Description
1. Commercial Introduction
The extension cable for SpO2 catheters (ref. 35318) is the spare accessory your facility needs to make oxygen saturation monitoring more flexible on the K12 and K15 series monitors. Designed and manufactured, this intermediate cable connects between the pulse oximetry catheter and the monitor, extending the working distance and facilitating sensor placement on the patient in settings such as outpatient clinics, emergency departments, hospitalisation wards, observation bays and intrahospital transport. As a spare part from the same brand, it maintains signal integrity and full compatibility with your equipment.
2. Technical Explanation
In SpO2 monitoring, the catheter (sensor) captures the optical signal from the capillary bed and transmits it to the monitor to calculate oxygen saturation and pulse rate. In many clinical configurations, the catheter cable length is insufficient to comfortably reach the measurement point, especially when the monitor is fixed to an infusion stand, at the head of the bed or on a transport trolley. This extension cable acts as an intermediate element between the catheter and the monitor, allowing greater freedom in placing the sensor on the patient’s hand, foot, earlobe or forehead. It is a passive connection component that does not alter the measurement and is essential as a spare part to keep the K12 and K15 monitors operational. It is supplied per unit and is classified as a class I medical device.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35318 |
| Reference Cahnos (SKU) | GM35318 |
| Sales unit | 1 unit |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | Z1203020280 |
| EAN | 6941900601864 |
Functional features
| Function | Extension cable for SpO2 catheters (spare part) |
|---|---|
| Compatibility | SpO2 catheters for K12 and K15 monitors |
| Use | Extending the catheter’s reach in oxygen saturation and pulse rate monitoring |
| Applications | Outpatient clinics, emergency departments, hospitalisation, observation bays and intrahospital transport |
4. Equivalences and Cross-References
Reference 35318 (SKU Cahnos GM35318) corresponds to the original extension cable, expressly intended for your K12 and K15 vital signs monitors. There is no official equivalence table validated by the manufacturer that cross-references this reference with extension cables from other brands; third-party extension cables for SpO2 catheters may have differences in connector, pinout and calibration, so they should only be replaced after confirming exact compatibility. To guarantee system integrity, it is recommended to use the original spare part.
5. Selection tips and variants of interest
Always verify that the SpO2 catheter of your K12 or K15 monitor is compatible with this extension cable before incorporating it into your equipment. This cable is sold per unit as a spare part: consider keeping a small safety stock in departments with high patient turnover, as continuous handling of cables is one of the most common causes of wear in monitoring systems. If you also need to expand monitoring points or renew sensors, consult the Cahnos catalogue for compatible spare SpO2 catheters and accessories for your vital signs monitor. For institutional orders, scheduled replenishments or tenders, contact the technical-commercial department of Cahnos for B2B conditions and compatibility confirmation.