Description
1. Introduction
The adult clip-type SpO2 probe (ref. 34345) is the original replacement part your centre needs to keep the pulse oximeters Ref. 34341, 33698 and 34342 operational. Designed for adult patients, it allows the pulse oximetry sensor to be replaced or alternated quickly and reliably, extending the equipment’s service life without the need to purchase a new pulse oximeter. A practical solution for hospitalisation, emergency departments, consulting rooms, intrahospital transport and primary care.
2. Technical explanation
Pulse oximetry (SpO2) is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin through the differential absorption of red and infrared light across the capillary bed. This replacement probe integrates the emitter and photodetector in a clip-type clamp that is placed on the patient’s finger; the signal obtained is processed by the pulse oximeter, which displays the saturation value, pulse rate and, depending on the model, the plethysmographic waveform. As a reusable replacement part, it is intended for periodic sensor replacement without replacing the complete monitor.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 34345 |
| Product type | Replacement adult SpO2 probe (clip type) |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| CND | C900301 |
| GMDN | 36087 |
| EAN | 6941900608016 |
Compatible references (equipment)
| Compatible equipment | Compatibility note |
|---|---|
| Pulse oximeter Ref. 34341 | Up to serial number XCU052QF005021 |
| Pulse oximeter Ref. 33698 | Compatible |
| Pulse oximeter Ref. 34342 | Compatible |
4. Equivalences and Cross-References
Reference 34345 is the original code for this adult clip-type replacement probe. Within the Cahnos catalogue, other probes from the same family share the same functional category: the adult rubber probe (GM34351), the paediatric probe (GM34347) and the adult probe for PC-3000, VITAL and UP 7000 monitors (GM35135). No official equivalence table cross-referencing this reference with third-party manufacturer probes has been found in reliable sources; before replacing it with an alternative brand probe, confirm the connector and pulse oximetry protocol of your equipment with our technical-commercial department.
5. Selection tips and variants of interest
Check the model and serial number of your pulse oximeter: for model 34341, compatibility is guaranteed up to serial number XCU052QF005021; the replacement part also covers models 33698 and 34342. Keep at least one replacement part per active device, as the sensor is a frequently used accessory and having a spare probe avoids interruptions in monitoring. For the paediatric population, order the specific probe (GM34347); for other monitoring lines, consult the corresponding probe (e.g. GM34351 or GM35135). For large orders you can request a quote: contact the technical-commercial team at Cahnos for terms, availability and volume orders.





Reviews
There are no reviews yet.