We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable Infant SpO₂ Pulse Oximeter Sensor Compatible Nellcor | DB9 9-Pin Connector – Box of 25 Units | Ref. 18633

195,00 €

Disposable infant SpO₂ pulse oximeter sensor with 9-pin connector (DB9), compatible with Nellcor technology monitors (Nellcor/Oxismart protocol) for continuous non-invasive monitoring of oxygen saturation and pulse rate in infant patients (3–20 kg). Adhesive fixation adapted to paediatric anatomy, stable connection with bedside and multiparameter monitors, and reliable measurement with reference accuracy ≤ 3% in range 70–100%. Presentation in box of 25 units: the replacement solution with adjusted cost per unit, continuous stock and immediate availability for hospitals, paediatric clinics, emergency departments and paediatric ICU.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
18633

Description

1. Introduction

The infant 9-pin SpO₂ pulse oximeter sensor (Ref. 18633) is the reference consumable for services that monitor blood oxygenation in paediatric and infant patients with equipment compatible with Nellcor technology. Its 9-pin (DB9) connector ensures direct and secure integration with most bedside, transport and multiparameter monitors that use this standard, one of the most widely implemented in patient monitoring.

Presented in a box of 25 units, it is designed for hospitals, paediatric clinics, emergency departments and intensive care units that need to maintain a constant rotation of sensors with a competitive unit cost and immediate availability. As a single-use per patient sensor, it eliminates the risk of cross-contamination and simplifies service logistics.

2. Technical explanation

Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate by spectrophotometry: the sensor emits red light (660 nm) and infrared light (905 nm) through the vascular bed and detects differential absorption according to the degree of blood oxygenation. A photodetector quantifies the signal and the monitor calculates in real time the saturation percentage and pulse rate from the plethysmographic waveform.

The signal is transmitted to the monitor via the 9-pin (DB9) connector, which follows the electrical scheme of the Nellcor/Oxismart standard. This sensor is designed for infant patients, with a size, adhesive and fixation profile adapted to that population (profile comparable to the original reference of 3–20 kg), allowing comfortable and stable placement during continuous monitoring, even in patients with movement.

3. Technical Specifications

Parameter Specification
Management code 18633 (own SKU of Cahnos)
Sensor type Disposable SpO₂ pulse oximeter sensor for infant patients
Compatibility Infant Nellcor systems (Nellcor/Oxismart protocol)
Connection 9-pin (DB9)
Patient population Infant / paediatric (profile comparable to original reference 3–20 kg)
Applications Monitoring of blood oxygen saturation (SpO₂) and pulse rate
Contents Box of 25 units
Use Single-use per patient
Material Latex-free
Sterility Non-sterile
Areas of use Hospitals, paediatric clinics and monitoring services
SpO₂ measurement range 35–100 % (reference value of the Nellcor DB9 family; confirm in batch IFU)
SpO₂ accuracy ≤ 3 % in range 70–100 % (ISO 9919 / ISO 80601-2-61, reference value)
Pulse rate range 30–250 ppm (reference value; confirm in batch IFU)
Wavelengths Red light 660 nm / infrared 905 nm (reference value)
Storage Store in a dry place, protected from direct sunlight and extreme temperatures

Note: the range and accuracy values marked as reference come from technical data sheets of the same family of Nellcor sensors with DB9 connector; always confirm them on the labelling and IFU of the supplied batch.

4. Equivalences and Cross-References

SKU 18633 is Cahnos’s own management code. The following references have been checked against catalogues and public product documentation; none is interchangeable 1:1 with this sensor without prior verification, since the electrical scheme and communication protocol must be confirmed with the specific monitor installed at the centre.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Nellcor (Covidien/Medtronic) Oxisensor II – infant disposable adhesive sensor I-20 / I-20R Comparable by category (not interchangeable 1:1) Original sensor from the protocol manufacturer for infant patients (3–20 kg), 9-pin DB9 connector and Oxismart technology; sterile single use. Coding and electronics specific to the Nellcor standard. Confirm protocol (Oxisensor/OxiMax) with the monitor.
Nellcor (Covidien/Medtronic) Nellcor OxiMax – infant adhesive sensor MAX-I / MAX-I-I Comparable by category (not interchangeable 1:1) Infant sensor (3–20 kg) from the original manufacturer with OxiMax memory chip and 9-pin D-Sub connector; requires a monitor compatible with OxiMax technology. Verify protocol compatibility with each monitor before replacing.
Italian manufacture (class II B medical device) Disposable infant SpO₂ catheter compatible with Nellcor (Oxisensor protocol) GM33756 Comparable by category (not interchangeable 1:1) Disposable catheter for paediatric patients 3–20 kg with sterile packaging and 70 cm cable; compatible with Nellcor Oxisensor protocol monitors (not compatible with OxiMax). Presentation in box of 10 units. Same weight profile and connector as this sensor, with individual sterile packaging.

There is no equivalence table validated by the manufacturer that cross-references this sensor with codes from other brands interchangeably 1:1; consult with the technical department before using in a tender. The Nellcor family ear-clip sensors are another type of product, with a different geometry and application point, and should not be confused with this paediatric sensor.

5. Selection tips and variants of interest

Choice by population: within the same family of 9-pin Nellcor sensors, it includes the adult sensor (SKU 18631), paediatric sensor (SKU 18632), infant sensor (SKU 18633, this product) and adult/neonatal sensor (SKU 18634). If your department uses reusable sensors, consider the paediatric forceps compatible with Nellcor technology (Ref. AB78315040097) or, for neonates, the disposable Y-wrap sensor (Ref. AB78315040078).

Compatibility verification: although the connector is 9-pin (DB9), the Nellcor protocol has variants (Oxisensor/OxiMax). Always indicate the make and model of the monitor to confirm exact compatibility before placing the order.

Hygiene and storage: as it is a single-use sensor per patient, it eliminates the risk of cross-contamination. Do not reuse or reprocess the sensor; clean the outer surface with a soft, dry or slightly damp cloth, do not immerse or autoclave it. Store in a dry place, protected from direct sunlight and extreme temperatures.

Cost-effectiveness: the presentation in a box of 25 units reduces the cost per sensor and ensures continuous stock in high-turnover units. Consult our technical-commercial team for special B2B conditions by volume and supply contracts.

Additional information

Product type

SpO₂ pulse oximeter sensor (replacement for pulse oximeters)

Compatibility

Nellcor systems (Nellcor/Oxismart protocol)

Connection

9-pin (DB9 connector)

Patient population

Infant / paediatric (profile comparable to original reference 3–20 kg)

Presentation

Box of 25 units

Use

Single-use per patient

Reference spo2 range

35–100 % (confirm batch IFU)

Reference spo2 accuracy

≤ 3 % in range 70–100 % (confirm batch IFU)

Reference pulse range

30–250 ppm (confirm batch IFU)

Reference standard

ISO 9919 / ISO 80601-2-61 (family reference values)

Type

Disposable SpO₂ pulse oximeter sensor for infant patients

Population

Infant / paediatric (profile comparable to original reference 3–20 kg)

Application

SpO₂ and pulse rate monitoring in hospitals and clinics

Material

Latex-free

spo2 measurement range

35–100 % (Nellcor DB9 family reference value)

spo2 accuracy

≤ 3 % in range 70–100 % (ISO 9919 / ISO 80601-2-61)

Pulse rate range

30–250 ppm

Wavelengths

Red light 660 nm / infrared 905 nm

Esterilidad

Non-sterile

Reviews

There are no reviews yet.

Be the first to review “Disposable Infant SpO₂ Pulse Oximeter Sensor Compatible Nellcor | DB9 9-Pin Connector – Box of 25 Units | Ref. 18633”

Your email address will not be published. Required fields are marked *