Description
1. Commercial Introduction
The reusable neonatal SpO2 pulse oximetry probe ref. 35107 is the ideal replacement and maintenance sensor for the company’s pulse oximetry equipment in units that care for the smallest patients. Designed for neonates from 3 to 10 kg, it allows continuous and non-invasive monitoring of oxygen saturation (SpO2) and pulse rate in neonatology, paediatrics, NICU, delivery rooms, clinics and medical transport. Being reusable, it offers a lower cost per patient compared to disposable probes and is the practical solution to always have an operational replacement sensor. It is sold per unit (1 pc) and the sale is made; our technical-commercial team will advise you on availability and conditions for institutional orders. For large orders you can request a quote.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin through the differential absorption of red and infrared light across the capillary bed. The probe incorporates the emitters and the photodetector in a flexible assembly that adapts gently to the neonate’s foot or hand, transmitting the plethysmographic signal to the monitor, which calculates and displays the SpO2 value and pulse rate in real time.
This reference is sized for the neonatal range of 3 to 10 kg, with an application point adapted to the newborn’s anatomy that minimises the risk of pressure injuries and reduces motion artefacts. It is a reusable probe: it must be cleaned and disinfected between patients following the manufacturer’s instructions and the centre’s protocol.
Important: the probe is supplied without a cable. To connect it to the equipment, the corresponding extension cable is required depending on the pulse oximeter used (see compatibility table).
3. Technical Specifications
| Product data | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040101352 |
| Available references | Description | Sales unit |
|---|---|---|
| 35107 | Reusable neonatal SpO2 probe 3-10 kg (this item) | 1 pc |
| Catheter features | Specification |
|---|---|
| Manufacturer reference | 35107 |
| Product type | Reusable neonatal SpO2 pulse oximetry probe |
| Patient population | Neonates 3 to 10 kg |
| Use | Reusable |
| Measured parameters | Oxygen saturation (SpO2) and pulse rate |
| Compatible equipment | Pulse oximeters Ref. 32902, 35100-1 and 35151-2 |
| Required cable (not included) | For equipment 35100-1: cable ref. 35108 · For equipment 32902: cable ref. 32917 |
4. Equivalences and Cross-References
This probe corresponds to reference 35107, verified in the manufacturer’s catalogue; no validated equivalence table has been found in reliable sources confirming 1:1 interchangeability with SpO2 sensors from other manufacturers (Nonin, Masimo, Nellcor, etc.), since compatibility depends on the connector and the electronic protocol of each device. In the event of any substitution in tenders or equipment fleets, always verify the exact brand and model with the technical department of Cahnos.
Within the pulse oximetry accessories range itself, the following related references are identified:
| Reference | Description | Related items |
|---|---|---|
| 35105 | Reusable adult SpO2 probe >40 kg | Same family (other population, not interchangeable) |
| 35106 | Reusable paediatric SpO2 probe 10-40 kg | Same family (other population, not interchangeable) |
| 35109 | Disposable neonatal/adult SpO2 probe | Single-use variant |
| 35108 | SpO2 extension cable (2 m) for equipment 35100-1 | Required cable for 35107 with 35100-1 |
| 32917 | Extension cable for equipment 32902 | Required cable for 35107 with 32902 |
5. Selection tips and variants of interest
Check the exact model of your pulse oximeter before placing the order: ref. 35107 is the one indicated for equipment Ref. 32902, 35100-1 and 35151-2. Remember that the probe requires a connection cable: request ref. 35108 if you work with the 35100-1 series, or ref. 32917 if you work with equipment 32902 (not included in the probe supply).
Always select the probe according to the patient’s weight range: for neonates from 3 to 10 kg this reference is suitable; for the paediatric population (10-40 kg) the catalogue offers probe ref. 35106 and for adults probe ref. 35105. As it is a reusable sensor, establish a cleaning and disinfection protocol between patients and periodically check the cable and the contact area to ensure stable readings. Contact the technical-commercial team of Cahnos to confirm compatibility with your equipment fleet, availability and conditions for volume orders.