Replacement Removable Finger Probe for Wrist Pulse Oximeter Ref. 34340 | Removable SpO₂ Sensor – Ref. 34339 (SKU GM34339)

27,55 €

Replacement removable finger probe for the wrist pulse oximeter Ref. 34340. Original part that allows you to replace or have a second unit of the device’s removable SpO₂ sensor, restoring non-invasive monitoring of oxygen saturation (SpO₂) and pulse rate in adult patients, both at home and in clinical settings and sports use. Original replacement, easy-to-place forceps-type design, reliable reading and designed for long-term monitoring. Class II A medical device (CND Z1203020408), sales unit 1 pc, compatible exclusively with the wrist pulse oximeter with software Ref. 34340; not suitable for paediatric use. For large orders you can request a quote: consult our technical-commercial team at Cahnos for terms and availability.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM34339

Description

1. Commercial Introduction

This removable finger probe is the original replacement (ref. 34339) for the wrist pulse oximeter with software Ref. 34340. It is designed as a spare part to replace the standard sensor when it deteriorates through continuous use or to have an additional unit that allows rotation between patients without interrupting monitoring. A reliable accessory of proven quality, ideal for consultations, primary care, home monitoring, diagnostic services and sports tracking.

2. Technical explanation of the device and the probe

The wrist pulse oximeter Ref. 34340 is worn like a watch and uses a removable finger probe to non-invasively measure oxygen saturation (SpO₂) and pulse rate (PR) by spectrophotometry: the sensor emits red and infrared light through the vascular bed of the finger and detects the differential absorption of haemoglobin according to its degree of oxygenation, transmitting the signal to the device for processing and display.

The device incorporates acoustic and visual alarm with adjustable limits, SpO₂ and pulse rate trend review function, selectable storage modes (1 group/1s, 1 group/4s and 1 group/8s) with up to 500 hours of recording in default mode, clock setting and date display, as well as integrated software to download all measurements to the PC. This removable finger probe, with a forceps-type design and easy placement, ensures comfortable grip and stable reading throughout monitoring.

3. Technical Specifications

Original replacement (spare) for the removable finger probe of the wrist pulse oximeter Ref. 34340. Below are the verified data from the manufacturer’s catalogue:

Field Specification
Manufacturer GIMA
Sales unit 1 pc
Device type Medical device (Medical device)
Device class II A
CND Z1203020408
GMDN 36087
EAN 6941900602793
Characteristic Specification
Manufacturer reference 34339
SKU Cahnos GM34339
Product type Removable finger probe – replacement
Sensor type Removable forceps-type finger probe
Compatibility Wrist pulse oximeter with software Ref. 34340
Population Adult (not suitable for paediatric use)
Nature Replacement (spare), reusable
Measured parameters Oxygen saturation (SpO₂) and pulse rate (PR)

4. Equivalences and Cross-References

Reference 34339 is the original manufacturer code for the removable finger probe of the wrist pulse oximeter 34340, marketed at Cahnos under SKU GM34339. There is no equivalence table validated by the manufacturer confirming 1:1 interchangeability with sensors from other brands, as compatibility depends on the connector and the device’s own configuration; before replacing any sensor with a third-party one, always check the exact make and model of your pulse oximeter.

Within the range of pulse oximetry accessories distributed by Cahnos, you can consult other SpO₂ probes from the same family as a comparative reference by category: replacement SpO₂ probe for PC-300 (ref. 35165), adult probe for pulse oximeters 35100/35101 (ref. 35105), adult finger clip for models 35152 and 35213 (ref. 35153) and D-type clip for monitors K12, K15 and Oxy 110 (ref. 35317).

5. Selection tips and variants of interest

Always confirm that your device corresponds to the wrist pulse oximeter Ref. 34340 before placing an order for this replacement. As it is a reusable sensor, follow the manufacturer’s cleaning and disinfection instructions between patients and avoid sharp bends in the cable to prolong its service life. It is recommended to keep one spare unit per pulse oximeter in use to minimise device downtime. For volume orders, service allocations or tenders, contact our technical-commercial team at Cahnos for terms, availability and delivery times. For large orders you can request a quote.

Additional information

Manufacturer

GIMA S.p.A.

Manufacturer reference

34339

Product type

Removable finger probe (replacement / spare) for pulse oximeter

Sensor type

Removable forceps-type finger probe

Compatibility

Wrist pulse oximeter with software ref. 34340

Population

Adult (not suitable for paediatric use)

Use

Reusable replacement

Measured parameters

SpO₂ and pulse rate (PR)

Device type

Medical device (Medical device)

CND code

Z1203020408

GMDN code

36087

EAN

6941900602793

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF