Description
1. Introduction
The replacement SpO₂ pulse oximeter catheter for adults (ref. 54417) is the original spare part your service needs to keep the brand’s pulse oximeters and vital signs monitors fully operational. With a 1.3 m cable, it offers the necessary length for comfortable patient placement without limiting mobility at the bedside, in emergency or consultation.
It is a class II A medical device supplied per unit (1 unit), intended for replacing worn or damaged catheters and for maintaining a rotation of consumables stock in hospitals, clinics, health centres and primary care services. As it is a spare part from the brand itself, it guarantees the expected compatibility and performance in the equipment.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate. The catheter emits light at two wavelengths (red and infrared) through the capillary bed and the photodetector collects the light absorbed by the tissues; the pulsatile component of the signal, generated by the arterial pulse, allows the percentage of saturated haemoglobin to be calculated.
This replacement catheter is sized for adult patients and connects to the corresponding monitor via its 1.3 m cable, facilitating continuous or spot recording of oxygen saturation. As an original spare part, it directly replaces the catheter supplied as standard with the equipment, maintaining measurement reliability.
3. Technical Specifications
The product characteristics correspond to the data recorded by Cahnos from the manufacturer’s catalogue (Product_DB.csv), without modifications to references or variants:
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 54417 |
| Catalogue description | SpO₂ catheter 1.3 m for adult – replacement |
| Patient population | Adult |
| Cable length | 1.3 m |
| Sales unit | 1 unit |
| Device type | Medical device (medical device) |
| Device class | II A |
| CND | C900301 |
| GMDN | 36087 |
| EAN | 6941900602823 |
4. Equivalences and Cross-References
The reference 54417 is the manufacturer’s own code for this adult SpO₂ catheter of 1.3 m as a replacement. There is no validated equivalence table that cross-references this reference with exact codes from other manufacturers on a 1:1 interchangeable basis.
Before replacing a catheter in equipment of other brands or models, it is essential to confirm the connector type, the electrical scheme and the communication protocol with the specific monitor installed at the centre. We always recommend indicating the brand and model of the monitor to our technical-commercial department to verify exact compatibility before placing the order.
5. Selection tips and variants of interest
Suitable replacement: this catheter is designed for adult patients; for paediatric or neonatal populations, the specific catheter for each weight range must be selected.
Prior verification: check the cable length and the connector compatible with your vital signs monitor before purchasing the replacement. Reference 54417 is the original 1.3 m adult replacement; do not modify or reuse damaged catheters, as this compromises signal quality.
Variants of interest: within the Cahnos catalogue you will find other pulse oximetry sensors and catheters for different populations and platforms (9-pin SpO₂ sensors for compatible monitors and families of reusable catheters), as well as pulse oximeters and multiparameter vital signs monitors. Consult our technical-commercial team for advice on the most suitable configuration for your equipment fleet and special conditions for volume purchases and institutions.