We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

24 h Wearable ECG Holter Recorder Dynamic ECG Recorder – Single-channel, Bluetooth and AI ECG Analysis Software (Ref. 54310)

228,00 €

24-hour wearable ECG Holter recorder (ref. 54310): single-channel device (one lead) weighing only 18 g with ergonomic design and flexible material, designed to measure, review and store the ECG of adult patients at home or in the healthcare environment. It displays the ECG trace, heart rate, battery level and charging status on its 0.49” screen. It detects abnormal cardiac rhythms and transmits the data to the smartphone via Bluetooth, with the free ViHealth app and AI ECG analysis software for real-time monitoring (home use); it also includes the optional AI ECG Tracker software for professional use (ref. 54315). It is supplied with a charging cable, 10 disposable ECG electrodes (3.5 mm) and a multilingual manual. Rechargeable lithium battery with up to 168 h of battery life and charging in 2 hours.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM54310

Description

1. Wearable ECG recorder for continuous 24 h monitoring

The Dynamic ECG Recorder 24 H (ref. 54310) is an ambulatory electrocardiographic recorder of the wearable type, designed to measure, review and store ECG data from adult patients both at home and in a healthcare setting. Its ultra-lightweight and ergonomic design, weighing just 18 g with flexible material, allows the patient to maintain their daily routine while the device continuously records the electrical activity of the heart for 24 hours, making it the ideal solution for cardiology clinics, home care, telemedicine services and cardiovascular follow-up programmes.

2. Technical explanation of the equipment

This single-lead (single-channel) Holter recorder captures the electrocardiographic signal via adhesive electrodes placed on the chest and processes it internally with a sampling frequency of 250 Hz and a precision of 16 bits, offering a frequency response of 0.67 to 40 Hz suitable for detecting abnormal cardiac rhythms. The device displays on its 0.49” screen the real-time ECG trace, heart rate, battery level and charging status, and can store up to 10 complete measurements in its internal memory.

Data transmission is carried out via Bluetooth to the smartphone, where the free app ViHealth and the AI ECG analysis software allow real-time ECG monitoring in the home setting: the software manages the data, displays it, stores it, prints it and generates detailed automatic PDF reports that can be shared with the physician for assessment and diagnosis (it does not include a diagnostic or editing function). For professional environments, the system supports the optional software AI ECG Tracker (ref. 54315).

3. Technical Specifications

Main characteristics

  • Wearable ECG recorder for adults, for use at home or in a healthcare setting.
  • 0.49” screen with ECG trace, heart rate, battery and charging status.
  • Only 18 g: ergonomic design with flexible material.
  • Monitoring of abnormal cardiac rhythms.
  • Data transmission to the smartphone via Bluetooth.
  • Free ViHealth app and AI ECG analysis software (home use).
  • Optional AI ECG Tracker software for professional use (ref. 54315).

Technical specifications

Parameter Value
Measurement method Adhesive electrodes (electrode pads)
Leads Single-channel (single-lead)
Input impedance ≥ 10 MΩ, 10 Hz
CMRR ≥ 60 dB
Frequency response 0.67 ~ 40 Hz
Sampling frequency 250 Hz
Sampling precision 16 bits
Memory Up to 10 measurements
Power supply Rechargeable lithium battery 3.8 V DC, 240 mAh
Battery life 168 h
Weight-bearing time 2 hours
Size – Weight 100 × 23 × 10 mm – < 20 g (with battery)
Protection Type BF, IP22

Scope of delivery

  • Charging cable.
  • 10 disposable ECG electrodes (3.5 mm).
  • AI ECG analysis software.
  • Multilingual manual (ES, FR, IT, DE, GB).

Product data

Manufacturer GIMA
Sales unit 1 unit
Device type Medical device (medical device)
Device class II A
CND Z12050403
GMDN 35162
EAN 6934440102656

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer that allows this reference to be cross-referenced with codes from other manufacturers. The reference 54310 (Dynamic ECG Recorder 24 H) is the catalogue’s own code; within the same family, the manufacturer offers as a professional option the AI ECG Tracker software (ref. 54315), a direct complement to this recorder for the professional field. Any comparison with Holter systems from other brands must be verified field by field (number of leads, sampling frequency, battery life, memory, connectivity and analysis software) against the technical data sheet of each device before considering a replacement.

5. Selection tips and variants of interest

This recorder is intended for ambulatory cardiac monitoring over 24 h in adult patients, with dual use: home patient monitoring (ViHealth app and AI ECG software) or professional monitoring if the AI ECG Tracker software (ref. 54315) is incorporated. For services requiring longer recordings or multiple ECG channels with pacemaker detection, Cahnos offers long-duration 3-channel Holter recorders (e.g. ref. 30.90-9543). Remember to replenish the compatible disposable 3.5 mm ECG electrodes included in the initial supply and plan the charging cycles of the lithium battery (full charge in 2 hours) to keep the device continuously operational. For institutional orders, supplies or tenders, consult the technical-commercial department of Cahnos to confirm references and volume conditions.

Additional information

Manufacturer reference

54310

EAN

6934440102656

Product type

Wearable ECG Holter recorder (medical device)

CND code

Z12050403

GMDN code

35162

Measurement method

Adhesive electrodes (electrode pads)

Leads

Single-channel (single-lead)

Input impedance

≥ 10 MΩ, 10 Hz

CMRR

≥ 60 dB

Frequency response

0.67 ~ 40 Hz

Sampling frequency

250 Hz

Sampling precision

16 bits

Memory

Up to 10 measurements

Display

0.49”

Battery

Rechargeable lithium, 3.8 V DC, 240 mAh

Battery life

168 h

Weight-bearing time

2 hours

Weight

18 g; < 20 g with battery

Dimensions

100 × 23 × 10 mm

Protection

Type BF, IP22

Connectivity

Bluetooth (data transmission to smartphone)

Software

Free ViHealth app + AI ECG analysis software (home use); optional AI ECG Tracker for professional use (54315)

Scope of delivery

Charging cable, 10 disposable ECG electrodes (3.5 mm), AI ECG analysis software and multilingual manual (ES, FR, IT, DE, GB)

Application

Measurement, review and storage of adult ECG at home or in a healthcare setting

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “24 h Wearable ECG Holter Recorder Dynamic ECG Recorder – Single-channel, Bluetooth and AI ECG Analysis Software (Ref. 54310)”

Your email address will not be published. Required fields are marked *