1. Commercial Introduction
The disposable ECG electrodes (reference 54314) are the replacement consumable designed for the Holter monitors of the series 54310, 54312 and 54313 from the same manufacturer. They are supplied in a box of 10 units and ensure accurate, reliable and comfortable cardiac monitoring for the patient during long-term continuous recordings.
Designed for cardiology departments, outpatient diagnostic units, medical practices and any service working with Holter systems, these single-use adhesive electrodes ensure an excellent cost per procedure ratio and reduce repetitions due to poor signal, streamlining the professional’s daily workflow.
2. Technical Explanation
The single-use surface electrodes are the interface between the patient’s skin and the Holter recorder: they capture the electrical activity of the heart and transmit it with the least possible distortion. The quality of the recording depends on three key factors: adhesion (the electrode must remain fixed throughout the test), conductivity (low skin-electrode contact impedance) and stability against patient movement.
These replacement electrodes incorporate a high-conductance conductive adhesive that maintains a stable and continuous electrical contact, essential conditions for obtaining a clean electrocardiogram without artefacts in Holter studies of 24, 72 or even 168 hours. Being a single-use and disposable product, the risk of cross-contamination between patients is completely eliminated, ensuring hygiene and traceability in each recording.
3. Technical Specifications
Product data
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 54314 |
| Sales unit | Box of 10 units |
| Device type | Medical device |
| Device class | I |
| CND | C020501 |
| EAN | 6971457741560 |
Main characteristics
| Parameter | Specification |
|---|---|
| Product | Replacement disposable ECG electrodes (single-use) |
| Compatibility | Holter ECG monitors Ref. 54310, 54312 and 54313 |
| Application | Continuous cardiac monitoring (Holter) of 24 h, 72 h and 168 h |
| Use | Single-use, disposable |
| Sales unit | Box of 10 units |
4. Equivalences and Cross-References
Reference 54314 is the official manufacturer code (.) of this replacement electrode, verified in the original Product_DB catalogue. It is part of the family of replacement consumables for the Holter ECG recorders Ref. 54310, 54312 and 54313, so its direct equivalence is with the equipment of that same series.
Also verified in authorised technical distribution, this product is consistently described as électrodes ECG jetables / elétrodes monouso de alta conducancia for Holter monitoring, presentation of 10 pieces. No 1:1 equivalence table validated by the manufacturer has been found that cross-references this code with codes from other electrode manufacturers; any comparison with third-party electrodes must be carried out field by field (type of adhesive, conductivity, connection to the Holter cable and compatibility with the equipment) and must be validated against its technical data sheet before any possible substitution. To ensure the perfect fit with your recorder, it is recommended to always confirm the exact model of your monitor before placing the order.
5. Selection tips and variants of interest
Verify the model of your monitor: these electrodes are the specific replacement for the Holter equipment Ref. 54310, 54312 and 54313. Check the reference of your recorder to ensure full compatibility.
Plan the replenishment: as it is a single-use and high-turnover consumable, maintain a minimum stock per monitoring station and rotate stock following the FIFO method. Keep the boxes closed in a dry and cool place.
Skin preparation: to optimise contact impedance and avoid artefacts, clean and dry the application area before placing the electrode, avoiding creams or gel residues from previous recordings.