer BL1 – large display | 25553 (EAN 8023279255539) | Comparable by category (not interchangeable 1:1) | Verified in Gima’s official catalogue (medical device class IIa): flexible tip, waterproof, large backlit display, range 32.0–42.9 °C and accuracy ±0.1 °C; it is powered by a 3 V button cell (CR2032), compared to the 1.5 V LR41/AG3 of the Cahnos model. |
There is no equivalence table validated by the manufacturer that authorises the direct cross-reference of reference 0658999 with the models mentioned; consult the technical department before using this reference in tenders or replacing a unit in service. The market also offers homologous families of flexible-tip digital thermometers from brands such as Medisana, boso, CA-MI, Sanomed or LH, whose codes must be verified field by field (range, accuracy, acoustic signal, fever alert and battery) in their official datasheet before any replacement.
5. Selection tips and variants of interest
Select this model with a flexible tip when patient comfort is a priority: paediatrics, geriatrics, frequent axillary and sublingual measurements, or patients who reject rigid tips. For classic spot temperature checks, the catalogue offers the rigid-tip digital thermometer (ref. 0658057); for rapid non-contact triage at emergency department entrances or centres, consider the non-contact infrared thermometer (ref. 658073), and for volume needs refer to reference 1371002. Remember that this model is powered by a 1.5 V button cell in LR41/AG3 format: at Cahnos you will find the replacement in the Duracell 392/384 battery (ref. 0385038 / SKU 385038) and in the Maxell SR41 392 (ref. 0018008). To preserve accuracy, clean the tip with warm soapy water or an alcohol solution with brief immersion (the device is water-resistant, not suitable for prolonged submersion), do not boil the device, store it in its protective case and, in professional environments, periodically verify its calibration against a reference standard.