Parker halogen ophthalmoscope – Diagnostic head with 24 lenses from -25 to +40 dioptres, 2.5 V halogen light (Ref. 31476 | SKU GM31476)

94,05 €

Parker halogen ophthalmoscope (ref. 31476) for fundus examination in ophthalmology practices, general medicine and primary care. It incorporates 2.5 V halogen light that faithfully reproduces the true colour of tissues and provides constant, long-lasting illumination, together with 24 colour-coded lenses (-25 to +40 dioptres; green for positive, red for negative) that guarantee excellent resolution in every examination. Its rubber brow rest protects the patient’s glasses from scratches and its illuminated lens dial allows the selected dioptre to be identified with total clarity. Supplied in a semi-rigid nylon bag with case and multilingual manual (GB, FR, IT, ES, PT, DE, GR, Arabic). Class I medical device. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM31476

You will also find it in

Description

1. Introduction

The Parker halogen ophthalmoscope is the reference tool for examining the posterior segment of the eye in ophthalmology practices, general medicine, primary care and emergency departments. It is a robust and reliable diagnostic head designed for daily use, offering 2.5 V halogen illumination with faithful colour reproduction of retinal tissue and 24-lens optics to cover a wide correction range. A simple, precise and durable instrument for completing ocular diagnosis quickly and safely.

2. Technical explanation

Direct ophthalmoscopy allows the fundus of the eye (retina, optic disc, macula and retinal vasculature) to be visualised through the pupil. This Parker head uses a 2.5 V halogen lamp whose light, with a colour temperature close to natural light, shows tissues in their true colour, facilitating the detection of abnormalities such as haemorrhages, exudates or oedemas. The lens dial incorporates 24 colour-coded lenses with a range of -25 to +40 dioptres (green for positive lenses and red for negative ones), allowing the ametropias of the patient and the examiner to be compensated with excellent resolution. The illuminated lens dial enables immediate reading of the selected dioptre, while the rubber brow rest prevents contact with and scratching of the patient’s glasses during examination.

3. Technical Specifications

Characteristic Specification
Manufacturer GIMA
Manufacturer reference 31476
SKU Cahnos GM31476
Product type Ophthalmoscope (diagnostic head)
Lighting Halogen light 2.5 V
Number of lenses 24 colour-coded lenses
Dioptre range -25 to +40 dioptres (green: positive, red: negative)
Ergonomics Anti-scratch rubber brow rest for glasses
Dioptre identification Illuminated lens dial
Presentation Semi-rigid nylon bag with case and multilingual manual (GB, FR, IT, ES, PT, DE, GR, Arabic)
Sales unit 1 unit
Device type Medical device
Device class I
CND Z12120114
GMDN 45084
EAN 8023279314762

4. Equivalences and Cross-References

The Parker halogen ophthalmoscope (ref. 31476, SKU GM31476) is part of the Parker diagnostic family, together with the halogen otoscope (ref. 31475, GM31475), the halogen operating otoscope (ref. 31474, GM31474), the halogen oto-ophthalmoscope set (ref. 31477, GM31477) and the Parker diagnostic sets (refs. 31471 and 31473). Direct 1:1 equivalents with ophthalmoscope heads from other manufacturers have not been verified in reliable sources; any comparison must be validated with the technical-commercial department of Cahnos.

5. Selection tips and variants of interest

This head is the ideal complement if you already have a compatible diagnostic handle from the Parker series or if you wish to add ophthalmological examination to your practice. If you also need otoscopic examination, consider the Parker halogen oto-ophthalmoscope set (GM31477), which integrates a handle, otoscope head and ophthalmoscope head in a case; as an alternative, the Parker diagnostic sets (GM31471 / GM31473) expand the instrument range with specula, laryngeal mirrors and ENT accessories. For institutional orders, tenders or questions about handle and head compatibility, contact the technical-commercial team at Cahnos. For large orders you can request a quote.

Additional information

Manufacturer reference

31476

EAN

8023279314762

CND code

Z12120114

GMDN code

45084

Lighting

Halogen 2.5 V

Number of lenses

24 colour-coded lenses

Dioptre range

-25 to +40 (green positive, red negative)

Ergonomics

Anti-scratch rubber brow rest

Dioptre identification

Illuminated lens dial

Presentation

Semi-rigid nylon bag, case and multilingual manual (GB, FR, IT, ES, PT, DE, GR, Arabic)

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Documentation

📄 DatasheetEnglish PDF